Laserfiche WebLink
nn merswr"rlflln' 1• 11.... FnFIWr g"IFl : YA" r 1 1 1 II 1 1 <br />12 <br />5� <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />------ <br />1" x 9" SMOOTH <br />--- <br />2 <br />-------------------------------- <br />I <br />t/BAND <br />❑ ❑ ■ ■ ■ ■ FA <br />HEAD <br />F711 El D FE11 D M D Lil I <br />I <br />171 M 71::11:1 El El 1:10� <br />-------- <br />--- <br />FE7 <br />I FE 7 <br />1II---11- <br />F_ 7_1 <br />E_�_l--- <br />--- <br />--- <br />12 <br />5� <br />T-0" <br />4' RIDGE VENT <br />12 <br />�5 <br />12 HEEL <br />N F4 T.O.M. <br />-----7 <br />— <br />-------HDRHGT. <br />----- -------- <br />I 5 <br />I <br />I <br />I TEXTURED <br />a 1 CEMENTITIOUS FINISH b <br />ON C.M.U. (TYP.) - ao <br />I CO <br />2" x 4" SMOOTH <br />TEXTURED <br />SILL / BAND <br />I <br />-----------------------------------F.FL. <br />FRONT ELEVATION — B1 <br />SCALE: 1 /4"= V-0" <br />18' RIDGE VENT <br />to <br />w <br />rn <br />w <br />PRE -ENGINEER TRUSS <br />12 <br />5 <br />w <br />FI <br />. FLR. <br />REFER TO FRAMING PLAN <br />FOR BEAM SIZE <br />2"x4" TYP. <br />5/8" TEXTURED OVER MTL. <br />LATH & 7/16" OSB SHEATHING <br />& FRAMING AS REQ. <br />REFER TO FLOOR <br />PLAN FOR POST SIZE <br />�2x FRAMING AS REQ. <br />POST TO CMU <br />CONNECTOR - REFER <br />TO FLOOR PLAN <br />(1) 2"X4" TYP. <br />\\\--(2) 2"X6" TYP. <br />SEE FOUNDATION PLANS <br />— — — — — — FOR FOOTER SIZE <br />COLUMN DETAIL <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />--------- T.O.M. <br />3'-0" TEXTURED <br />TEXTURED CEMENTITIOUS q <br />CEMENTITIOUS eo FIN. ON C.M.U. 80 <br />FINISH ON C.M.U. io (TYP.) <br />(TYP.) <br />2" x 4" SMOOTH <br />TEXTURED <br />------ SILL/BAND <br />LEFT ELEVATION — B1 <br />SCALE: 1/4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved fleshings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />0 <br />GV <br />is,� <br />co <br />LE Wks o <br />C13:•• N0 FE78750 <br />'•, <br />.. <br />r <br />it <br />AT ' 4•.` <br />`j8/}0NPA\-;' %% <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building <br />Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W n <br />E „ <br />a oo M8 �roppvk <br />t% N C' C <br />J LL <br />a <br />NG in�� <br />r- <br />Qm"0 <br />�,-, <br />- w <br />'L a Y <br />iE0 <br />Z rM8 <br />0� <br />:E CN <br />W��°'°' <br />a' 0 <br />Z N M Z <br />LL IL <br />a <br />a' N 0 <br />0V <br />Z <br />U� (n <br />W <br />v co eO <br />Z N <br />z � <br />Z:C7 <br />V <br />J — <br />tl � <br />E3 <br />N <br />th <br />N z <br />� � o <br />LL <br />4-1 <br />f�3 w <br />12 <br />U � <br />0 W s <br />N C N <br />w � <br />4t <br />L <br />¢ 0 <br />0 <br />S <br />w <br />Cl) <br />o <br />Z <br />� <br />L` <br />n E <br />�0 <br />?® <br />N <br />fo <br />a� <br />L)p <br />oZ2 <br />Z~ <br />O <br />N <br />i <br />�p <br />p <br />�¢o <br />aZ <br />w <br />2 <br />�_ <br />.9 <br />U <br />ro0 <br />gZ <br />Z <br />N J <br />I <br />y0 <br />" <br />F <br />}Z <br />2. <br />ar?'i 3 <br />d <br />H <br />ZZ <br />go <br />a <br />'Z <br />W <br />U � <br />w� <br />�y <br />O' <br />MillCDwa <br />I toCDi <br />is <br />°3 <br />T .0.1. <br />J <br />(0/O/� <br />C� <br />L � <br />CN <br />U <br />LO <br />Q <br />, <br />O <br />O <br />m <br />� <br />o <br />r <br />� m o <br />O <br />LO <br />LO <br />�T <br />T N N <br />LO <br />T <br />T <br />E <br />0000 <br />M <br />N <br />0 <br />M <br />Z <br />6i <br />E O <br />ca <br />EL <br />U � Q 0 <br />� <br />JOB <br />NO: 21-2033 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.1 <br />