Laserfiche WebLink
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed L/180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11, The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load / . O <br />Safe vertical load Safe horizontal load \- <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />i <br />8F44 1 B/1 T 8F40 1 B/1 T 8RF40 OB/1T 8F32 1 B/1T <br />FORM & GROUT SOLID <br />::. , <br />:a.7.,_ <br />CV Q <br />�0 <br />O #5 BAR CONT. <br />8F12-1 B/1 T <br />O <br />"V" LINTEL DETAIL <br />SCALE = N.T.S. <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />w <br />8F <br />1 <br />16 B/ T <br />¢ z <br />o <br />,g z <br />tNOMINAL.QUANTITY OF <br />#5 REBAR AT <br />WIDTH <br />TOP <br />NOMINA <br />HEIGHT <br />MATERIALS <br />1. cc precast lintels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#5 REBAR AT REQ'D ALTERNATE POWERS <br />M IN. (1) <br />CLEAR STEEL LINTEL <br />e O <br />e <br />d M.U. #5 REBAR AT TOP <br />e ° e MIN. (1) REQ'Df ° Q 1-1/2" CLEAR <br />a t1�L � l�_"� :Z <br />a <br />_ <br />e <br />G <br />GROUT <br />D <br />e <br />p o <br />_J <br />L�n9o: <br />4 <br />c <br />e <br />5 REBAR AT <br />= w rn , j <br />FZ <br />4 <br />0 <br />BOTTOM OF <br />F' rn Z W <br />0' � <br />o <br />LINTEL CAVITY <br />o V W <br />O <br />\ \ <br />0 <br />-BOTTOM <br />REINFORCING <br />PROVIDED IN <br />LINTEL <br />o a L3 <br />¢ ¢ C7 <br />Z Ci W u, <br />CWi 00'P <br />Co� <br />D D <br />Q p Q <br />ASRND CA <br />7-5/8"ACTUAL <br />NOMINAL WIDTH <br />(VARIES) <br />y m rL 'n <br />p ^ p <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN, <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION a@ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />O O <br />4'-6" LL 4'-6" LL <br />O <br />5-10" LL <br />LINTEL PLAN - ELEV-Al <br />SCALE: %4"=V-0" <br />N <br />0 <br />N <br />�Ekh/KO <br />^tisi�P <br />NS <br />• ,S•'L(,� <br />t 1J •� pE7$750 <br />•;,� <br />0 <br />01 .yZ. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal'.. <br />ao <br />ao <br />E r. <br />co r` at <br />N <br />I' <br />O N <br />0 <br />_ 0.0 N ii LL W <br />Nmo� LL <br />d Y <br />3 uu_ a <br />Z <br />lo] <br />mOco� Z <br />0P <br />0:o <br />sco <br />m N co O-1 <br />W <br />m <br />�rnrnaaa <br />Z <br />co 0 a <br />MZ 0 rn 0 <br />Z <br />N <br />OLL 0 U � N <br />W <br />oo❑ <br />z N o <br />z <br />Q <br />ri- ,;, <br />V) ^1 <br />- N <br />z Z <br />W <br />0 0 <br />u <br />4-1 <br />� <br />Ou� <br />�M <br />o <br />N <br />m <br />cn <br />we <br />M <br />wigw <br />U <br />E <br />_ c � <br />U) <br />® <br />® <br />Q <br />O <br />w <br />COM <br />M <br />¢ <br />zo <br />z <br />E <br />ZD <br />>N <br />0 <br />E U <br />t6 <br />O0 <br />a <br />Z® <br />w <br />UO <br />MUo <br />x <br />no <br />ZN <br />O E <br />N <br />a o <br />aO <br />¢o <br />K� <br />az <br />X� <br />L <br />co <br />Vi C <br />z <br />o <br />0 � <br />J <br />y n <br />c " <br />Q W <br />Z z <br />in <br />CL <br />o< <br />LL <br />go <br />a <br />�w <br />w <br />¢o <br />Nw <br />r- <br />r3 <br />o <br />z <br />wa <br />� F <br />'° <br />O <br />V <br />oW< <br />z¢ <br />a <br />O~ <br />03 <br />O <br />= <br />�L <br />J <br />O <br />m <br />C� <br />0 <br />L <br />� <br />0 <br />0 <br />r <br />•� <br />'� <br />> <br />o <br />O <br />0 <br />O <br />°° <br />o <br />� <br />= 04 <br />T <br />O <br />00 <br />T <br />r <br />CID <br />CM N <br />CU <br />z <br />Z <br />E O <br />V) <br />ra <br />a <br />U _J <br />Q p <br />_J <br />JOB <br />NO: <br />21-2024 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />