Laserfiche WebLink
V 2x BLOCKING HORIZONTALLY@ <br />2x #2 SPF STUDS INTERVALS NOT EXCEEDING <br />@16" O.C. W/ (2) 10'-0" (R302.11) <br />16d TOENAILS T & B <br />1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z <br />APPLICABLE. <br />2x P.T. PLATE 1/4" DIA. X 31/4" TAPCONS @ 24" O/C & i <br />@ 6" MAX FROM END OF 2 x PLATE <br />FOR UNDERLAYMENT (2) #5 CONT. ON 3" 6 x 6 W1.4 x W1.4 <br />REQUIREMENTS SEE R905.1.1 CHAIRS (TYP.) WWF OR FIBERMESH °' <br />PRE ENGINEERED WOOD <br />TRUSS @ 24" O.C. U.N.O. <br />HURRICANE ANCHOR @ EACH <br />I' <br />TRUSS (SEE UPLIFT SCHED.) W/ I , I ° ° • <br />12 METAL PL. UNDER EA. TRUSS I jLnIr <br />Z7.)TYVARIES MOISTURE BARRIER <br />I <br />SHINGLE ROOF 8 <br />INSU ION LE ROOF SHEATHING - SEE <br />SCHEDULE - [RSH] - ON TYPICAL INTERIOR BEARING <br />FRAMING SHEET FOR <br />SHEATHING AND FASTENERS WALL w/ OUT UPLIFT rG G <br />ELEV. VARIES SEE TYP. WALL SECTION SCALE: 3/4"=1'-0" S3 <br />5/8" OR 1/2" HIGH ALUMINUM DRIP <br />STRENGTH CEILING EDGE <br />BOARD PER CODE (OR 5/8" ALUMINUM FASCIA <br />GYP. TYPE "X" @ GARAGE <br />5/8"OR 1/2" HIGH STRENGTH TRUSS BOTTOM CHORD OR 2x4 #2 SPF 5/8"OR 1/2"HIGH STRENGTH TRUSS BOTTOM CHORD OR 2x4 #2 SPF <br />(U.N.O.) (OR %" GYP. TYPE "X" @ BLOCKING @ 12" O.C. w/ (2)12d TOE NAILS BLOCKING @ 12" O.C. w/ (2)12d TOE NAILS <br />GARAGE W/A HABITABLE ROOM <br />GARAGE W/A HABITABLE ROOM EACH END (WHEN PARALLEL) .) (OR %" GYP. TYPE @ EACH END (WHEN PARALLEL) <br />ABOVE) SEE UPLIFT SCHEDULE FOR UPLIFT GARAGE SEE UPLIFT SCHEDULE FOR UPLIFT <br />S.P.F. DOUBLE <br />CONNECTIONS. ABOVE) CONNECTIONS. <br />8"x8"xl6" NOMINAL BLOCK WITH TOP PLATE S.P.F. DOUBLE <br />3/8" MORTAR BETWEEN COURSES SIMPSON SP2 w/ TOP PLATE <br />(12)10d NAILS 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. SIMPSON SP2 w/ 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. <br />L1/2" CDX PLYWOOD OR 7/16" O.S.B. (12)10d NAILS U.N.O. <br />SHEATHING REQ'D. FOR ALL 2x BLOCKING HORIZONTALLY@ INTERVALS 5/8"° x 10" "J" BOLT @ 24" O.C. w/ 2x BLOCKING HORIZONTALLY@ INTERVALS <br />EXTERIOR OR SHEAR WALLS AS NOT EXCEEDING 10'-0" (R302.11) 2"°x3/16" PLATE WASHER (TYP.) NOT EXCEEDING 10'-0" (R302.11) <br />INDICATED ON THE PLAN. ATTACH (ALT: 1/2"x12" TITEN HD @ 24" <br />SHEATHING W/ 8d COMMON NAILS @ NSULATION PER CHART ON FLOOR PLAN O.C. OR 5/8"x10' WEDGE ANCHOR NSULATION PER CHART ON FLOOR PLAN <br />3/8" MORTAR BETWEEN 4" O.C. @ BOUNDARIES, 6" O.C. @ @ 24" O.C.) <br />SLAB & BLOCK EDGES, AND @ 12" O.C. @ FIELD "SIMILAR AT FOUNDATION ONLY" <br />_ <br />IMPSON SP1 w/ (10)10d NAILS IF NOTED, THIS REFERS TO THE SIMPSON SP1 w/ (10)10d NAILS <br />2"°x3/16" PLATE WASHER (TYP.) STEP, SIZE OF FOUNDATION AND <br />ELEV. 0'-0" OIL (ALT: 1/2"xl2" TITEN HD @ 24" 2x P.T. BOTTOM PLATE REINFORCEMENT AND WILL NOT 2x P.T. BOTTOM PLATE <br />A.F.F. T O.C. OR 5/8"x10' WEDGE ANCHOR x 6 W1.4 x W1.4 INCLUDE THE WALL / 6 x 6 W1.4 x W1.4 <br />0@ 24" O.C.) 211 WWF OR FIBERMESH ATTACHMENTS 2" WWF OR FIBERMESH <br />e <br />z �31/2" MIN. �31/2" MIN. <br />a ° ° ° ° ° e ELEV. 4-3 1/2" <br />e a ° e A.F.F. <br />2x4 CONT. e <br />o 1/2"(min.)- 4" _ ° , 9'' 1/2"(min.)- 4" <br />I° ° = a ° ° N rb 00 / <br />GARAGE DEPTH VARIES ° I° 31/2"(min.)- 4' — ° • 31/2"(min.) - 4" <br />e — — <br />e ° ° g ° <br />(2) #5 CONT. 13 <br />4" 11 8" (2) #5 CONT. 4" � g <br />GARAGE SLAB AT STEP rB U.N.O. MIN. TYPICAL BEARING WALL STEP <br />TYPICAL BEARING WALL STEP SHEARWALLrc� @ CC <br />SCALE: 3/4"=V-0" k,S3 "SHEAR WALL" SCALE: 3/4"=1'-0" S3 SCALE: 3/4"=V-0" S3 <br />cam' ` 0 <br />W/A HABITABLE ROOM 12" N.O. 2x SUB FASCIA 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING Qcs <br />ABOVE) W/DRYWALL EE SOFFIT NAILED W/ 8d COMMON NAILS @ 4" O/C <br />SCREWS @ 7" O.C. S <br />HEET 2x S.P.F. STUDS @ 16" O.C. BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. <br />CEILING & 8" O.C. WALLS 2x STUD SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. 2x STUDS @ 16" O/C N�o 5 <br />LOAD BEARING OR INSULATION PER FBC AND ENERGY cow 2x BLOCKING HORIZONTALLY <br />"x8"X16" KNOCK-0UT @ <br />INSULATION PER BLOCK 6" N CONT. EXTERIOR WALL 8" C.M.U. FORM SUBMITTED WITH PERMIT NOTE: INTERVALS NOT EXCEEDING <br />CHART ON FLOOR FILLED SOLID W/GROUT 1"x P.T. STUD 2x BLOCKING HORIZONTALLY@ APPLICATION 10'-0" (R302.11) <br />INTERVALS NOT EXCEEDING SEE SECTION C/S3 FOR <br />PLAN 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 <br />� #5 VERT. IN FILLED CELL 10'-0" (R302.11) ADDITIONAL INFORMATION <br />1x2 P.T. HORIZONTAL SEE CC/S3 OR N LAYERS W/ TOTAL THICKNESS 7/8" OVER 1/2" GYP. WB (MIN.) @ GARAGE <br />NAILER 8" C.M.U. TYPICAL G/S3 FOR ANCHORJMETAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL SIMPSON SP1 w/ (10) SIDE IF APPLICABLE. <br />5/8"x6" "J" BOLTS BOLT 5/8"° x 10" "J" BOLT @ 24" O/C W/ 2"°X 3/16" 10d NAILS <br />BOLT INFO. 3RD LAYER 1/8" THICK. K.O. BLOCK <br />STD. 90-HOOK (SEE DETAIL) TYPE "S" MORTAR (IF NO UP LIFT ON @ 24" O.C. VERT. OR PLATE WASHER TYPICAL 5/8"DfA. EXPANSION BOLT @24 " <br />WALL SEE GG/S3) 5/8" x 6" EPDXY BOLT OR SIMPSON SP1 w/ (10)10d NAILS @ EA. STUD 2x P.T. PLATE O.C. W/ 7" EMBEDMENT (MIN. SHEAR <br />MIN. 2500 PSI CONCRETE SLAB W/ <br />6 1/4"x31/4" TAPCONS 3500#, MIN. TENSION 2600#) <br />() 6 x 6 W1.4 x W1.4 WWF OR 2X PT PLATE 20" MIN. LAP [24" MIN. LAP] #5 REINFORCING SPACE ANCHOR <br />*SIMPSON SP1 SPACED EVENLY FIBERMESH BAR ¢ BOLTS 6" MAX FROM 6 x 6 W1.4 x W1.4 N c <br />ARCHITECTURAL w/ 00)10d NAILS = WEEP SCREED INSTALLED o END OF Z" x PLATE WWF OR FIBERMESH '- E <br />FINISH TYP. r 2x P.T. PLATE �. c� <br />c PER MFR INSTRUCTIONS <br />1x2 PT WD FURRING @ 24" O.C. ASSUMED FINISHED #3 OR #4 REINFORCING BAR 0 o ° <br />r t = a , o GRADE 40 MIN. Fy= 40ksi <br />1/2 GYPSUM WALLBOARD GRADE �„ - p z_ #3 & #4 LAP SPLICE <br />" T FINISH GRADE oo (GRADE 60 MIN. Fy= 60ksi] a ° ° c� <br />U.N.O. (1) #5 VERT. IN FILL MONO OR STEMWALL ° z -0 , • 25"MIN. LAP [30" MIN. LAP] g D r <br />CELLS (SEE FOOTING MONO SHOWN o — _ uj <br />° o °� _ 00 6 MIL VAPOR BARRIER P , ° <br />R 1 7/8° `U) e <br />FOUNDATION PLAN FOR CLARITY ° °� . " � . � T #5 REINFORCING BAR <br />FOR LOCATIONS) p p D ° P =1 1=I 1=I 1=1 11=1 1=I �„ z _ <br />1x4 P.T. BASE NAILER ° I i I —I i I —III —I 11=1 I I —III- <br />4"x4" INSPECTION D ° _ _ • T #5 LAP SPLICECONT.- <br />3 <br />2 #5 m <br />I—III=I II=III—III—III—II � ( ) <br />PORT AT EACH NOTE: g ' III=III—III—III—III—III- N , ° ' 36" MIN. LAP [36" MIN. LAP] ON 3" CHAIRS <br />1/4" BASEBOARD COMP. SOIL. (COMPACTED TO — 8" V-4" 8" <br />FOR BEARING WALL =III=1 � 1=1 � 1=1 � =1 � I= I T <br />FILLED CELL TYPICAL _ _ _ _ _ _ _ _ _ _ _ _ —I' 95%MODIFIED PROCTOR ASTM 10" �P•) <br />W/ UPLIFT ONLY <br />MIN. 2500 PSI CONC. SLAB _ _ _ _ _ — i— <br />co AT GARAGE CONTRACTOR � =1 � =1 � 1=1 1=1 1=1 11=1 I=1 I I=1 I=1 1 1= I =I I =I 11=I 1=1 � 1-1 I D1557) <br />MIN PSI MAY VARY PER -I 11-III—III=1 I =III=I 1=III=1 1=1 1=1 1=1 I 1—I I 1=1 I 1=I I P ' 4" 1��" #6 REINFORCING BAR #5 STD. 90 HOOK <br />TO CUT BLOCK OR POUR "—=111-III_=1 ; I I II I Ii I„III ; I 1=III-III= I i #6 LAP SPLICE <br />MUNICIPALITY. CURB DUE TO SLOPE TYPICAL INTERIOR BEARING <br />CONCRETE SLAB W/6X6 a NOTE:EXTEND W14XW14 FRAME WALL TO C.M.U. WALL CONNECTION D TYPICAL EXTERIOR FRAME WALL FOOTING E REBAR DETAILS rF WALL w/ UPLIFT <br />WWF OR <br />"FIBERMESH" <br />M a <br />•C <br />° ` <br />DECO FINISH 4" to 6" <br />BELOW GRADE <br />= Z <br />I <br />SCALE: 3/4"=V-0" <br />SEE TYP. WALL SECTION FOR ADDITIONAL S3 <br />SLAB INFORMATION. <br />6x6W1.4xW1.4 <br />° <br />31/2" WWF OR FIBERMESH <br />6 MIL VAPOR <br />> t <br />? <br />min.) 4" <br />BARRIER <br />D: p • 9 <br />N <br />" a a GRADE <br />COMP. SOIL. <br />r <br />°p • <br />(COMPACTED TO 95% <br />_ (1) #5 REBAR wl OPT. <br />MODIFIED PROCTOR <br />— SC�NCLOSURE <br />ASTM D1557) <br />R. <br />#5 REBAR CONT. <br />O N CHAIRS TYP. <br />1'-4" (1 STORY) <br />STD. 90 HOOK (SEE <br />4' I <br />MIN. <br />.O U <br />U.N.O. <br />4" l'-8" (2 STORY) <br />DETAIL) <br />TYPICAL WALL SECTION <br />A <br />TYPICAL THICKENED SLAB EDGEL <br />SCALE: 3/4 -1-0 <br />S3 <br />E.3/4"=1'-0" <br />S3 <br />OPT: DEPRESS SLAB 5 Y2" <br />DEEP AND 6" BEYOND <br />DOOR TO RECEIVE C=== BLOCK WALL BEYOND BLOCK WALL BEYOND <br />PAVERS / DRIVEWAY IEXPANSION JOINT I <br />^ <br />CONCRETE SLAB 14 13 <br />PAVERS O.H.D. RECESS z O.H.D. RECESS E <br />M � , <br />4" ao <br />SEE A/S3 OR J/S6 FOR REINF. INFO. 3" MIN. CLEARANCE <br />1'4" (1 STOR ) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) <br />1' " (2 STOR ) <br />GARAGE DOOR SLAB RECESS J.1 <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />N <br />C'7 <br />�.••; <br />eh • 4.' . r <br />A" <br />SEE A/S3 OR J/S6 <br />FOR REINF. INFO. I I I 3" MIN. CLEARANCE <br />1'4" (1 STORY) <br />V-8" (2 ST RY) <br />GARAGE DOOR SLAB RECESS J <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />SEE TYP. WALL SECTION FOR ADDITIONAL <br />SLAB INFORMATION. <br />SCALE: 3/4"=1'-0" S3 SCALE: N.T.S. S3 SCALE: 3/4"=l'-0" <br />P.T. 2x 1/2" GYP. BD. <br />HOLD GYP. BD. <br />1/2" FROM SLAB <br />:5 CONT. BEAD SEALM <br />-- <br />INTERIOR <br />°.`' -3 1/2" <br />... . <br />. v ' <br />CONCRETE NAILS W 1 1/2 <br />EMBEDMENT @ 12" O.C. <br />STAGGERED, FROM BOTTOM <br />PLATE TO CONCRETE <br />(MIN. SHEAR 180# MIN. <br />TENSION 120#) CONCRETE SLAB <br />a <br />°Q c <br />E : •.. <br />— <br />N <br />M 6 MIL VAPOR _ <br />BARRIER <br />S3 <br />VARIES6 <br />SEE PLAN <br />1 1/2" RECESS FOR x 6 W1.4 x W1.4 <br />FRAME -DOWN FALSE BEAM w/ (3) SEE ROOF PLAN <br />S.G.D. (U.N.O.)7 WWF OR FIBERMESH <br />10d NAILS TO TRUSS TOP CHORD FOR TRUSS <br />AT 24" O.C. MAX. _ = CONNECTION INFO <br />= <br />SEE PLAN FOR _ <br />&LAYOUT DESIGN <br />a <br />TOP OF BEAM <br />SEE ROOF PLAN <br />Qo <br />C ° a, a ° .a ° <br />(2) HTS20 FOR STRUCTURAL <br />:= <br />_ co `- <br />BEAM SIZE & <br />_ �' <br />1 a <br />CONNECTION INFO <br />Cl) ° 8 <br />I I <br />2x4 #2 SYP P.T. FRAMING w/ SEE A/S3/J/S6 <br />MIN 7/16" O.S.B. SHEATHING 8" <br />z ATTACHED PER NAILING FOR REINF. INFO. <br />W SCHEDULE OPTION #1 <br />a SEE TYP. WALL SECTION FOR ADDITIONAL <br />j w SEE PLAN FOR STRUCTURAL SLAB INFORMATION. <br />FOUND TION <br />w <br />COLUMN SIZE AND BASE <br />25 <br />W <br />CONNECTION INFO. <br />SLAB STEP & RECESS <br />S.G.D. <br />rM <br />co <br />SCALE: <br />S3 SCALE: 3/4"=1'-0" <br />2X STUDS @ 24" O.C. U.N.O. <br />2x4 P.T. BTM. PLATE <br />SEE DETAIL 16/D1 FOR <br />w/ 1/4"x3" TAPCONS <br />MASONRY WALL AND <br />GARAGE <br />COLUMN TO PORCH SILL <br />AT 8" O.C. <br />PAD FOOTING <br />ATTACHMENTS & 18/D1 <br />1/2" GYPSUM WALLBOARD U.N.O. <br />FOR COLUMN TO BEAM <br />TRIM PER PLAN <br />8" MASONRY WALL <br />-, <br />W/ DRYWALL SCREWS @ 8"O.C. <br />ATTACHMENTS <br />EXTEND FILL CELLS <br />_ <br />TO FOUNDATION PAD <br />INSULATION PER CHART <br />SQUARE CMU BLOCK BASE, <br />CONT. FOOTING STEEL <br />i/ <br />MAT REINFORCING. �' ' <br />ON FLOOR PLAN <br />SIZE VARIES PER PLAN <br />r> <br />CONT. BEAD SEALANT <br />w/ MIN. (2) #5 VERTICALS <br />00 <br />GRADE <br />a ° <br />FILLED SOLID (SEE PLAN FOR <br />6 x 6 W1.4 x W1.4 <br />SIZE AND REINFORCEMENT) <br />°. <br />1=III=III=IIII=I1 <br />WWF OR FIBERMESH , <br />a w W <br />_ <br />v <br />° <br />BRICK PAVERS or SLAB PER <br />p o �' _ <br />-III= <br />• <br />• °• <br />—_ - z_ <br />— <br />0'-0" FIN. FLR. A <br />COMMUNITY SPECS <br />" � -- <br />—I <br />— ° <br />—III—I � I—III-11 <br />— <br />_ <br />CO <br />— _-- <br />—I i ' 111 <br />_ <br />III=1 1=1 I 1=1 <br />I—i <br />= <br />III —I 1=1 11= FOOTING <br />IIl�illlliillil�� <br />111 <br />-III, -III=' BEYOND <br />- <br />,. <br />..... <br />PAD REINFORCEMENT-]3" <br />,II <br />MIN. CLEARANCE <br />•1 <br />• �• <br />� � <br />SEE <br />(SEE SCHEDULE) <br />4-. ' •• :1. coNc.anD INFO.. FOOTING WIDTH <br />• <br />s • SEE SCHEDULE <br />INTERIOR WALL SLAB STEP NON-BRG. rK TAPERED COLUMN FRAMING CD12 PATIO COLUMN FTG. DETAIL N <br />SCALE:3/4"=1'-0" S3 SCALE: 3l4"=1'-0" <br />SCALE: N.T.S. S3 <br />.�.� pR0 Wiy ra <br />S E •.� <br />U �r Opt <br />v <br />r�s���•�UFSSS10�r <br />e� <br />1 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W n <br />E <br />F �8�� <br />a <br />FA LL <br />,� W <br />dl' to � � 32 -1 w a <br />LLaY <br />Q �v <br />LL U. a'. S <br />O <br />z � ` F 1? 1 <br />N CO tr 0 <br />W °�' Q Q <br />Z u°pN, 4 Z y 0 <br />L a <br />O U <br />Z 0 �3co <br />W ❑❑❑ <br />CD <br />z <br />z � <br />Z n <br />v <br />W <br />•U <br />0 W s <br />Vt c N <br />M <br />W <br />LL <br />E <br />0 <br />w� <br />�� <br />a <br />� O <br />E <br />w? <br />oa <br />0 E <br />C ) <br />$o <br />wOo <br />�o <br />a <br />rc� <br />M <br />- <br />H <br />m� <br />'° <br />°z <br />Z F <br />co J <br />O <br />9m0 <br />F•" <br />i <br />ZZ <br />W <br />N <br />a <br />T <br />o <br />¢ <br />aZ <br />n <br />= <br />U <br />a <br />LL <br />�_ <br />r <br />O <br />ai <br />< <br />zla <br />3 <br />0 <br />`O <br />= <br />> Ln <br />rn <br />> <br />Ln <br />^ <br />Q <br />> <br />2 <br />O <br />AC`` <br />W to <br />o <br />T7 <br />LO <br />i Lo 04 <br />TT T <br />C <br />T <br />E <br />V! <br />M <br />o <br />Z <br />= <br />E O m <br />E ;3 :3 <br />0 <br />M <br />c <br />a <br />_j a o <br />JOB <br />NO: 20-8084 <br />SCALE : AS NOTED <br />SHEET NO. <br />S3 <br />(MONO) <br />