ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />#14 copper to lights & outlets <br />NEMA 1 #12 copper to 20 amp ckts <br />50 AMP/ <br />200 AMP #10-2 copper to WH <br />#10-3 copper to Dryer <br />MAIN <br />O2/0 <br />or 4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />�II <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />o <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />---/// CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: I Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FIE�W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />1-0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />kD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />T TELEVISION (OPTIONAL) <br />N 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F <br />O THERMOSTAT <br />I IMI ELECTRIC METER <br />_a ELECTRIC PANEL <br />-�^ <br />DISCONNECT SWITCH <br />^ <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />WID H.B. <br />GFI DISC. <br />111 211 <br />V!I IA <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />Lj t_-U II GU r\G\1 Gr- 1I-%,-1-G <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />DI III nGo <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=11-0" <br />N <br />O <br />N <br />N <br />CV <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building <br />Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal, <br />W <br />Q <br />,d.E <br />O M Q <br />v <br />U <br />�♦ <br />V <br />ON N <br />O <br />N 00 J <br />J lL <br />0 <br />7��1% <br />#"W <br />a <br />JLLJ <br />CHEML <br />Ju- u. <br />a L <br />0 <br />Z <br />L is <br />y <br />o <br />O W <br />J05 <br />W>NO <br />aQ00 <br />IL <br />toMZ <br />Of rnO <br />ZO <br />V <br />v�aii <br />W <br />z N M <br />o <br />Z N <br />Q <br />J <br />N <br />N <br />M <br />lzlnn M <br />_ o <br />Mcn <br />w <br />OLL, <br />�N <br />N <br />� y <br />ws <br />U Iv <br />I <br />W J <br />�— — EEo <br />Q <br />�m <br />r, <br />o <br />w <br />M <br />N <br />o <br />z <br />z <br />a <br />g <br />W <br />E <br />Q O <br />E <br />Z <br />o� <br />O <br />Y <br />QN <br />z© <br />v <br />C <br />xco n � <br />�� <br />0 <br />°a <br />ZI— <br />N<z <br />a¢ <br />wo <br /><z <br />ww <br />Ww <br />79�It <br />M <br />cn C <br />_ <br />0U <br />.2 <br />mp <br />ox <br />z <br />Q3 <br />d <br />¢ w <br />Z <br />G7 <br />N <br />F <br />o¢ <br />ao <br />man <br />y <br />y?>>? <br />mw <br /><o <br />r- <br />dZ <br />�r <br />O <br />v <br />L < <br />za <br />�0 <br />33 <br />cQ <br />0 <br />= <br />>Lo <br />O <br />CD <br />rn <br />�aca <br />0 <br />L <br />C <br />y <br />U <br />O <br />N <br />Y <br />> <br />O <br />O <br />m <br />W <br />T <br />2 N <br />I— <br />O� <br />.� <br />r <br />Lid <br />CO M <br />O <br />E <br />E <br />co <br />z <br />Z <br />E O <br />0-U <br />E o <br />a m <br />Q p <br />avi <br />J <br />JOB <br />NO: <br />21-4269 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />