My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39856 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39856 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 3:39:22 PM
Creation date
2/19/2025 10:24:14 AM
Metadata
Fields
Template:
Building Plans
Street #
39856
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
1639
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />1 P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />T 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />MAIN <br />0 <br />200 amp <br />150 amp <br />---*#14 copperto lights & outlets <br />211 V <br />—♦ #12 copper to 20 amp ckts <br />—♦#10-2 copper to WH <br />I <br />— #10-3 copper to Dryer <br />/ LAB I SH�R <br />or 4/0 SER AID I V <br />UNDERGROUND Disconnect <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />`-AV 3 kl If <br />I w gUtiEN � <br />2 �0 V INk <br />NT <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />ENTRY <br />VERIFY METER LOCATION <br />WITH BUILDER <br />ELECTRICAL PLAN - ELEV-131 <br />SCALE: I4"=1'-0" <br />r <br />0 <br />2! <br />r` <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building <br />Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />v E <br />o m $ <br />m opo <br />ac <br />�8 <br />® <br />,r"am) <br />fO <br />*hit - <br />W <br />cn r -0 <br />No <br />a <br />- LLI _ <br />a — <br />Ile <br />B <br />0)MV <br />LL u_ <br />� rnI W <br />a L <br />Z <br />13 <br />J <br />0 o <br />�o <br />19 <br />rT� <br />a <br />W <br />Z <br />Ln�1 <br />co Ci <br />a <br />MZ <br />U <br />WLn0 <br />V <br />ZcumLO <br />W <br />��❑ <br />v M <br />Z N (h <br />0 0 <br />a <br />Ln <br />M <br />2 9 <br />O <br />Lu <br />Q <br />U <br />0 <br />g <br />o <br />�Nu) <br />Lu <br />o:.... <br />all <br />1— E <br />zl <br />< o <br />L dD Y <br />4 <br />14 <br />o <br />w <br />M <br />M <br />¢ <br />o <br />_ <br />Q <br />ILL. <br />c6 E <br />zo <br />�O <br />>N <br />za <br />4 <br />Q 0 <br />E <br />� <br />Z® <br />Iu <br />KO <br />uO <br />CIL <br />� <br />as <br /><o <br />�� <br />ww <br />L <br />ru <br />(n <br /><o <br />ZZ <br />O. <br />U <br />mo <br />Ol <br />Z <br />m O <br />Q W <br />Z <br />oa <br />o <br />g <br />L <br />>° <br />o <br />w< <br />aF <br />za <br />o3 <br />O <br />N <br />L^ <br />/ <br />LL <br />ui <br />W <br />� <br />O <br />.>O <br />N <br /><t <br />C. Y <br />O <br />U <br />0 <br />''2R <br />V <br />Al m <br />W <br />� <br />E <br />N <br />L <br />LO <br />r <br />d' <br />0000 <br />r <br />LO <br />.. <br />ui <br />2�, <br />N <br />M <br />a <br />z <br />E 0 <br />to <br />a <br />E <br />v <br />a3 <br />c <br />_j <br />¢ o <br />JOB <br />NO: <br />21-1078 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />