My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39870 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39870 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:07:31 PM
Creation date
2/19/2025 10:24:30 AM
Metadata
Fields
Template:
Building Plans
Street #
39870
Location
Harmon Grove Ct
Contractor
Lennar Homes
Building Plans - Permit #
1638
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />II � <br />#14 copper to lights & outlets <br />150 AMP/ 00 #12 copper to 20 amp ckh; / <br />Zoo AMP 01 #10-2 copper to WH I I <br />#10-3 copper to Dryer <br />`/, <br />METER <br />MAIN <br />O/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND Disconnect <br />POWER CO. FEED_: <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING 44 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f� <br />SPECIAL PURPOSE OUTLET <br />0 <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />F O <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e� <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />1-0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />19 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />VERIFY METER LOCATION <br />WITH BUILDER <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: Y4"=1'-0" <br />N <br />_o <br />CO <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />Q <br />E <br />O 8 <br />N <br />LQ <br />O N <br />O m*? <br />J <br />J LL <br />0 <br />00 <br />5 co ai <br />* . W <br />N <br />to rLu <br />N C) <br />u- 0 Y <br />Q <br />MLLLL <br />Wau,y <br />Z <br />13 <br />L <br />C) S <br />f6 <br />z M N <br />on O J <br />in <br />Z <br />N M <br />a <br />X Ln <br />OZ <br />o<ILUZ <br />vvi <br />W <br />❑ ❑ ❑ <br />CD M <br />z <br />N <br />z <br />Z o <br />a <br />J <br />N <br />M <br />(on <br />z o <br />� <br />fQ u w <br />U <br />0 <br />w <br />N <br />c M <br />Ln � <br />in <br />03 <br />(� <br />� <br />r— <br />U <br />w o <br />� J E <br />I <br />U o ai <br />c u) w <br />ul o <br />• <br />�0 <br />N <br />o <br />w <br />ce�Z <br />M <br />o� L <br />Z <br />U_ <br />U_ <br />ca E <br />d <br />E <br />z <br />zo <br />Oo <br />�� <br />Q0 <br />Z® <br />o <br />x� <br />�w <br />a� <br />_o <br />o <br />Z <br />N <br />O J <br /><'z <br />o <br />o <br />°do <br />Wz <br />r� <br />mo <br />NUY <br />C <br />U <br />wo <br />O ¢ <br />Y2 <br />Z <br />U)<. <br />�Z <br />o� <br />go <br />Q <br />a <br />w W <br />W <br />w <br />�o <br />o <br />w� <br />�O <br />a r_ <br />Oo� <br />z¢ <br />0 <br />>L6 <br />� <br />L <br />Al <br />W <br />� <br />C9 <br />ill <br />U <br />0') <br />II.�LL <br />a) <br />T <br />C V <br />> <br />2 <br />0 <br />I1 <br />0 <br />0 <br />(0 <br />m <br />O <br />� <br />•� <br />= N <br />T <br />0) <br />LO <br />T <br />i 0-) <br />00 <br />o) <br />O r— <br />ai <br />E <br />M <br />o <br />z <br />E 0 <br />to <br />f0 <br />a <br />Eto <br />U _j <br />Q p <br />c <br />JOB <br />NO: <br />21-1072 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.