Laserfiche WebLink
� nI III ,.I, I I , il. .. ..II ,.. i. t•'!f:' ,L,.91 I ' <br />SIMPSON HGAM11 <br />W/ <br />(4)1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & (I <br />1/4"X2 3/4" <br />TITEN TO CMU <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING AND <br />FASTENERS. (MIN. FIRST 4 BAYS) <br />SEE STRUCTURAL NOTES AND NAILING TOENAIL w/ <br />SCHEDULE FOR SHEATHING DETAIL-7 (2)16d NAILS <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />MAX. 9" AND FASTENERS. (MIN. FIRST 4 BAYS) <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 BACKNAIL w/ (2)16d NAILS —� <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />MAX. 9" SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />UNSUPPORTED, AND FASTENERS. (MIN. FIRST 4 BAYS) <br />IF >9" SEE 10/S5 <br />BACKNAIL w/ (2) 16d NAILS <br />SEE STRUCTURAL NOTES AND NAILING <br />SCHEDULE FOR SHEATHING DETAIL �\\ <br />45"± <br />/ <br />45' ± <br />SEE STRUCTURAL <br />NOTES AND NAILING <br />2x4 CRO BRACE <br />SCHEDULE FOR <br />APPROX. 8" FROM <br />SHEATHING DETAIL 2x4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />RIDGE FASTENED AT <br />@ 8'4' 0/C. <br />EXTEND AT LEAST 90% OF <br />, <br />EACH JOINT W/ (3) 10d <br />"L" BRACE TO EXTEND <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />& (2)10d TOE NAILS @ <br />AT LEAST 90% OF WEB <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />2x8 P.T. <br />GABLE TRUSS <br />EACH JOINT w/ (3)10d & <br />FROM LEDGER TO <br />SILL <br />1/2" CDX PLYWOOD OR <br />(2)10d TOE NAILS @ EA. <br />BLOCKING <br />7/16" OSB SHEATHING <br />END <br />ATTACHED W/ 10d <br />GYPSUM WALL BOARD <br />]i <br />TRUSS <br />NAILS @ 6" O.C. EDGES <br />.GABLE <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />CDX PLYWOOD OR 7/16" <br />AND 12" O.C. FIELD <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />OSB SHEATHING ATTACHED <br />OS <br />10dX3" @ 3" O/C <br />CORD ATTACHED W/ (2) 16d TOENAILS <br />w/ 10d NAILS @ 6" O.C. <br />THROUGH CHORD <br />2x4 LEDGER (MATCH BOTTOM CHORD7 <br />EDGES AND 12" O.C. FIELD <br />INTO 2"x6" P T PLATE <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />AND FASTENERS. (MIN. FIRST 4 BAYS) <br />MAX. 9" <br />UNSUPPORTED, BACKNAIL w/ (2)16d NAILS <br />IF >9" SEE 10/S5 SEE STRUCTURAL NOTES AND <br />fa NAILING SCHEDULE FOR SHEATHING <br />L DOUBLE TOP PLATE <br />2"x4" CROSS BRACE <br />2x4 CROSS BRACE APPROX. 8" <br />APPROX. 8" FROM <br />FROM RIDGE FASTENED AT <br />RIDGE FASTENED AT <br />EACH JOINT w/ (3)10d & (2) 10d <br />EACH JOINT w/ (3) <br />TOE NAILS @ EA. END <br />10d & (2)10d TOE <br />NAILS @ EA. END <br />2x FRAME WALL (SEE WALL <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA, <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />BOTTOM ATTACHED <br />• <br />(2)16d NAILS <br />W/ (2) 16d TOENAILS <br />2x4 "T" ON TOP OF PANEL BLOCKING, 2"x6" P.T. S{LL NOTCH "L" BRACE HERE 2x4 PANEL BLOCKING @ 48" O.C. FOR 2x BLOCKING <br />WEEP SCREED THE FIRST (4) ROWS OF TRUSSES <br />FASTEN WITH 10dx3" @ 4" O/C SPACED 1/2" x 8" "J" BOLT @ 48" 0 C 2x4 "T" ON TOP OF PANEL <br />(2)16d <br />NAILS <br />@ 48" O.C. INSTALLED PER MANUF. WEEP SCREED FROM EA. END TYP. TOP & BOTTOM BLOCKING, FASTEN WITH SIMPSON HGAIOKT w/ (4)1/4"x1 1/2" SDS SCREWS TO —� <br />MOISTURE BARRIER SIMPSON META12 w/ (7)10dx1 1/2" NAILS AT 6'-0" INSTALLED PER MANUF. ATTACHED w/ (2)16d TOENAILS 10dx3" @ 4" 0/C TRUSS & (4)1/4"x3" SDS SCREWS TO PLATES AT 24" O.C. <br />1/2 x 8 J BOLT @ 32 O.C. MINIMUM 6 FROM O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - MOISTURE BARRIER <br />PLATE SPLICES w/ 3/16"x2" 0 PLATE WASHER SIMPSON META12 w/ (7) ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS <br />NOTE: IF EMBEDDED 10dx1 1/2" NAILS AT EA. & (4) 1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL TRUSS VERTICAL WEB (24" GABLE WEB TI SECTION 1 TRUSS X) w/ MIN. 2 <br />WEB, USE MSTAM36 w/ (7) <br />10d NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. EMBEDMENT IN KO BLOCK <br />TITEN ON OUTSIDE S5 SCALE: N.T.S. S5 <br />2x4 #2 SYP BLK'G @ 16" O.C. w/ (2)16d NAILS EA. END. <br />SEE SCHEDULE - [RSH] - ON FRAMING SHEET FOR SHEATHING <br />REFER TO DETAIL J N AND FASTENERS. (MIN. FIRST 4 BAYS) <br />ON SHEET S5 FOR r <br />X-BRACING, AND TOP r `" SEE STRUCTURAL <br />CHORD BLOCKING N _ NOTES AND NAILING <br />INFORMATION `D 00 00 SCHEDULE FOR <br />1 1 SHEATHING DETAIL BACKNAIL w/ <br />WOOD TRUSSES - _ 1/ (2} 16d NAILS <br />CO 00 00 2"x4" CROSS BRACE <br />2x4 RAT RUN BRACING APPROX. 8" FROM <br />AT 24" O.C. ON TOP OF . RIDGE FASTENED AT <br />EACH JOINT w/ (3) <br />BOTT. CHORD FOR 4 10d & (2)10d TOE <br />TRUSS SPANS NAILS @ EA. END <br />ATTACHED W/2-16d <br />AT EA. TRUSS JOINT (2) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF 2x4 PANEL BLOCKING <br />OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS @ 48" O/C FOR THE (2)16d NAILS <br />2X4 BLOCKING @ 24" " " _ " <br />(D = 0.148 , L = 3)" _ OR EQUAL (D - 0.207 , L - 41/2) OR EQUAL (D = 0.207 , L = 41/2)" FIRST4 OR EQUAL ()ROWS OF It <br />O/C w/ (2) 16d TRUSSES FROM EA. <br />TOENAILS @ EA. END NOTES: END TYP. TOP & <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL BOTTOM ATTACHED <br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) w/ (2)16d TOENAILS <br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 314 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />SPACE AS SHOWN FOR 3-PLY <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />-1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 10d NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />•2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />10dx3" @ 4" O/C <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB J <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />SIMPSON SP2 w/ (12)10d <br />2x4 LEDGER (MATCH BOTTOM CHORD DBL. TOP PLATE NAILS AT EACH STUD (2) 2"x8" "L" BRACE <br />SLOPE OF ADJACENT TRUSS) STUD WALL (SEE TYP. SEC.) FASTENED WITH (3) <br />16d PER SIDE <br />SECTION 3 SECTION 4 SCISSOR GABLE "T" BRACE 7 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 AS PER HIB 91 SCALE: N.T.S. S5 <br />MAX. 9" <br />UNSUPPORTED, <br />IF >9" SEE 10/S5 <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />_1/2" CDX PLYWOOD OR 7/16" <br />OSB SHEATHING ATTACHED <br />W/ 10d NAILS @ 6" O.C. <br />E ES AND 12" O.C. FIELD <br />14CJACK TRUSS <br />SEE PLAN FOR <br />CONNECTION <br />OF THE LAST LAMINATION ( ) 2x4 "T" ON TOP OF PANEL <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2) 16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION BLOCKING, FASTEN WITH L 2x4 BLOCKING W/ <br />EXT. WALL CONN. a� COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF 10dx3 @ 4 0/C (2)12d TOENAILS <br />NON -LOAD BEARING LOCATION B.U.C., SAME NUMBER OF ROWS, SAME SPACING ' <br />D ) SECTION g <br />SEE TYP. WALL SECTION FOR SCALE: 3/4"="-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 <br />ADDITIONAL INFORMATION. <br />IINIMUM 2x <br />'ROSS BRACING <br />SEE PLAN FOR <br />OCATIONS) TOENAIL <br />(2)16d NA <br />(2)16d PER <br />JOINT <br />.,�I..I,.�.,. �.,...,........ �.., 2"x4" MIN, SEE M/S5 <br />CROSS BRACING DETAIL <br />SCALE: N.T.S. <br />S5 <br />12 <br />6.9 MAX. <br />S5 <br />GABLE TRUSS <br />12" <br />ISH SCHEDULE <br />tTTACHMENT <br />2 SYP BLK'G @ 16" O.C. <br />i x 0.131" <br />AILS EA. SIDE <br />2x4 #2 SYP w/ 10d <br />X0.131" @ 8" O.C. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL ("I0 <br />SCALE: N.T.S. S5 <br />"L" BRACE W/ 10d @ 4" O.C. <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />S5 <br />• e ° n II ° ° a . � I l V ° l d° d < nl�m \ ° 1� . °. ° II d d. ° � ° • ° � _° s ,. °II d °d VI • a ° I) n ° ' Ila da^ <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />SCALE: N.T.S. SCALE: N.T.S. S5 <br />8d @ 6"O/C <br />\ninon ^rn� Innrn <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"X2 3/4" <br />TITEN TO CMU <br />2 x 4 BLOCKING w/ (2)10d <br />TOE NAILS AT EACH END @ <br />/\Ali -- <br />z <br />w <br />.,BRACING w/ (3)10d x 3" AT <br />EACH CONN. @ 24" O/C <br />`MOISTURE BARRIER <br />BOND BEAM <br />-MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. NON -LOAD <br />BEARING LOCATIO (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. <br />ADDITIONAL INFORMATION. <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 -i CONTINUOUS BOTTOM CHORD BRACING 2X4 MIN. <br />q11,11 <br />NOTE: ZTOP CHORD 2X4 #2 SYP BRACING <br />NOTE: ZTOP CHORD 2X4 #2 SYP BRACING <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />ZBOTTOM <br />@ 16" O.C. MAX. FOR FIRST (4) <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />BAYS <br />THAT MY BE REQUIRED <br />CHORD GABLE END BRACING <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />@ 4'-0" O.C. MAX. FOR FIRST (4) BAYS <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI <br />SCISSOR TRUSS <br />SCALE: N.T.S. <br />I <br />"L" BRACING REQUIREMENTS 2x4 BRACING @48" O.C. CONTINUOUS TO <br />OVERLAP TRUSS BRACING FIXED LOCATION ATTACHED W/ (2)10d AT <br />PRE-ENGINEERED 6" OVERLAP (1) 2"x4" (U.N.O.) 2"x6" (U.N.O.) EA. TRUSS (NOTE: BRACING MAYBE <br />WOOD TRUSSES AT LEAST TWO TRUSS SPACES STUD NO <br />SPACING "L" BRACE "L" BRACE "L" BRACE PLACED ON EITHER TOP OR BOTTOM OF <br />24" 0'0" - T-O" 3'-0" - 6'-0" 6'-0" & GREATER THE BOTTOM CORD) <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />N t <br />`-MINIMUM (2)16d PER JOINT \-MINIMUM 2X4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL M <br />SCALE: N.T.S. S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />JlrJ�� <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"xi 1/2" SDS^' ^ <br />-VVIV I. DG/'1rSIIVl7 <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />51MF1SUN SF12 W1 (12) <br />10d NAILS AT EACH <br />STUD <br />HIP FRAMING REFERENCE PLAN <br />COSMETIC DROP CEILING FRAMING <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />N <br />0 <br />N <br />N <br />0 <br />,ataatttilttatrr <br />o<�°��P LEtiVK��,f <br />O �.� • (] •� f J V • <br />7i �u <br />•.•0 \�••\�^ems <br />ri.`..` `• <br />e • <br />rj�1 t i00�! <br />�t <br />j <br />ifr <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition, Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />as <br />0 <br />^ <br />IW- <br />o O <br />c0 f� 3h <br />0 <br />N 0 C: J <L <br />-�--.� � W <br />U) <br />aajrNic <br />rntitiL W a <br />(L Y <br />ju- l_ a- W <br />z <br />r� ° <br />Wo0 <br />w <br />�O¢��¢ < <br />W <br />Z <br />co d a <br />Wrap <br />N cNiZ <br />ZOU <br />❑ ❑ ❑ <br />W <br />z N O <br />z �o <br />z o <br />J <br />N <br />V O <br />ij— <br />N <br />O <br />—� ,., Q <br />(J J <br />�U-) <br />Ly N <br />allW <br />U g <br />J <br />— E <br />m � <br />wI <br />= w <br />v o <br />in-_ "I <br />¢ N <br />A <br />14 <br />C::,�W <br />M <br />i ¢ <br />Z <br />I? E <br />O <br />_. <br />g <br />W O <br />z <br />�N <br />'@ <br />oa <br />Co <br />F^ <br />R0 <br />oa <br />Do <br />°a <br />z <br />N <br />9�_ <br />< z <br />.0 <br />�o <br />� Z <br />�H <br />_ <br />yg <br />m� <br />o <br />z� <br />zH <br />a�i <br />a° <br />¢w <br />zz <br />tn'� <br />CD 3 <br />0 <br />go <br />W <br />LL <br />a <br />�z <br />¢0 <br />4 <br />= <br />C:)a <br />�w <br />;o <br />toa <br />zzIa <br />0 <br />c O <br />= <br />6 <br />0 <br />ca <br />L <br />Al <br />W <br />� <br />0 <br />O <br />O <br />'� <br />^ <br />0 <br />o <br />v <br />I— <br />m <br />O <br />�../ <br />r <br />d. <br />r <br />2 <br />0') <br />p <br />M (0 <br />�(") <br />rn <br />E <br />'EM <br />N <br />o <br />z <br />Z <br />E <br />E (D <br />� <br />C <br />0-U <br />—1 <br />Q <br />JOB <br />NO: <br />21-2031 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S5 <br />