Laserfiche WebLink
12 <br />5L,---'�: <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />INININININININI <br />14'-0" RIDGE VENT <br />12 <br />5� <br />N <br />Ma <br />12 <br />�5 <br />�) ------- ---------------------HEEL <br />12 <br />5� <br />F4 <br />— T.O.M. <br />----------------------- <br />HDR HGT. <br />O <br />TEXTURED <br />CEMENTICIOUS o� <br />FINISH ON C.M.U. co <br />(TYP. ) <br />1 <br />— F.FL. <br />FRONT ELEVATION - Al <br />12 <br />SCALE: 1 /4"=V-0" <br />15'-0" RIDGE VENT <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />---------- - - - T.O.M. <br />---------------- --HDR HGT. <br />------ -- —--0'— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -- — _ <br />10 <br />3'-0" <br />TEXTURED TEXTURED - <br />CEMENTICIOUS CEMENTICIOUS co <br />FINISH ON C.M.U. FINISH ON C.M.U. -p <br />(TYP.) (TYP.) <br />------F.FL. <br />LEFT ELEVATION - Al <br />N <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />r <br />r <br />OWN <br />\ <br />i <br />N <br />P <br />s � <br />v ; '�O <br />q. <br />� r/'ftlillltlll��1�! <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />g g <br />Q <br />c N J <br />Lo <br />.N.. Go C �p LL LL <br />0) <br />(01 ".0- 4. - �J a- <br />J y <br />LLLL W a <br />V <br />0 <br />J _ 0 <br />Z <br />�_°�' oI <br />W <br />�i <br />rp �C'y rp m O J <br />Z <br />co a <br />N Mz tYN0 <br />Z <br />ODUMai <br />W <br />❑ ❑ ❑ <br />(DR <br />z N <br />Z <br />z <br />J <br />a <br />z <br />N <br />UJ <br />O <br />N <br />c d <br />r— <br />U <br />c <br />Q 0 <br />• <br />N � <br />Cl) <br />N g <br />zos> <br />W <br />Z <br />J <br />E <br />io <br />ag <br />E o v <br />O ro <br />�1 <br />�o <br />oa <br />D° <br />Z <br />N <br />CN <br />to <br />W� <br />8 <br />m� <br />Z��g& <br />J <br />(� <br />lab <br />�Z <br />fA <br />5z <br />a <br />W <br />2Z <br />� <br />w <br />CIF <br />x <br />VMill!O <br />ilia <br />3 <br />�O <br />0 <br />= <br />m <br />C9 <br />L <br />1` <br />co <br />U <br />� <br />_ <br />Q <br />U <br />(D <br />o <br />r <br />O <br />C^ m <br />o <br />CD <br />W <br />E <br />L <br />IWIt <br />T <br />CO <br />� <br />N <br />Lo <br />T <br />o <br />E <br />r <br />cM <br />Ni r <br />d <br />Z <br />Z <br />E O <br />E <br />2 <br />w <br />'� <br />c <br />a. <br />U _J <br />Q p <br />_J <br />JOB <br />NO: <br />21-1069 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />