Laserfiche WebLink
CORNER OF <br />HOME <br />GARAGE SIDE <br />Backer and Filler Block Dimensions <br />BCIOJoist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />6500s 1.811.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x T + 5/8" or 3/4" wood panel <br />.902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blockina—, <br />1/8" gap <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING )/8" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 pif max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />1/16 <br />code for appropriate <br />ZOne <br />details in <br />10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />10 -011 <br />at bearing. <br />TANK -LESS W/H <br />5'-0" <br />STUB -OUT FOR <br />GAS METER O <br />O <br />H C G <br />O O O <br />a _ <br />Ro <br />1'-0" 0 9 ' <br />o L <br />� U <br />i <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2)16d TOENAILS <br />2"X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR 3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />T X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15-4" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />*TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block / <br />(2x4 minimum) 1 <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />v'/ Provide adequate bearing <br />for each lapped joist. <br />10d nails SECTION @ INT. BRG. WALL <br />N.T.S. <br />i `V IVLLJ lL/\VLr MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />—\,,DO NOT cut, notch <br />or drill flanges <br />FILL CELL STD. 90° HOOK BOND BEAM <br />w <br />CONT. #5 > STD. 90° <br />HOOK <br />BAR <br />CONT. #5 <br />BAR <br />— #5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap ?min. <br />2" <br />max. � 4 max. <br />Q <br />Clinch nails <br />when <br />possible <br />Tight fit u <br />2x4/Plywood/OSB web stiffener <br />required when indicated or <br />- Hangers with side nailing. <br />- Hangers with sides not containing <br />top flange of joist. <br />- Birdsmouth cuts. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />I 16"" A 1%" ROUND HOLE MAY <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />DO NOT CUT HOLES <br />LARGER THAN 1Y2" <br />ROUND IN <br />CANTILEVERS. <br />$ g <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE, USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %'- KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />When joists meet over wall, provide <br />—1 3/4" minimum bearing for each. <br />2" min. <br />4" max. <br />WEB STIFFENER <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series Depth End Intermediate <br />® <br />BC1 5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3 Sd <br />14" <br />2-8d <br />5-8d <br />BCI60008811-7/8" <br />BCI6500s0 <br />9-1/2" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s0 <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190s(5 <br />11-7/ " <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPS( <br />w/(22)' <br />NAILS 1 <br />5/81 <br />THRU <br />BOLT <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />fl <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />Ja <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install tight to top flange. <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiff ner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM-/ ° <br />SEE PLAN FOR °• ° . • <br />FOUNDATION INFO ° c. 4' <br />STEM FOUNDATION <br />GRADE <br />- a <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />REINF. SEE PLAN <br />(2) 45 REBAR <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />I HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4' 0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION <br />Q n a / <br />•' a'd a <br />s Z � •'a � • .. . <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4' 0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4 a a as A ea G <br />a <br />—,I[ � a •. Ili_ <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />N <br />0 <br />N <br />CV <br />CV <br />`��kSOQ:FlO/I�! <br />M <br />0 <br />i <br />No PE78750 <br />'� �• <br />F ' LU <br />'• STA O <br />©'' FCD• <br />-� <br />.: err: <br />`` <br />'��' <br />e �10 N y�1t <br />13; <br />Mst <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />I-,O <br />�' <br />IV, <br />1m <br />N N m <br />orp <br />N# J <br />0 <br />M <br />to CO Co N <br />� LL W <br />a <br />a <br />rntiti'0 <br />N m! <br />LLw <br />a Y <br />0O <br />m LL LL <br />d L <br />Z <br />0o <br />It <br />Cr <br />3@�� <br />Xo� <br />Wog°'°' <br />rn <br />Qaa <br />Z <br />L& <br />a <br />_J <br />Z <br />N M Z <br />O U <br />U <br />W <br />ao❑ <br />Z N M <br />0 0 <br />z W <br />z o <br />J <br />V) <br />N <br />t+J <br />z 8ol <br />= <br />0+� <br />C9 0 <br />— u_ <br />+.- <br />C6 <br />w <br />o <br />U <br />.� <br />(D <br />w o <br />,U <br />v I <br />(.— N <br />I. <br />U <br />mi,....,.. <br />W J,T <br />L <br />= w <br />U oo N <br />c iu <br />¢ � � <br />° <br />12 <br />N � <br />sm <br />t• <br />o <br />�W <br />M <br />o , <br />Z <br />2 <br />U_ <br />E <br />K <br />T O <br />1? <br />E Q <br />¢U <br />oa <br />V0 <br />I— C <br />_ <br />�U <br />a¢ <br />0OU <br />o� <br />0 E <br />CN <br />0 <br />¢o <br />tZ <br />¢w <br />Cn� <br />o�w <br />U <br />Z <br />_ <br />J <br />;m <br />,w <br />Cn <br />a`ni <br />' <br />¢mz <br />$ <br />LLa <br />Z <br />gz <br />N w <br />Cs� <br />w� <br />=3 <br />> ° <br />CDC <br />z¢ <br />a <br />0U3 <br />E2 <br />J <br />'U") <br />O <br />rn <br />cc <br />cc <br />L <br />U <br />O <br />N <br />Q <br />Y <br />> <br />° <br />O <br />m <br />0 <br />CD <br />E <br />� <br />r— <br />ca <br />= N <br />s— <br />� <br />—�• <br />N <br />r <br />� <br />E <br />3 O <br />cN M <br />z <br />Z <br />r_ <br />E Ocn <br />E <br />a.0 <br />-1 <br />Q cc <br />JOB <br />NO : <br />21-4270 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />