My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39950 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39950 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:38:29 PM
Creation date
2/19/2025 10:25:22 AM
Metadata
Fields
Template:
Building Plans
Street #
39950
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2, Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed L/360 vertical deflection, except lintels 17'-4" and <br />longer with a nominai height of 8" meet or exceed L/180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9, Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed In exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load / . 0 <br />Safe vertical load Safe horizontal load `<� <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />i <br />8F44 1 B/1 T 8F40 1 B/1 T 8RF40 0B/1T 8F32 1 WIT <br />FORM & GROUT SOLID <br />:.a, <br />CV Q <br />o � J <br />O #5 BAR CONT. <br />8F12-1 B/1T <br />(0 <br />"V" LINTEL DETAIL <br />SCALE = N.T.S. <br />IM <br />I <br />Kamm <br />TYPE DESIGNATION <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />J <br />W <br />8 F 16- B/ 1 T <br />a <br />u <br />Z <br />Lh <br />tNOMINAL.QUANTITY <br />OF <br />#5 REBAR AT <br />WIDTH <br />TOP <br />NOMINAL- <br />o <br />HEIGHT <br />MATERIALS <br />c� prir ecast intels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w1 <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#5(1)RE <br />MIN.. <br />TTOP <br />(1) REQ'D <br />CLEAR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />° <br />d O d <br />° <br />d <br />.M.U. <br />#5 REBAR AT TOP <br />° 4 <br />° <br />D <br />d° d <br />° <br />GROUT <br />MIN. (1) REQ'D <br />1-1/2"CLEAR <br />d <br />d <br />° <br />Q L, <br />n O <br />¢ m <br />4 <br />C.M.U. <br />° <br />5 REBAR AT <br />= � j <br />° <br />O <br />BOTTOM OF <br />r cn Z w <br />0 <br />LINTEL CAVITY <br />o U ('0Q <br />\ <br />-BOTTOM <br />U ot 00 <br />v <br />REINFORCING <br />Z <br />a ¢ d co J <br />7-5/8"ACTUAL <br />PROVIDED IN <br />z LL O W 'r' <br />¢ Ci m <br />Oa <br />D D <br />�o �o <br />#5 REBAR AT BOTTC <br />AS INDICATED <br />40MINAL WIDTH 7LLINTEL <br />(VARIES) <br />on M cr <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting, <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />O O <br />4'-6" LL 4'-6" LL <br />O <br />5'-10" LL <br />LINTEL PLAN - ELEV-Al <br />SCALE: Y4"=1'-0" <br />1. <br />z-J <br />� <br />c? <br />0 <br />CV <br />N <br />M <br />C7 <br />�r..�L^ Epp tNh G� 1°eee <br />�:�• FE78750 <br />• <br />• <br />No <br />s <br />ST <br />l • <br />I``�� <br />`gyp <br />t.,t S:ti4 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineers signature and seal. <br />M <br />W <br />QO <br />� <br />n <br />v E co � <br />O 8 f0 r-* <br />C] N N � J <br />N � LL <br />C <br />0 C1 <br />J <br />G 20 1', ",- w <br />H <br />cn I- r- a � w a <br />M LL 4' Y <br />Q <br />ui <br />j LL LL a Lu <br />Z <br />� mom_ 00 <br />Wo <br />IE -9 W <br />03 r- m o <br />Z <br />LLW <br />00 d a <br />2 <br />N Cl) Z W y O <br />00��� <br />W <br />❑�❑ <br />z N o <br />z D <br />IR <br />Z r; <br />Q <br />J <br />Cl- <br />ti <br />cNi <br />In <br />n' <br />Z <br />c <br />W <br />U1 o <br />a--+ <br />(� <br />a <br />w <br />OLL <br />o <br />Vi <br />c Cq <br />�N <br />(6 <br />r- co <br />all <br />U c <br />w j <br />r - E <br />m 8 <br />_L.. °t <br />L <br />Q co Y <br />u 0 <br />0 <br />r. Q <br />N O� <br />O <br />Cl)0 <br />O <br />Z <br />z <br />¢ <br />L_ <br />Q E <br />0 <br />Zo <br />-0 <br />>ZO <br />Z <br />co <br /><S <br />6 <br />Ro <br />a ¢ <br />00 <br />o <br />00 <br />O E <br />N fV <br />dp <br />¢o <br />¢o <br />d <br />rW <br />L <br />roo <br />�Z <br />o< <br />Z <br />g0 <br />W <br />N <br />a <br />y w <br />0 <br />aE <br />=3 <br />�w <br />X0 <br />O <br />C <br />Li <br />z¢ <br />20 <br />a <br />0tZ 3 <br />>L <br />J <br />O <br />�t <br />0 <br />U <br />O <br />CV <br />.-. <br />> <br />mV <br />`0 <br />H <br />N <br />0 <br />r <br />co <br />= 04 <br />r <br />LO <br />_ CD <br />rn LO <br />T <br />E <br />E N <br />`N � <br />Z <br />Z <br />E o <br />FL <br />U � <br />Q p <br />JOB <br />NO: <br />21-4270 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />