My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39935 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39935 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:40:24 PM
Creation date
2/19/2025 10:25:10 AM
Metadata
Fields
Template:
Building Plans
Street #
39935
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4 SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />'' MASONRY <br />WINDOW BUCK <br />4 <br />2) SEALANT JOINT <br />5) SEALANT FROM <br />r, INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />EXTRUDED SHOULDER <br />WEATHER <br />RESISITIVE <br />BARRIER <br />TAPE <br />(ABBEMBLED WINDOW ) <br />HEAD FLASHING TIE-IN INSTRUXTIC <br />1. Cut, fold up & temporarily secure t <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />DO NO- <br />BOTrO <br />FLANGE <br />^' ^ "" WEATHER <br />1/E BARRIER & <br />tARILY SECURE <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as ## in each detail that corresponds to the <br />numbered items in the list of Instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHING <br />SHEATHING BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI: <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />ED FLASHING <br />1 <br />LASHING <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />KING <br />SECTION -A (SEE DETAIL <br />q SELF -ADHERED FLASHING -/ v <br />1 O <br />2 SEAL TOPS OF JOISTS <br />8 UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />I "J <br />EXTERIOR DOOR WITH DECK <br />M <br />1 Lf1Jl IIIVV rL11J1111VV <br />2 <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROCK- <br />8" CMU <br />4"OR8"CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED - <br />VINYL SHOWER PAN <br />V-4" PER PLAN <br />SHOWER SEAT <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />Z <br />11. <br />w <br />O_ <br />U) <br />W <br />U <br />w <br />w <br />0 <br />U) <br />DOOR ROUGH OPENING <br />- 3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID <br />NAIL BRAND OR EQUAL WEATHER <br />PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />RIM JOIST <br />1� <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />10 <br />:LF-ADHERED FLASHING <br />4TCH <br />IHERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />PLASTER STOP - <br />CONTINUOUS BACKER - <br />ROD & SEALANT <br />A <br />WINDOW UNIT <br />SLOPE <br />FLASHING REQUIREMENTS <br />0.3 in: 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0,6 cm : 30.5 cm) <br />include flashing as described in Section R703.4. <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water <br />CEMT. FIN. <br />within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of <br />BUILDING PAPER <br />draining to the exterior water that penetrates the exterior cladding. <br />71 <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied horizontally, <br />77 <br />with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No.15 asphalt <br />felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building <br />71 <br />appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based <br />�_ <br />/� <br />sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />Q <br />individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in <br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />CEMT, FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER , <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />NEEDED IN CORNERS ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />R703.4 Flashing.Approved metal flashing, vinyl flashing, self -adhered membranes and mechanical) attached flexible flashing shall be applied <br />pp g' y g y g pp <br />FLASHING <br />SELF -ADHERED FLASHING <br />shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the <br />SCORED <br />entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />(BEFORE FOLDING, SCORE <br />the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />RELEASE PAPER TO AD ESIVEASSHOWN)SE <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />�i <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />door be installed in the <br />v <br />2 <br />shall comply with AAMA 712. Flashing at exterior window and openings shall accordance with one or more of <br />following: <br />5 <br />1.1 The fenestration manufacturers installation and flashing instructions, or for applications not addressed in the fenestration <br />4 <br /><> <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details are <br />not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />6 <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />SELF -ADHERED FLASHING <br />INSIDE CORNER o <br />n <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />Water Resistant Barrier <br />7.7.At built-in gutters. <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />- WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />I� 1 <br />��,#_THIS, <br />NATU <br />DO Nt <br />DRIP <br />ACCE <br />SOFFIT/CANTILEVER <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS �5 <br />RAL FRAMING <br />RAL SHEATHING <br />SAF <br />PLANE WRB <br />=AK WRB <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />1.. <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Metal <br />.. <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />O <br />N <br />N <br />N <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building <br />Code - <br />Residential 7th Edition. Engineers <br />signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />NC. <br />W <br />'IT E � t- <br />Q �00�* <br />N N <br />t? <br />O <br />m <br />CD <br />.= W N <br />J <br />* u, W <br />d <br />M <br />to <br />U)r-ra <br />- W 0- <br />°' <br />a <br />�Mv � <br />JLLi_ <br />Y <br />aLUI <br />01A <br />BRIO <br />�.�p <br />tV C0 <br />- <br />IY O J <br />W <br />��mrn <br />a a a <br />Z_ <br />LL LL <br />,n M Z <br />a <br />W rn O <br />to <br />N <br />°" <br />U� U) <br />z <br />W <br />❑❑❑ <br />cN <br />z <br />O o <br />Z MID N <br />z � � <br />Q <br />n <br />N <br />^ ' <br />M <br />z 9 <br />0 C <br />W <br />o <br />LU <br />U <br />0-, <br />-� <br />O <br />U') <br />w o <br />a--U) <br />r6 <br />U <br />W � <br />� `. <br />m; <br />E <br />Oak <br />U o N <br />• <br />Ly (n <br />® <br />A <br />r_ <br />o <br />co <br />w <br />co <br />¢ <br />0, <br />z <br />:? E <br />8 <br />W o <br />z <br />< <br />z® <br />oa <br />(o <br />UO <br />C6 <br />O E <br />X U <br />¢Q <br />az° <br />¢o <br />'O U <br />O� <br />az <br />N <br /><om0 <br />(p <br />Vi <br />_ C <br />z <br />Or <br />O <br />of <br />z� <br />m <br />I <br />2 3 <br />a <br />0< <br />zz <br />g° <br />4Z <br /><� <br />oz <br />=3 <br />5 <br />�o <br />C) <br />O <br />Co <br />w¢ <br />a= <br />OU <br />Z) ¢ <br />3 <br />.`s O <br />= <br />> Ln <br />OCD <br />(D <br />L <br />� <br />o <br />L0 <br />N <br />�> <br />a) <br />Q <br />Y <br />O <br />O <br />CD <br />04 <br />co <br />C3� <br />r <br />O <br />= N00 <br />r <br />.� <br />CO M <br />r <br />O <br />w <br />C11 <br />to <br />o <br />Z <br />co <br />Z <br />E O <br />m <br />0- <br />E <br />U � <br />.0 <br />Q p <br />C <br />_J <br />JOB <br />NO: <br />21-4269 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.