My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39822 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39822 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 1:06:53 PM
Creation date
2/19/2025 10:22:59 AM
Metadata
Fields
Template:
Building Plans
Street #
39822
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
146
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with verttcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load �� • O <br />a e vertical load Safe horizontal load - <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />IW WA 0 WA <br />- • • • • <br />OV <br />• • �• 13 <br />8F44 1B/1T8F40 1B/1T 8RF400B/1T 8F321B/1T <br />FORM & GROUT SOLID <br />`- U <br />O /5 BAR CONT. <br />8F12-1 B/1T <br />0 <br />"V" LINTEL DETAIL <br />SCALE = N.T.S. <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />8 F 16- <br />B/ 1 T <br />a <br />tNOMINAL <br />tQUANTITY OF <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL - <br />HEIGHT <br />MATERIALS <br />. c p casflinteis = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 318" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Rebar per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />A <br />0 <br />#5RRECIQ'DAT ALTERNATE POWERS <br />M IN. (1) <br />L AR STEEL LINTEL <br />a <br />e <br />° .M.U. #5 REBAR AT TOP <br />♦° A MIN. (1) RECI'D ° d 1-1/2" CLEAR <br />e <br />° <br />GROUT <br />> 1�1 <br />*1� <br />, <br />n J 0 <br />¢ <br />H <br />Q !1 <br />4 <br />H <br />C.M.U. <br />5 REBAR AT <br />= T y w <br />- <br />a <br />• <br />BOTTOM OF <br />Z w <br />OF y- <br />LINTEL CAVITY <br />r U <br />`\ Q <br />Q <br />-BOTTOM <br />[r U O <br />• <br />REINFORCING <br />PROVIDED IN <br />LINTEL <br />¢� <br />¢ (9'o ^. <br />Z - in <br />¢ •' 0 5 0 <br />D /� D <br />Q <br />5 REBAR AT B( <br />J8"ACTUAL <br />MINAL WIDTH <br />0 ¢ a <br />AS INDICATED <br />(VARIES) <br />(0 <br />o o <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturers specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitfuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />i <br />5-10" LL <br />O O <br />4'-6" LL 4'-6" LL <br />O <br />6'-6" LL <br />(E) <br />MIN. <br />17'-4" LL <br />O <br />5'-10" LL <br />LINTEL PLAN - ELEV-Al <br />SCALE: 14"=1'-0" <br />• <br />c1- r/ G) <br />i <br />FLOC\ <br />A '••...•.••"�•, V <br />,��0 S 10 <br />f <br />To the best of the Engineers knowledge, information and belief, <br />the stru tural plans and specfications wkhin contained these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />g o N u- <br />N 6 c LL <br />Q 1; 2 S * LL W <br />O LL 0. YYn <br />� <br />LL LL a W 5 <br />Z. L to vq� O ion <br />0 S <br />k�r cp Gr O _J <br />m <br />CP <br />Z uo F, 0 _J <br />LL k� � N <br />ZN OU <br />W o00 <br />U `.? V <br />Z N <br />Z <br />Z <br />J <br />d <br />Z � <br />U <br />IL <br />� <br />t• V LLJ <br />- <br />OU g� <br />W N <br />� <br />C <br />w <br />N <br />oil <br />W <br />Z <br />�CZ) <br />r, <br />o <br />r. <br />o€z <br />Z• <br />o <br />F- ,6 <br />wz <br />x g <br />a <br />0 o <br />Z <br />0 E <br />i <br />yyU <br />S Z <br />�d o <br />.�_. <br />C: <br />- _ <br />�gw <br />�x <br />m f <br />F p <br />>z <br />Z�� <br />� J <br />pia <br />irk <br />g <br />N { <br />¢w <br />g <br />ZZ <br />io <br />W <br />a <br />A `� <br />U <br />KS <br />�� <br />�w <br />S� <br />�- <br />MJa <br />0_ <br />I <br />0- <br />03 <br />0 <br />0O <br />= <br />Lo <br />DC <br />L <br />d <br />c� <br />0 <br />LO <br />0)D <br />Q <br />( <br />Y > <br />CL <br />m C <br />'0 <br />E N <br />'It <br />r <br />2 <br />0).� <br />v N <br />t 4 <br />LO <br />r <br />T U-) C0,04 <br />o) <br />T <br />m <br />Z <br />i'7 <br />3 T iri <br />d <br />Z <br />E O �, <br />a <br />0 _J a o <br />_J <br />JOB <br />NO: 20-8084 <br />SCALE : AS NOTED <br />SHEET NO. <br />8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.