Laserfiche WebLink
SIMPSON HGAMV <br />W/ <br />(4) 1/4"xl 1/2" SDS <br />SCREWS <br />TO BLOCKING & (1 <br />1 /4"X2 3/4" <br />TITEN TO CMU <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND <br />FASTENERS. (MIN. FIRST 4 BAYS) <br />SEE STRUCTURAL NOTES AND NAILING TOENAIL w/ <br />SCHEDULE FOR SHEATHING DETAIL-7 (2)16d NAILS —� <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />MAX. 9" AND FASTENERS. (MIN. FIRST 4 BAYS) <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 BACKNAIL w/ (2)16d NAILS —� <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />MAX 9" SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS) <br />IF >9" SEE 10/S5 <br />BACKNAIL w/ (2)16d NAILS <br />SEE STRUCTURAL NOTES AND NAILING <br />SCHEDULE FOR SHEATHING DETAIL ��\ <br />' 45°± / <br />45° ± SEE STRUCTURAL <br />NOTES AND NAILING <br />2x4 CRO BRACE SCHEDULE FOR <br />APPROX. 8" FROM SHEATHING DETAIL 2x4 KICKER 2x8 SYP#2 "L" BRACE TO <br />RIDGE FASTENED AT @ 8'-0" 0/C. EXTEND AT LEAST 90% OF <br />"L" BRACE TO EXTEND 2x4 CROSS BRACE WEB LENGTH & NOTCH AT ' <br />EACH JOINT W/ (3) @ AT LEAST 90% OF WEB APPROX. 8" FROM BOTTOM CHORD (SEE TABLE) <br />& (2)10d TOE NAILS @ . LENGTH (SEE TABLE) RIDGE FASTENED AT <br />EA. END @ 48" O.C. SIMPSON H2.5A w/ (10) 8d <br />2x8 P.T. GABLE TRUSS EACH JOINT w/ (3)10d & <br />SILL (2)1Od TOE NAILS @ EA. FROM LEDGER TO <br />1/2" CDX PLYWOOD OR END •� BLOCKING <br />' 7/16" OSB SHEATHING GYPSUM WALL BOARD <br />ATTACHED W/ 10d GABLE TRUSS <br />NAILS 6" O.C. EDGES 2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST ' <br />@ 1/2"CDX PLYWOOD OR 7/16" <br />AND 12" O.C. FIELD (4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />10dX3" @ 3" 0/C CORD ATTACHED W/ (2)16d TOENAILS OSB SHEATHING ATTACHED <br />THROUGH CHORD 2"x4" LEDGER (MATCH BOTTOM CHORD w! 10d NAILS @ 6 O.C. <br />na INTO 2" 6" P T PLATE SLOPE OF ADJACENT SCISSOR TRUSS) EDGES AND 12" O.C. FIELD <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />MAX. 9" <br />UNSUPPORTED, BACKNAIL w/ (2)16d NAILS <br />IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND <br />DETAIL <br />SCHEDULE FOR SHEATHING <br />DOUBLE TOP PLATE 2"x4" CROSS BRACE <br />2x4 CROSS BRACE APPROX. 8" APPROX. 8" FROM <br />FROM RIDGE FASTENED AT RIDGE FASTENED AT <br />EACH JOINT w/ (3)1 Od & (2)1 Od EACH JOINT w/ (3) <br />TOE NAILS @ EA. END 10d & (2)10d TOE <br />2x FRAME WALL (SEE WALL NAILS @ EA. END <br />SECTION FOR SIZE & SPACING) 2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE <br />OSB SHEATHING ATTACHED FIRST (4) ROWS OF <br />W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. <br />AND 12" O.C. FIELD END TYP. TOP & <br />(2) 16d NAILS BOTTOM ATTACHED <br />W/ (2)16d TOENAILS <br />x 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING <br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L" BRACE HERE <br />FASTEN WITH 1 Odx3" @ 4" O/C SPACED WEEP SCREED THE FIRST (4) ROWS OF TRUSSES 2x4 "T" ON TOP OF PANEL <br />1/2" x 8" "J" BOLT @ 48" 0 C <br />(2)16d <br />INSTALLED PER MANUF. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM SIMPSON HGA1OKT w/ (4)1/4"x1 1/2" SIDS SCREWS TO <br />@ 48" O.C. BLOCKING, FASTEN WITH <br />SIMPSON META12 w/ (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. <br />MOISTURE BARRIER 1Odx3" @ 4" O/C <br />1!2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS MOISTURE BARRIER <br />SIMPSON META12 w/ (7) <br />NOTE: IF EMBEDDED 10dx1 1/2" NAILS AT EA. & (4)1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24,, GABLE WEB SECTION 2 <br />WEB, USE MSTAM36 w/ (7) �O.C.MAX)WMIN,4" <br />1Od NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK <br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5 <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />-REFER TO DETAIL J N N AND FASTENERS. (MIN. FIRST 4 BAYS) <br />ON SHEET S5 FOR <br />X-BRACING, AND TOP r " SEE STRUCTURAL <br />CHORD BLOCKING - NOTES AND NAILING <br />INFORMATION `° SCHEDULE FOR <br />1 1 SHEATHING DETAIL BACKNAIL w/ <br />1/ " (2)16d NAILS <br />-WOOD TRUSSES co oo 2"x4" CROSS BRACE <br />-2x4 RAT RUN BRACING APPROX. 8" FROM <br />AT 24" O.C. ON TOP BRACING <br />1 1 2" % RIDGE FASTENED AT <br />EACH JOINT w/ (3) <br />BOTT. CHORD FOR 4 10d & (2)10d TOE <br />TRUSS SPANS NAILS @ EA. END <br />ATTACHED W/ 2 -16d <br />AT EA. TRUSS JOINT " �� O (3) 2" x 4" LAMINATIONS W/ (1) ROW " " 2x4 PANEL BLOCKING <br />(2) 2 x 4 LAMINATIONS W/ 1 ROW (3) 2 x 6 LAMINATIONS W/ (2) ROWS OF @ 48" O/C FOR THE (2)16d NAILS <br />2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS FIRST <br />2X4 L CKIN (D = 0.148 , L = 3) OR EQUAL (D = 0.207 , L = 41/2') OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (4) ROWS OF <br />O/CTRUSSES FROM EA. <br />TOENAILS @ EA. END NOTES: END TYP. TOP & <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL BOTTOM ATTACHED <br />' MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS <br />-ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />SPACE AS SHOWN FOR 3 PLY <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 1 O/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 1 Od NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />•2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />1Odx3" @ 4" O/C <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />71 <br />10d NAILS @ 4" <br />O,C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. 16d NAIL <br />L BRACE ATTACHED <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB J <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0/C GABLE TRUSS <br />TRUSS VERTICAL <br />J <br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE SIMPSON SPZ w/ (12) 10d <br />SLOPE OF ADJACENT TRUSS NAILS AT EACH STUD FASTENED WITH 3 <br />) STUD WALL (SEE TYP. SEC.) ( ) <br />SECTION 16d PER SIDE <br />3 SECTION 4 SCISSOR GABLE "T" BRACE 7 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5 <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 1Od NAILS @ 6" O.C. <br />E ES AND 12" O.C. FIELD <br />14CJACK TRUSS <br />SEE PLAN FOR <br />CONNECTION <br />OF THE LAST LAMINATION ( ) 2x4 "T' ON TOP OF PANEL <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH L- 2x4 BLOCKING W/ <br />EXT. WALL CONN. COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF 1Odx3 @ 4 O/C (2)12d TOENAILS <br />NON -LOAD BEARI G LOCATIONrD B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION <br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT—UP COLUMNS 8 9 <br />ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />CROSS BRACING DETAIL <br />S5 <br />12 <br />6.9 MAX. <br />12" <br />1INIMUM 2x <br />'ROSS BRACING <br />SEE PLAN FOR <br />OCATIONS) TOENAIL <br />(2)16d NA <br />(2)16d PER <br />JOINT <br />7"YA" RAIN SFF RA/Sri <br />SCALE: N.T.S. <br />S5 <br />:E RSH SCHEDULE <br />IR ATTACHMENT <br />:4 #2 SYP BLK'G @ 16" O.C. <br />10d x 0.131" <br />)ENAILS EA, SIDE <br />)NT. 2x4 #2 SYP w/ 1 Od <br />XO.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL 10 <br />SCALE: N.T.S. S5 <br />GABLE TRUSS <br />1" BRACE W/ 10d @ 4" O.C. <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />I all a �II fl allm \ lI II Ik 4 <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S. <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C <br />WOOD TRUSSES <br />SIMPSON HGAMIOKTAw/ (4) <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"X2 3/4" <br />TITEN TO CMU <br />2 x 4 BLOCKING w/ (2)1 Od <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />BRACING w/ (3)1 Od x 3" AT = <br />• EACH CONN. @ 24" O/C <br />MOISTURE BARRIER <br />BOND BEAM <br />MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. (� NON -LOAD <br />BEARING LOCATION (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />MAX. 9" <br />UNSUPPORTED, BACKNAIL w/ (2)16d NAILS <br />IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND <br />DETAIL <br />SCHEDULE FOR SHEATHING <br />DOUBLE TOP PLATE 2"x4" CROSS BRACE <br />2x4 CROSS BRACE APPROX. 8" APPROX. 8" FROM <br />FROM RIDGE FASTENED AT RIDGE FASTENED AT <br />EACH JOINT w/ (3)1 Od & (2)1 Od EACH JOINT w/ (3) <br />TOE NAILS @ EA. END 10d & (2)10d TOE <br />2x FRAME WALL (SEE WALL NAILS @ EA. END <br />SECTION FOR SIZE & SPACING) 2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR 7/16" @ 48" O/C FOR THE <br />OSB SHEATHING ATTACHED FIRST (4) ROWS OF <br />W/ 10d NAILS @ 6" O.C. EDGES TRUSSES FROM EA. <br />AND 12" O.C. FIELD END TYP. TOP & <br />(2) 16d NAILS BOTTOM ATTACHED <br />W/ (2)16d TOENAILS <br />x 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING <br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L" BRACE HERE <br />FASTEN WITH 1 Odx3" @ 4" O/C SPACED WEEP SCREED THE FIRST (4) ROWS OF TRUSSES 2x4 "T" ON TOP OF PANEL <br />1/2" x 8" "J" BOLT @ 48" 0 C <br />(2)16d <br />INSTALLED PER MANUF. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM SIMPSON HGA1OKT w/ (4)1/4"x1 1/2" SIDS SCREWS TO <br />@ 48" O.C. BLOCKING, FASTEN WITH <br />SIMPSON META12 w/ (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. <br />MOISTURE BARRIER 1Odx3" @ 4" O/C <br />1!2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS MOISTURE BARRIER <br />SIMPSON META12 w/ (7) <br />NOTE: IF EMBEDDED 10dx1 1/2" NAILS AT EA. & (4)1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24,, GABLE WEB SECTION 2 <br />WEB, USE MSTAM36 w/ (7) �O.C.MAX)WMIN,4" <br />1Od NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK <br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5 <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />-REFER TO DETAIL J N N AND FASTENERS. (MIN. FIRST 4 BAYS) <br />ON SHEET S5 FOR <br />X-BRACING, AND TOP r " SEE STRUCTURAL <br />CHORD BLOCKING - NOTES AND NAILING <br />INFORMATION `° SCHEDULE FOR <br />1 1 SHEATHING DETAIL BACKNAIL w/ <br />1/ " (2)16d NAILS <br />-WOOD TRUSSES co oo 2"x4" CROSS BRACE <br />-2x4 RAT RUN BRACING APPROX. 8" FROM <br />AT 24" O.C. ON TOP BRACING <br />1 1 2" % RIDGE FASTENED AT <br />EACH JOINT w/ (3) <br />BOTT. CHORD FOR 4 10d & (2)10d TOE <br />TRUSS SPANS NAILS @ EA. END <br />ATTACHED W/ 2 -16d <br />AT EA. TRUSS JOINT " �� O (3) 2" x 4" LAMINATIONS W/ (1) ROW " " 2x4 PANEL BLOCKING <br />(2) 2 x 4 LAMINATIONS W/ 1 ROW (3) 2 x 6 LAMINATIONS W/ (2) ROWS OF @ 48" O/C FOR THE (2)16d NAILS <br />2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS FIRST <br />2X4 L CKIN (D = 0.148 , L = 3) OR EQUAL (D = 0.207 , L = 41/2') OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (4) ROWS OF <br />O/CTRUSSES FROM EA. <br />TOENAILS @ EA. END NOTES: END TYP. TOP & <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL BOTTOM ATTACHED <br />' MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS <br />-ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />SPACE AS SHOWN FOR 3 PLY <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 1 O/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 1 Od NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />•2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />1Odx3" @ 4" O/C <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />71 <br />10d NAILS @ 4" <br />O,C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. 16d NAIL <br />L BRACE ATTACHED <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB J <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0/C GABLE TRUSS <br />TRUSS VERTICAL <br />J <br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE SIMPSON SPZ w/ (12) 10d <br />SLOPE OF ADJACENT TRUSS NAILS AT EACH STUD FASTENED WITH 3 <br />) STUD WALL (SEE TYP. SEC.) ( ) <br />SECTION 16d PER SIDE <br />3 SECTION 4 SCISSOR GABLE "T" BRACE 7 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5 <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 1Od NAILS @ 6" O.C. <br />E ES AND 12" O.C. FIELD <br />14CJACK TRUSS <br />SEE PLAN FOR <br />CONNECTION <br />OF THE LAST LAMINATION ( ) 2x4 "T' ON TOP OF PANEL <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH L- 2x4 BLOCKING W/ <br />EXT. WALL CONN. COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF 1Odx3 @ 4 O/C (2)12d TOENAILS <br />NON -LOAD BEARI G LOCATIONrD B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION <br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT—UP COLUMNS 8 9 <br />ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />CROSS BRACING DETAIL <br />S5 <br />12 <br />6.9 MAX. <br />12" <br />1INIMUM 2x <br />'ROSS BRACING <br />SEE PLAN FOR <br />OCATIONS) TOENAIL <br />(2)16d NA <br />(2)16d PER <br />JOINT <br />7"YA" RAIN SFF RA/Sri <br />SCALE: N.T.S. <br />S5 <br />:E RSH SCHEDULE <br />IR ATTACHMENT <br />:4 #2 SYP BLK'G @ 16" O.C. <br />10d x 0.131" <br />)ENAILS EA, SIDE <br />)NT. 2x4 #2 SYP w/ 1 Od <br />XO.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL 10 <br />SCALE: N.T.S. S5 <br />GABLE TRUSS <br />1" BRACE W/ 10d @ 4" O.C. <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />I all a �II fl allm \ lI II Ik 4 <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S. <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C <br />WOOD TRUSSES <br />SIMPSON HGAMIOKTAw/ (4) <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"X2 3/4" <br />TITEN TO CMU <br />2 x 4 BLOCKING w/ (2)1 Od <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />BRACING w/ (3)1 Od x 3" AT = <br />• EACH CONN. @ 24" O/C <br />MOISTURE BARRIER <br />BOND BEAM <br />MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. (� NON -LOAD <br />BEARING LOCATION (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />x 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING <br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"x6" P.T. SILL NOTCH "L" BRACE HERE <br />FASTEN WITH 1 Odx3" @ 4" O/C SPACED WEEP SCREED THE FIRST (4) ROWS OF TRUSSES 2x4 "T" ON TOP OF PANEL <br />1/2" x 8" "J" BOLT @ 48" 0 C <br />(2)16d <br />INSTALLED PER MANUF. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM SIMPSON HGA1OKT w/ (4)1/4"x1 1/2" SIDS SCREWS TO <br />@ 48" O.C. BLOCKING, FASTEN WITH <br />SIMPSON META12 w/ (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. <br />MOISTURE BARRIER 1Odx3" @ 4" O/C <br />1!2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS MOISTURE BARRIER <br />SIMPSON META12 w/ (7) <br />NOTE: IF EMBEDDED 10dx1 1/2" NAILS AT EA. & (4)1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION TRUSS VERTICAL WEB (24,, GABLE WEB SECTION 2 <br />WEB, USE MSTAM36 w/ (7) �O.C.MAX)WMIN,4" <br />1Od NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK <br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5 <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />-REFER TO DETAIL J N N AND FASTENERS. (MIN. FIRST 4 BAYS) <br />ON SHEET S5 FOR <br />X-BRACING, AND TOP r " SEE STRUCTURAL <br />CHORD BLOCKING - NOTES AND NAILING <br />INFORMATION `° SCHEDULE FOR <br />1 1 SHEATHING DETAIL BACKNAIL w/ <br />1/ " (2)16d NAILS <br />-WOOD TRUSSES co oo 2"x4" CROSS BRACE <br />-2x4 RAT RUN BRACING APPROX. 8" FROM <br />AT 24" O.C. ON TOP BRACING <br />1 1 2" % RIDGE FASTENED AT <br />EACH JOINT w/ (3) <br />BOTT. CHORD FOR 4 10d & (2)10d TOE <br />TRUSS SPANS NAILS @ EA. END <br />ATTACHED W/ 2 -16d <br />AT EA. TRUSS JOINT " �� O (3) 2" x 4" LAMINATIONS W/ (1) ROW " " 2x4 PANEL BLOCKING <br />(2) 2 x 4 LAMINATIONS W/ 1 ROW (3) 2 x 6 LAMINATIONS W/ (2) ROWS OF @ 48" O/C FOR THE (2)16d NAILS <br />2x4 BLOCKING @ 24" OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS FIRST <br />2X4 L CKIN (D = 0.148 , L = 3) OR EQUAL (D = 0.207 , L = 41/2') OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (4) ROWS OF <br />O/CTRUSSES FROM EA. <br />TOENAILS @ EA. END NOTES: END TYP. TOP & <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL BOTTOM ATTACHED <br />' MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS <br />-ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />SPACE AS SHOWN FOR 3 PLY <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 1 O/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 1 Od NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />•2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />1Odx3" @ 4" O/C <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />71 <br />10d NAILS @ 4" <br />O,C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. 16d NAIL <br />L BRACE ATTACHED <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB J <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0/C GABLE TRUSS <br />TRUSS VERTICAL <br />J <br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE SIMPSON SPZ w/ (12) 10d <br />SLOPE OF ADJACENT TRUSS NAILS AT EACH STUD FASTENED WITH 3 <br />) STUD WALL (SEE TYP. SEC.) ( ) <br />SECTION 16d PER SIDE <br />3 SECTION 4 SCISSOR GABLE "T" BRACE 7 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5 <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 1Od NAILS @ 6" O.C. <br />E ES AND 12" O.C. FIELD <br />14CJACK TRUSS <br />SEE PLAN FOR <br />CONNECTION <br />OF THE LAST LAMINATION ( ) 2x4 "T' ON TOP OF PANEL <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH L- 2x4 BLOCKING W/ <br />EXT. WALL CONN. COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF 1Odx3 @ 4 O/C (2)12d TOENAILS <br />NON -LOAD BEARI G LOCATIONrD B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION <br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT—UP COLUMNS 8 9 <br />ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />CROSS BRACING DETAIL <br />S5 <br />12 <br />6.9 MAX. <br />12" <br />1INIMUM 2x <br />'ROSS BRACING <br />SEE PLAN FOR <br />OCATIONS) TOENAIL <br />(2)16d NA <br />(2)16d PER <br />JOINT <br />7"YA" RAIN SFF RA/Sri <br />SCALE: N.T.S. <br />S5 <br />:E RSH SCHEDULE <br />IR ATTACHMENT <br />:4 #2 SYP BLK'G @ 16" O.C. <br />10d x 0.131" <br />)ENAILS EA, SIDE <br />)NT. 2x4 #2 SYP w/ 1 Od <br />XO.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL 10 <br />SCALE: N.T.S. S5 <br />GABLE TRUSS <br />1" BRACE W/ 10d @ 4" O.C. <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />I all a �II fl allm \ lI II Ik 4 <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S. <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C <br />WOOD TRUSSES <br />SIMPSON HGAMIOKTAw/ (4) <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"X2 3/4" <br />TITEN TO CMU <br />2 x 4 BLOCKING w/ (2)1 Od <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />BRACING w/ (3)1 Od x 3" AT = <br />• EACH CONN. @ 24" O/C <br />MOISTURE BARRIER <br />BOND BEAM <br />MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. (� NON -LOAD <br />BEARING LOCATION (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 1 O/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 1 Od NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />•2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />1Odx3" @ 4" O/C <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />71 <br />10d NAILS @ 4" <br />O,C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. 16d NAIL <br />L BRACE ATTACHED <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB J <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0/C GABLE TRUSS <br />TRUSS VERTICAL <br />J <br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE SIMPSON SPZ w/ (12) 10d <br />SLOPE OF ADJACENT TRUSS NAILS AT EACH STUD FASTENED WITH 3 <br />) STUD WALL (SEE TYP. SEC.) ( ) <br />SECTION 16d PER SIDE <br />3 SECTION 4 SCISSOR GABLE "T" BRACE 7 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5 <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 1Od NAILS @ 6" O.C. <br />E ES AND 12" O.C. FIELD <br />14CJACK TRUSS <br />SEE PLAN FOR <br />CONNECTION <br />OF THE LAST LAMINATION ( ) 2x4 "T' ON TOP OF PANEL <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH L- 2x4 BLOCKING W/ <br />EXT. WALL CONN. COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF 1Odx3 @ 4 O/C (2)12d TOENAILS <br />NON -LOAD BEARI G LOCATIONrD B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION <br />SEE TYP. WALL SECTION FOR SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT—UP COLUMNS 8 9 <br />ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />CROSS BRACING DETAIL <br />S5 <br />12 <br />6.9 MAX. <br />12" <br />1INIMUM 2x <br />'ROSS BRACING <br />SEE PLAN FOR <br />OCATIONS) TOENAIL <br />(2)16d NA <br />(2)16d PER <br />JOINT <br />7"YA" RAIN SFF RA/Sri <br />SCALE: N.T.S. <br />S5 <br />:E RSH SCHEDULE <br />IR ATTACHMENT <br />:4 #2 SYP BLK'G @ 16" O.C. <br />10d x 0.131" <br />)ENAILS EA, SIDE <br />)NT. 2x4 #2 SYP w/ 1 Od <br />XO.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL 10 <br />SCALE: N.T.S. S5 <br />GABLE TRUSS <br />1" BRACE W/ 10d @ 4" O.C. <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />I all a �II fl allm \ lI II Ik 4 <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S. <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C <br />WOOD TRUSSES <br />SIMPSON HGAMIOKTAw/ (4) <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"X2 3/4" <br />TITEN TO CMU <br />2 x 4 BLOCKING w/ (2)1 Od <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />BRACING w/ (3)1 Od x 3" AT = <br />• EACH CONN. @ 24" O/C <br />MOISTURE BARRIER <br />BOND BEAM <br />MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. (� NON -LOAD <br />BEARING LOCATION (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />CROSS BRACING DETAIL <br />S5 <br />12 <br />6.9 MAX. <br />12" <br />1INIMUM 2x <br />'ROSS BRACING <br />SEE PLAN FOR <br />OCATIONS) TOENAIL <br />(2)16d NA <br />(2)16d PER <br />JOINT <br />7"YA" RAIN SFF RA/Sri <br />SCALE: N.T.S. <br />S5 <br />:E RSH SCHEDULE <br />IR ATTACHMENT <br />:4 #2 SYP BLK'G @ 16" O.C. <br />10d x 0.131" <br />)ENAILS EA, SIDE <br />)NT. 2x4 #2 SYP w/ 1 Od <br />XO.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL 10 <br />SCALE: N.T.S. S5 <br />GABLE TRUSS <br />1" BRACE W/ 10d @ 4" O.C. <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />I all a �II fl allm \ lI II Ik 4 <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S. <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C <br />WOOD TRUSSES <br />SIMPSON HGAMIOKTAw/ (4) <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"X2 3/4" <br />TITEN TO CMU <br />2 x 4 BLOCKING w/ (2)1 Od <br />TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />BRACING w/ (3)1 Od x 3" AT = <br />• EACH CONN. @ 24" O/C <br />MOISTURE BARRIER <br />BOND BEAM <br />MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. (� NON -LOAD <br />BEARING LOCATION (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - 3'-0" <br />T-0" - 6'-O" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT W/ (4) 1/4"x1 1/2" SDS <br />tiviv i . u.nruva "- <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />61 WbUN SNZ W/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />✓9 <br />o <br />Cr <br />CORNERJACK <br />k <br />0. <br />QU <br />Er <br />w <br />z <br />O <br />U <br />HIP FRAMING REFERENCE PLAN <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. <br />1111 <br />2�- <br />NOTE: ZTOP CHORD 2x4 #2 SYP BRACING <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />ZBOTTOM <br />@ 16" O.C. MAX. FOR FIRST (4) <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />BAYS <br />THAT MY BE REQUIRED <br />CHORD GABLE END BRACING <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />@ 4'4" O.C. MAX. FOR FIRST (4) BAYS <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />L <br />En <br />I11 hw/t,��¢�� <br />���yy����4iZlI <br />Cj <br />U <br />�O� C:" <br />•,` <br />B <br />C"'i��� <br />0. . <br />FL5 <br />...... <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />�1 <br />F <br />E ti <br />O (rOj tp h �k <br />C <br />O N N v J <br />C J It <br />M <br />9n°0� ac"a <br />LL <br />�MO� u. a Y <br />Q <br />� <br />JLLu- a 3 <br />o <br />�0 <br />Z <br />t <br />W <br />8 <br />5Nco M O <br />°' ¢ <br />LL Z <br />U rn .1 <br />a <br />W o <br />N Mz° CD <br />06 <br />Z <br />W <br />C] ❑ ❑ <br />z N c+r <br />o$ <br />z to <br />z <br />J <br />N <br />N <br />V O <br />— LL <br />N <br />W <br />—� <br />O <br />V) <br />�U) <br />�_ s <br />fz <br />ago <br />W � <br />pEp <br />L O <br />I <br />yl1 <br />O N <br />Cn <br />Q - <br />�0 <br />• <br />N O <br />4m <br />oCAD <br />w <br />M <br />o 0 <br />0 <br />Z <br />`; o <br />0® <br />14 <br />CL o <br />C 8 <br />I.EiF- <br />wz <br />oa <br />cc (6 <br />U <br />& 8 <br />O <br />O� <br />O <br />N <br />¢z <br />g <br />WZ <br />H <br />� _ <br />_ <br />U <br />o <br />zz <br />z <br />co N <br />ym <br />QW <br />oa <br />go <br />W <br />U <br />LL <br />�o <br />a <br />OW <br />r� <br />z <br />o <br />w� <br />�~ <br />>° <br />c0 <br />d <br />zl¢ <br />a <br />VO c$ <br />N O <br />> Lo <br />a� <br />nL' <br />W <br />m <br />0 <br />.> <br />C) <br />0 <br />T <br />0 <br />' <br />0 <br />O <br />n <br />r) <br />O <br />m <br />O <br />E N <br />.T� <br />N <br />00 <br />T- <br />... V <br />r <br />0) <br />m <br />F T <br />M <br />Z <br />z <br />E <br />E <br />aCU <br />'a w <br />€ <br />d <br />4.; <br />U -1 <br />Q p <br />JOB <br />NO: <br />20-8083 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S5 <br />