<br />ABBREVIATIONS
<br />AB or A.B.
<br />Anchor Bolt
<br />FIX or FXD
<br />Fixed
<br />PWDR or Pwd.
<br />Powder Room
<br />ABV or Abv.
<br />Above
<br />FLR or Fir.
<br />Floor
<br />RA or R/A or R.A.
<br />Return Air
<br />AC or A/C
<br />Air -Conditioner
<br />FLR SYS or Ffr Sys
<br />Floor System
<br />RAD or Rad.
<br />Radius
<br />ADJ or ADJ.
<br />Adjustable
<br />FOM or F.O.M.
<br />Face Of Masonry
<br />RAG or Rag.
<br />Return Air Grill
<br />AFF or A.F.F.
<br />Above Finished Floor
<br />FP or F.P.
<br />Fireplace
<br />REG or Rec.
<br />Recessed
<br />AHU or A.H.U.
<br />Air Handier Unit
<br />FR DR
<br />French Door
<br />RECEPT
<br />Receptacle
<br />ALT orALT.
<br />Alternate
<br />FRT
<br />Front
<br />REF or Ref.
<br />Refrigerator
<br />BC
<br />Base Cabinet
<br />FT or Ft.
<br />FooU Feet
<br />REINF
<br />Reinforcing
<br />BF
<br />Bifold Door
<br />FTG or Ftg.
<br />Footing
<br />REQD or Req'd.
<br />Required
<br />BK SH or Bk Sh
<br />BookShelf
<br />FXD GL
<br />Fixed Glass
<br />RM or Rm.
<br />Room
<br />BLK or BLK.
<br />Block
<br />GALV or Galy.
<br />Galvanized
<br />RND or Rnd.
<br />Round
<br />BLW or BLW.
<br />Below
<br />GC or G.C.
<br />General Contractor
<br />RO or R.O.
<br />Rough Opening
<br />BM or Bm.
<br />Beam
<br />GFI or G.F.I.
<br />Ground Fault Interrupter
<br />RS, R/S, R/SH or R&S
<br />Rod and Shelf
<br />BOT or Bot.
<br />Bottom
<br />GT or G.T.
<br />Girder Truss
<br />SD or SD.
<br />Smoke Detector
<br />BP or B.P.
<br />Bypass (door)
<br />GYP BD or Gyp. Bd.
<br />Gypsum Board
<br />SGD
<br />Sliding Glass Door
<br />BRG or BRG.
<br />Bearing
<br />HB
<br />Hose Bibb
<br />SH or Sh.
<br />Shelves
<br />C
<br />Carpet
<br />HDR or Hdr.
<br />Header
<br />SHT
<br />Sheet
<br />CAB
<br />Cabinet
<br />HGT or Hgt.
<br />Height
<br />SHWR or Shwr.
<br />Shower
<br />CIR or Cir.
<br />Circle
<br />HH or H.H.
<br />Hand Held (plumbing faucet)
<br />SL or S.L.
<br />Side Lights
<br />CJ or C/J
<br />Control Joint
<br />HORIZ
<br />Horizontal
<br />SPECS or SPECS.
<br />Specifications
<br />CLG or Gig.
<br />Ceiling
<br />HS
<br />Hard Surface (flooring)
<br />SPF or S.P.F.
<br />Spruce Pine Fir
<br />CMU
<br />Concrete Masonry Unit
<br />ILO
<br />In Lieu Of
<br />SQ FT or SF or S.F.
<br />Square Foot (feet)
<br />COFF or Coff.
<br />Coffered or Tray Ceiling
<br />INSUL or Insul.
<br />Insulation
<br />SQ or Sq.
<br />Square
<br />COL or Col.
<br />Column
<br />1NT or Int.
<br />Interior
<br />STO
<br />Storage
<br />COMM or Comm.
<br />Community
<br />KIWALL or K/Wall
<br />Kneewall
<br />SW or S.W.
<br />Shear Wall
<br />COMP or Comp.
<br />Compressor
<br />KS or K.S.
<br />Knee Space
<br />SYP or S.Y.P.
<br />Southern Yellow Pine
<br />CONN or CONN.
<br />Connection
<br />LAUN or Laun.
<br />Laundry
<br />TB
<br />Towel Bar
<br />CONT or Cont.
<br />Continuous
<br />LAV or Lay.
<br />Lavatory
<br />TEMP or Temp.
<br />Tempered
<br />CT or C.T.
<br />Ceramic Tile
<br />LF or L.F.
<br />Linear Ft.
<br />THIKN or Thik'n.
<br />Thicken
<br />D or D.
<br />Dryer
<br />LL
<br />Lintel Length
<br />TOB or T.O.B.
<br />Top of Block
<br />DB
<br />Door Bell
<br />LT
<br />Laundry Tub
<br />TOM or T.O.M.
<br />Top of Masonry
<br />DBL or Dbl.
<br />Double
<br />MAS or Mas.
<br />Masonry
<br />TOP or T.O.P.
<br />Top of Plate
<br />DCF
<br />Decorative Cementitious Finish
<br />MAX or Max
<br />Maximum
<br />TP
<br />Toilet Paper Holder
<br />DEC or Dec.
<br />Decorative
<br />MC
<br />Medicine Cabinet
<br />TR
<br />Towel Ring
<br />DED or Ded.
<br />Dedicated (outlet)
<br />MFR or Mfr.
<br />Manufacturer
<br />TRANS WDW or Trans.
<br />Transom Window
<br />DIA or Dia.
<br />Diameter
<br />MGT
<br />Management (room)
<br />TYP or Typ.
<br />Typical
<br />DISP or Disp.
<br />Disposal
<br />MIN or Min
<br />Minimum
<br />UC or u.c.
<br />Under Counter
<br />DIST or Dist.
<br />Distance
<br />MIR or Mir.
<br />Mirror
<br />UCL
<br />Under Cabinet Lighting
<br />DMF
<br />Decorative Masonry Finish
<br />ML or M.L.
<br />Microlam
<br />LINO or U.N.O.
<br />Unless Noted Otherwise
<br />DS or D.S.
<br />Drawer Stack
<br />MONO or Mono
<br />Monolithic
<br />V or v.
<br />Valve (shower or tub/shower)
<br />DTL
<br />Detail
<br />MW or MICRO or Micro.
<br />Microwave
<br />VB
<br />Vanity Base
<br />DV or D,V,
<br />Dryer Vent
<br />NTS or N.T.S.
<br />Not to Scale
<br />VERT or Vert.
<br />Vertical
<br />DVP or D.V. P.
<br />Diverter Valve (plumbing)
<br />OE or O.E.
<br />Owner's Entry
<br />VL or V.L.
<br />Versalam
<br />DW or D.W.
<br />Dishwasher
<br />OPNG or Opn'g.
<br />Opening
<br />VTR or VTE
<br />Vent through Roof / Exterior
<br />EA or Ea.
<br />Each
<br />OPT or Opt.
<br />Optional
<br />W or w
<br />Washer
<br />ELEC or Elec.
<br />Electrical
<br />PC
<br />Pull Chain
<br />W/ or wl
<br />With
<br />ELEV or Elev.
<br />Elevation
<br />PIED or Ped.
<br />Pedestal
<br />WA or W.A.
<br />Wedge Anchor
<br />EQ
<br />Equal
<br />PH
<br />Phone
<br />WC or W/C or W.C.
<br />Water Closet (toilet)
<br />EW or E.W.
<br />Each Way
<br />PKT or Pkt.
<br />Pocket (Door)
<br />WD or Wd
<br />Wood
<br />EXP or Exp.
<br />Expansion
<br />PL or P.L.
<br />Parallam
<br />WDW HDR or WDW. HDR.
<br />Window Header
<br />EXT or Ext.
<br />Exterior
<br />PLF
<br />Pounds per linear foot
<br />WH or W.H.
<br />Water Heater
<br />FBC
<br />Florida Building Code
<br />PLNT SHLF or Pit. Sh.
<br />Plant Shelf
<br />WIC or W.I.C.
<br />Walk-in Closet
<br />FDN or Fdn.
<br />Foundation
<br />PLT HT or Pit. Ht.
<br />Plate Height
<br />WM or W.M.
<br />Wall Mounted (plumbing fixture)
<br />FG
<br />Fiberglass (Shower Pan)
<br />PSF
<br />Pounds per square foot
<br />WP
<br />Water Proof(ing)
<br />FIN
<br />Finished
<br />PT or P.T.
<br />Pressure Treated
<br />WS
<br />Water Softener
<br />FIN FLR or FF or Fin. Fir. Finished Floor
<br />PW or P.W.
<br />Pre -wire.
<br />WWF
<br />Welded Wire Fabric (Mesh)
<br />INDEX OF DRAWINGS
<br />I SHEET DESCRIPTION
<br />SHEET
<br />No.
<br />CS
<br />COVER SHEET
<br />1
<br />FLOOR PLAN
<br />2
<br />INTERIOR ELEVATIONS
<br />3.1
<br />EXTERIOR ELEVATIONS
<br />3.2
<br />EXTERIOR ELEVATIONS
<br />F1
<br />FOAM DETAILS
<br />4
<br />ELECTRICAL PLAN
<br />5
<br />ROOF PLAN
<br />6
<br />FOUNDATION PLAN MONO
<br />7
<br />ROOF FRAMING PLAN
<br />8
<br />LINTEL PLAN AND DETAILS
<br />SIN
<br />STRUCTURAL NOTES
<br />SN1
<br />DETAILS
<br />S3
<br />DETAILS
<br />S4
<br />DETAILS
<br />S5
<br />DETAILS
<br />SS
<br />RETROFIT DETAILS
<br />D1
<br />SECTIONS & DETAILS
<br />WP
<br />WATERPROOFING DETAILS
<br />PA1.0 PRODUCT APPROVAL NUMBERS
<br />PA1.1 PRODUCT APPROVAL NUMBERS
<br />PA1.2 PRODUCT APPROVAL NUMBERS
<br />MEAN ROOF 15 FT, HIGH TYPICAL
<br />FOR SINGLE STORY HOMES
<br />MEAN ROOF 30 FT. HIGH TYPICAL
<br />PLAN REVISIONS FOR 2 STORY HOMES
<br />DATE VERSION DESCRIPTION THIS DRAWING AND DESIGN IS VALID
<br />FOR 12 MONTHS AFTER THE DATE IT
<br />08-20-15 1.0 NEW BASE PLAN IS SIGNED AND SEALED OR WHILE
<br />CURRENT CODE IS VALID
<br />12-8-15 2.0 ADDED VAULT. C LG . CODE REFERENCES ARE SUMMARIES
<br />OF CODE SECTIONS.
<br />12-28-17 3.0 2017 FBC UPDATES SEE FBCR (CURRENT VERSION) FOR
<br />COMPLETE CODE INFORMATION.
<br />02-21-18 4.0 ADDED GRADE BEAM 150 MPH ENG. Notice to Builder & All Subcontractors
<br />It is the intent of Designer/Engineer listed in the titleblock of these
<br />documents that these documents be accurate, providing Licensed
<br />08-27-19 4.1 ENG. REVIEW FOR 150—C MPH Professionals dear information. Every attempt has been made to
<br />prevent error. The Builder and all subcontractors are required to
<br />review all the information contained in these documents, prior to
<br />e commenceement of any wok. The Designer/Engineer are
<br />09-20-19 4.2 ADD 8-811 E L EV. FOR TR EVESTA esponsible for any plan erro sr om ss ons,or misinterpretations t
<br />undetected and not reported to the Designer / Engineer prior to
<br />construction. All construction MUST be in accordance to the
<br />12-12-19 4.3 ELEV. B EXTEND ENTRY SLAB information found in these documents. Any questions regarding
<br />the information found in these plans should be directed to our
<br />Office at (407) 880-2333 Immediately. No backcharges will be
<br />12-15-20 4.4 OVERHANG OVER SGD REV. TO 3! PER C.M. considered for reimbursement by the Designer/Engineerwithout
<br />advanced notification and approval by the Designer/Engineer.
<br />/X rl Payments will be made in accordance to the terms of the
<br />12-19-20 5.0 FBC 2020 CODE UPDATE agreement.
<br />Control of Construction Site:
<br />CO S 3 P g � °'t V omrk.r 0.0 The Designer/Architect and engineer of record (EOR) have no
<br />1A
<br />sP q r =VA,�jNG control over the construction site and shall not be responsible in
<br />`,f� any manner for control of the construction site including, but not
<br />limited to, scheduling and sequencing of work, jobsite safety, and
<br />ORDINAN6 S' ventilation of the building and thereby shall not be responsible for
<br />the indoor air quality, or the effects thereof, for any reason
<br />.�^ whatsoever. The Designer/Architect and FOR has no duty to
<br />C/ O� protect, without limitation, the residence, construction site,
<br />materials, or equipment, from moisture, mold, fungus, fire, theft,
<br />1 941 vandalism, trespass, or any other peril or condition, at any time,
<br />expressly including, but not limited to, the period of time before
<br />construction, during the construction of the project, or after
<br />construction and the Designer/Architect and FOR has no duty to
<br />take any action or preventive measures to protect such property
<br />against any such peril at any time for any reason.
<br />f
<br />0
<br />N
<br />0
<br />N
<br />CV
<br />N
<br />•• ��
<br />78750
<br />.'• No PSTA E
<br />-• -o ' , a
<br />C3 F r
<br />���`�CNA�-���% .
<br />PJ�llflllll���,
<br />To the best of the Engineer's knowledge, information and belief,
<br />the structural plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential 7th Edition. Engineer's signature and seal is only for
<br />the structural engineering portions of the drawing pages bearing
<br />Engineer's signature and seal.
<br />WCD
<br />eW!! E h
<br />O N_ m
<br />N N
<br />W0 N y LL W
<br />M rn r. o -r W a
<br />cc u W J LL a UJ of0
<br />0L
<br />—arn 0
<br />Z
<br />o
<br />0 W
<br />1% = •f6 N (D LL O J
<br />W 0 2 - C9
<br />Z N co a Z (fNQIL
<br />IL
<br />pV v�tvn
<br />Z
<br />W 0 E1 El
<br />z �
<br />o 0
<br />� N
<br />z �
<br />�
<br />v
<br />J
<br />� N
<br />r,
<br />M
<br />N z W
<br />a
<br />4-J — u-
<br />fCS w
<br />V �
<br />N N N
<br />N
<br />fa '-
<br />U m
<br />® w c
<br />� 8
<br />_
<br />�� =�
<br />U o
<br />C co r.
<br />ti
<br />o
<br />J
<br />CO Itg5 z
<br />_J J
<br />CL o
<br />w ,_ Ze
<br />>= V ao 7d
<br />~ o a �o
<br />o
<br />O a p a Z
<br />N @ co
<br />Z a
<br />iSao
<br />m0
<br />fo C a a0
<br />�a NmaW
<br />�w go
<br />mw LL
<br />C)
<br />aLL �3
<br />rp �w dF
<br />C)
<br />=
<br />J
<br />o
<br />CD
<br />ai
<br />m
<br />m
<br />0
<br />L �
<br />0
<br />>
<br />O
<br />;
<br />N
<br />,,..
<br />2
<br />C)
<br />U
<br />° 0
<br />W C
<br />E
<br />s—
<br />cc r
<br />N
<br />J.. CSC OLO)
<br />r
<br />E
<br />0')N
<br />co N
<br />N co
<br />o
<br />z
<br />cc
<br />E Q
<br />}a
<br />I]
<br />o
<br />U J _0Q
<br />J
<br />JOB
<br />NO: 21-4270
<br />SCALE : AS NOTED
<br />SHEET NO.
<br />C S
<br />
|