My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39962 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39962 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:03:47 PM
Creation date
2/19/2025 10:25:32 AM
Metadata
Fields
Template:
Building Plans
Street #
39962
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
2032
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19 <br />HEEL <br />T.O.M. iv <br />F.FL. <br />12 <br />5� <br />4' RIDGE VENT <br />12 <br />7�5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />`/ --- <br />1" x 9" SMOOTH <br />TEXTURED <br />HEAD/BAND <br />------------- <br />FRONT ELEVATION - 131 <br />12 <br />zz::::� 5 <br />SCALE: 1 /4"=1'-0" <br />18' RIDGE VENT <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />''-- — — <br />_ T.O.M. <br />HDR HGT. <br />3'-0' TEXTURED TEXTURED <br />CEMENTITIOUS <br />CEMENTITIOUS <br />FINISH ON C.M.U. _ <br />FINISH ON C.M.U. (TYP) ao w <br />(TYP.) to <br />LEFT ELEVATION - B 1 <br />SCALE: 1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />q1 <br />C <br />n/ <br />k �= <br />0 <br />N <br />M <br />`••••�*� <br />M3 �E�ST�C <br />r <br />• � 1yy <br />y�� <br />P !!!ad <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's <br />signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />FW <br />of <br />� <br />ti <br />� 2 <br />N <br />N N � <br />22 J <br />Q <br />... W O <br />_u,W N <br />Sk u; W <br />M <br />Q <br />Cl) rrL <br />N M V <br />LL w a <br />+ a Y <br />JLLw � <br />aLu Z <br />0 <br />z <br />r� <br />0a <br />00: <br />•ro�m <br />m 0 <br />W <br />¢ CL <br />Z <br />oo ci <br />L mZ <br />a <br />�cn0 <br />Z <br />N QLL <br />OU <br />V J fn <br />W <br />❑❑❑ <br />U <br />z N o <br />o <br />Z N <br />z o � <br />V) <br />N <br />M <br />z <br />� <br />U o <br />u- <br />4--1 <br />W <br />� <br />U <br />O <br />0 <br />WRAI o <br />U <br />W i <br />(J o <br />• <br />o <br />N 0) <br />I� <br />a <br />W <br />M <br />M <br />J <br />y ¢ <br />o <br />2 <br />LL <br />z o <br />> <br />o <br /><o <br />Z® <br />CO <br />t-- � <br />� <br />XtUj <br />Uo <br />QU <br />Zt <br />N M <br />¢ o <br />¢o <br />w Z <br />� <br />�� <br />�Y <br />U <br />°� <br />mo <br />' <br />Z <br />Z� <br />N <br />S� <br />�z <br />oa <br />ao <br />� <br />mw <br />U <br />�g <br />K <br />o <br />w� <br />>o <br />z¢T3 <br />a <br />2 O <br />i <br />i� <br />m <br />m <br />0 <br />W <br />O <br />•> <br />CD <br />N <br />.-. <br />Q <br />> <br />o <br />C:) <br />m <br />� <br />T� <br />T <br />v <br />cU O <br />C� <br />N � <br />r <br />= <br />rn N <br />T <br />E <br />O <br />M <br />f6 <br />c <br />O O <br />N <br />Z <br />E <br />ai <br />a- <br />o <br />U _J <br />Q p <br />—r <br />JOB <br />NO: <br />21-4271 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.