My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39831 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39831 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 2:06:00 PM
Creation date
2/19/2025 10:23:13 AM
Metadata
Fields
Template:
Building Plans
Street #
39831
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
1642
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />uNt 0r <br />STRUCTURE ABOVE <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-0" <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /411 = 1'-0" <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR TH <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />NFPA 72 2016 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS FRO GARAGE MUST BE SERVED <br />BY SEPARATE BRANCH CIRCUIT THAT DOES NOT SUPPLY <br />OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR, <br />NOTES: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR <br />SIDE -HINGE DOORS SHALL BE TESTED AND LABELED <br />WITH A PERMANENT LABEL PROVIDING TRACEABILITY TO <br />THE MANUFACTURER AND PRODUCT. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />#12 copper to 20 amp ckts <br />01 <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steal <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />Za <br />SWITCH <br />DOOR <br />JAMB <br />0 <br />4 1/2" <br />TRIM <br />BASE <br />TRIM <br />DUPLEX _ <br />OUTLET 9 <br />cq <br />0 <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />ROUGH FRAMING <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />0- WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />8wSTRUCTURED WIRE OUTLET <br />6— SWITCH AT 36" <br />9 3 WAY SWITCH AT 36" <br />r 4 WAY SWITCH AT 36" <br />-o PUSH BUTTON FOR GARAGE DOOR OPENER <br />—❑ DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />A} CLG MNT LT FIXTURE <br />TCLG MNT PREWIRE - FIXTURE BY OWNER <br />C SURFACE MNT FIXTURE <br />{- WALL MNT FIXTURE <br />NOTE: <br />C TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />C 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />C RECESS CAN OR LED OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />moo) 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />{} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cM SMOKE DETECTOR <br />O SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />97�24:�_@ 24" VANITY LIGHTING <br />36 � 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />® EXHAUST FAN <br />p� DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />>� MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR (W/ SIZE) <br />A/C REGISTER <br />C THERMOSTAT <br />® SECURITY PAD <br />In ELEC METER <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION <br />PURPOSES. <br />N LO ; E <br />-O 11 U <br />V) c�iN <br />0 co <br />y <br />-0 <br />m <br />o <br />Z) 0 2 a <br />o p Q <br />U o^ N Q <br />iD ,q <br />w QN <br />� FM � <br />C) iD 0 <br />Lu LLI U) W 0 <br />W F W J W 0 <br />LU uj <br />0vuW��C 2=o�Yz�Z oz <br />LQ0O�D—JUX u UOO <br />-_j0~Q D0zLLwz2 ¢a0 0W00MzLuV5w 2 0- W�wwW°wLow0 z ~0zLL a0Q <br />= o0 Q <br />w <br />J <br />O <br />O <br />N <br />z <br />w <br />O <br />O <br />Q J Lr <br />U LL <br />Q fu Q In >- O <br />z U F- <br />W <br />J O <br />l0 <br />d' <br />CO W O O O O <br />O O O O O O O <br />N N N N N N N <br />O O O O N A <br />N O <br />4 r O O O O N <br />0 0 0 0 0 <br />O <br />O O O O O O <br />N cyi 4 6 6 ti <br />W <br />Q <br />z <br />z <br />Z <br />Q <br />00 <br />T-i <br />LAST PLOT DATE <br />Feb. 9, 21 <br />Z Z <br />zo <br />a w u7 <br />C-) <br />�Q <br />M 0 Z <br />H=Z <br />Z 3: J <br />Z 2W <br />LL <br />aw <br />Z Z <br />=QO <br />1 ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />B <br />Q <br />z <br />z <br />W <br />J <br />I <br />O <br />O <br />U <br />
The URL can be used to link to this page
Your browser does not support the video tag.