Laserfiche WebLink
Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood nels or 2 x — <br />Pa <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-118" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap —i <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING Ya" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />Non -stacking walls <br />over squash=20 blocks and <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or-20 sinker <br />lateral load. nail each side <br />10'-0" at bearing. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-011 <br />< CD <br />- <br />STU&OUT FOR O 1'-011 o o i1) <br />GAS METER 0 <br />0 0 <br />CV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />V-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />16 4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />1✓ Provide adequate bearing <br />for each lapped joist. <br />10dnails SECTION @ INT. BRIG. WALL <br />N.T.S. <br />"" """" `"'­ ' MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges it <br />FILL CELL STD. 90° HOOK BOND BEAM <br />w <br />STD. 90° CONT. #5 <br />BAR >I HOOK BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />1 <br /># OF 2nd FLOOR <br />Solid block all posts from <br />above to bearing below. <br />STUDS <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. Small 2" min. <br />2" } gap <br />max � 4 max. <br />Clinch nails <br />when <br />possible <br />Tight fit — �_ �1 <br />2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series Depth End 1 <br />BC15000s 11-7/8"'' <br />_ 14" <br />9-1/2" <br />6000SO 11-7/8" <br />rClB6500sPP 14" <br />16" <br />-Intermediate_ <br />2-8d 2-8d <br />2-8d . _ - 3-8d <br />1 2-8d 5-8d <br />2-8d 2-8d <br />2-8d <br />5-8d <br />2-8d <br />6-8d <br />-- <br />BC160sP <br />11-7/8"' <br />2-8d <br />3-8d <br />14"- <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />11-7/81' �3-16d', <br />BCI90s® 14" 5-16d <br />16" j 6-16d <br />3-16d <br />5-16d <br />6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />611 A 1Yz" ROUND HOLE MAY 6" 6 <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN <br />DO NOT CUT HOLES <br />LARGER THAN 1Yz" <br />ROUND IN <br />CANTILEVERS. <br />8 <br />T--0" <br />1'-1" <br />1'2' <br />1' 2" <br />V-3" <br />1'-3" <br />1'-7' <br />V-11" <br />2 <br />2-g' <br />32' <br />3 T" <br />- ---- Arry 16' joist --- 12 <br />T-0" <br />1'-1" <br />1'2' <br />1' 2" <br />1-3" <br />T-9" <br />2'-4' <br />2'-11" <br />3' T' <br />4'2' <br />4'2' <br />6-4' <br />Spars Qt)_ 16 <br />-- -- -- -- <br />1'4Y' <br />1' i" <br />1'2' <br />V--2" <br />V-7" <br />2'-6' <br />3'-7' <br />3'-10" <br />4'2' <br />S' T' <br />6-4' <br />T 2' <br />2ii <br />1'-0" <br />1'-1" <br />1'2' <br />1'-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5-11" <br />6-11" 7'-11" <br />8'-11.. <br />---- - — — -- -- -- - -- 24 <br />T- ' <br />1'4' <br />T2' <br />1-W <br />2-5" <br />3' T" <br />4-9' <br />5'-10" <br />T '' <br />8'-4 <br />9'-6 <br />10'-9' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />SIMPSC <br />w/(22)- <br />NAILS 1 <br />5/8"9 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install tight to top flange. <br />Joist hanger <br />Filler block. <br />� Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />i <br />I <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />_ requirements <br />-0.6 X Joist <br />p r o depth I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM—/ • ' •' <br />SEE PLAN FOR—"°• • . • • • <br />FOUNDATION INFO ` a ' °' <br />STEM FOUNDATION <br />F— GRADE REINF. SEE PLAN <br />NU 1,1nN�c 4 rvtl <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />- LOCATION OF <br />° SECOND H10A <br />SIMPSON H10A ° ° °' (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />I�I�11R. <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @PIPEIF <br />PENETPLUMBING LINE <br />RATION <br />q ° d <br />o d <br />\A A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />°a <br />o <br />a d <br />° n <br />SEE FND. PLN. <br />SIZE & REINF. <br />0 <br />N <br />o <br />`�`�,�11111lllJJJ <br />`E WKOj� S . <br />i <br />� . <br />` (J IV50 '• * <br />r CO <br />*• <br />of Lux <br />o�,���• n P��0 <br />IN'— `, <br />i1lOi i'. <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W LO <br />E <br />O $ N <br />6 cO <br />V a <br />Q 7�0 to #. LL W <br />LoQ <br />M fn-1r;� <br />a LL u, a <br />-.6 si ! a YY <br />jLLu aNL�5 <br />0o <br />I% jN;p m O _J <br />a <br />T" LO CLoO <br />NZ LL <br />N <br />< 0 a <br />O U U _J to <br />W ❑ ❑ ❑ <br />z W <br />z 8 <br />z <br />`4 <br />Q <br />(n <br />to z0 <br />8 <br />U�- <br />� <br />0 LU <br />N c <br />to � <br />I <br />U � � <br />• <br />Q - <br />N W <br />4111111 <br />O <br />w <br />z <br />M <br />o <br />Z® <br />o <br />I— ro <br />wos <br />xo <br />a��rU�o� <br />oa <br />,o <br />D <br />O <br />N <br />wo <br />aprcwmZ�g <br />1 Z <br />ryZ <br />�Fr <br />C: <br />J <br />_°Z <br />N <br />Q <br />oEF <br />a <br />rn w <br />W <br />y��y <br />O <br />z <br />W 2 <br />wo <br />a O <br />tD <br />40 <br />W <br />za <br />f <br />�3 <br />>� <br />J <br />m <br />m <br />0 <br />IL � <br />' U <br />> <br />O <br />0 <br />r1 <br />0 0 <br />(0 <br />C co co <br />� <br />... <br />E N <br />d. <br />r <br />co o <br />Lo <br />2 04 <br />r <br />L0 <br />r <br />° r <br />= N 04 <br />LO <br />r <br />W <br />Ili M <br />N <br />o <br />Z <br />Z <br />N <br />E m <br />co <br />o- <br />E v a3 <br />U � ¢ p <br />c <br />JOB <br />NO : 21-2033 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />