ELECTRICAL SPECIFICATION <br />150A/2 <br />LCINDOOR <br />PANEL CENTER <br />NOTES: <br />112, 1 <br />V <br />10 #14 copper to lights 8 outlets <br />I` 1 <br />ELECTRICAL CONTRACTOR <br />NEMA 1 10 #12 copper to 20 amp ckts <br />ISO AMP/ <br />I R <br />MUST VERIFY WITH THE <br />2 0AMP <br />#1 <br />`q <br />V <br />SPECIFICATIONS FOR THE TYPE <br />#10-2coppertowy -9 copper to Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />SHOW <br />LOCATION PURPOSES. <br />2/0 or 4/0 SER Alu <br />200 amp <br />�^ <br />t� 2n <br />3" <br />150 amp <br />UNDERGROUND Disconnect <br />KA.II <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />rV I'j At G <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />�ENk nit �I `�q <br />V G <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />NT <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />{ PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />19 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />WP H.B. <br />GFI DISC. <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />VERIFY METER <br />LOCATION WITH <br />ELECTRICAL PLAN — ELEV-131 <br />SCALE: %4"=1'-0" <br />IuL-, <br />N <br />0 <br />N <br />1 <br />CN <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building <br />Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />F <br />O E <br />n <br />ED <br />a <br />0 <br />(cg M <br />N N 0) <br />00 <br />rk <br />_ <br />LJi <br />� �` w <br />W <br />3 w 0) <br />rnr a <br />Mv <br />LL w °- <br />CL <br />a <br />ca U_ LL <br />�Yn <br />a u 5 <br />Z <br />o� <br />o <br />W�6'O' <br />' <br />t.6Nm <br />F <br />a O <br />¢ <br />Z <br />LL IL <br />¢ a <br />Z <br />'n MZ <br />N OU <br />�yO <br />U�Cn <br />W <br />❑O❑ <br />Z N m <br />0 <br />Z <br />QN <br />Z O Q <br />J — <br />d � <br />— N <br />V O <br />® � <br />Vim• <br />O <br />W o <br />N C8 <br />aim <br />U c <br />u.t m <br />E <br />3 <br />I <br />I <br />z� <br />( <br />® <br />U <br />c (1) � <br />Q 0 <br />o <br />�Q <br />N <br />o <br />c <br />W <br />C13 <br />(h <br />z Z <br />O i <br />Z <br />L.L <br />E <br />w� <br />�� <br />Q <br />g <br />O <br />E <br />H <br />O <br />2® <br />oa <br />Do <br />O E <br />RQ <br />�o <br />�� <br />K <br />Z <br />N <br />L <br />rU <br />CY <br />z <br />U <br />'0 <br />oz <br />z <br />Z <br />tv <br />J <br />m <br />< <br />< w <br />g z <br />to <br />w <br />oa <br />go <br />W <br />U <br />LL <br />a j <br />a <br />�W <br />x,k <br />a� <br />Z <br />=3 <br />7F <br />J <br />O <br />cfl <br />w, <br />�m <br />a <br />Z <br />O <br />> U1 <br />n, <br />W <br />� <br />O <br />U <br />� <br />Q <br />C i <br />2 <br />O <br />o <br />m <br />� <br />W <br />O <br />M N <br />O LO <br />o (-4 <br />LO <br />r <br />M <br />M <br />o <br />C <br />E O <br />E <br />a3 <br />to <br />a <br />c0i <br />a o <br />c <br />JOB <br />NO: <br />20-8083 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />