My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39962 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39962 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:03:47 PM
Creation date
2/19/2025 10:25:32 AM
Metadata
Fields
Template:
Building Plans
Street #
39962
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
2032
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7, Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W P <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT -TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />;O� <br />P.ELECTRIC <br />EXHAUST FAN/LIGHT COMBINATION <br />DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F9 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />0 <br />TELEVISION (OPTIONAL) <br />T©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />owl_ <br />ELECTRIC PANEL <br />—emu <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L r J <br />OPT. CEILING FAN <br />G�) <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />#14 copper to lights & outlets <br />NEMA 1 <br />150 AMP/ <br />01 #12 copper to 20 amp ckts <br />200 AMP <br />00 #10-2 copper to WH <br />t1 <br />10 #10-3 copper to Dryer <br />V <br />TR1 <br />V <br />0 0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND Disconnect <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER 71 WITH CODE APPROVED <br />NEC 14, 250.94 ��J// CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />'it2lt'1 <br />` R <br />I <br />I <br />klTc�t_ <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />\ ® — <br />\ { _ I I VERIFY LOCATION _IRRIGATION <br />\\\ i �— ELECTRICAL PANEL <br />I I I I I I <br />OPT. <br />\\\\ FAMILY FW i GF - - D. - - W. - <br />�� 2 CAR GARAGE <br />\\ 12 <br />ROUGH IN FOR <br />\\k% OPT. CLG. FAN/ \ <br />LIGHT PRE -WIRE -r FI — <br />\\\� OPT. \ = I I I <br />_ �„ z— d _ �- I -S -� _ J cn 1 GARAGE I I <br />3' 4_ r GFI @ I DOG I I I <br />I -- — 44" <br />limp <br />A.F.F. a JI <br />i <br />I I I <br />GFI GFI I /1 <br />U.C. SWITCH i I 1 I FOR DISPOSAL I <br />f jl � 1l�I 1 I I <br />I II <br />F - V-' ENTRY <br />—69 iI <br />IIIIlI <br />G1 WHO GFI @44" LI -----_-----_ <br />A.F.F. PATIO I D.W. <br />I I <br />------- <br />CAFE'Ih �GFI � 3 3 3 <br />DEDICATED RECEPTACLE ------- <br />I I <br />FOR MICROWAVE RANGE I I <br />HOOD PER SPECS ` ` ` FOYER I I <br />_ _ I I <br />g(%GGFIdb <br />db <br />I I <br />C.M. ------ <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — <br />1I1t/.I.C. I C.M <br />S.D.qp <br />/ I U I S.D. <br />0 S.D. <br />S.D. <br />OWNER RECEPTI BEDROOM 3 <br />/ SUITE FOR I ROUGH -IN FOR <br />ALA/ M I <br />-2--/ S ST M I OPT. CLG. FAN/ _ BEDROOM 2 <br />/ LIGHT PRE -WIRE <br />-- — r\\ 12 �' �� %ROUGH -IN FOR <br />4 / / OPT. CLG. FAN/ <br />DISC. I ROUGH -IN FOR i G c" \� �,/ LIGHT PRE-WIRI <br />OPT. CLG. FAN/ <br />WP I LIGHT PRE -WIRE <br />GFI =VP <br />AC PAD FI VP o► <br />(:A <br />ELECTRICAL PLAN — ELEV—B1 <br />SCALE: %4"=1'-0" <br />N <br />0 <br />N <br />N <br />N <br />co <br />O <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building <br />Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />MW N <br />4 <br />g <br />R <br />(0 <br />-4 <br />rp LL <br />19 'n <br />Lu <br />Q <br />�M0 <br />� a• Y <br />jLLu_ <br />ui <br />a w � <br />Z <br />0 <br />L 0 <br />'co N to <br />rY O <br />W <br />C/5 <br />¢ Q a <br />Z <br />L IL <br />N c) <br />a <br />�D p <br />Z <br />O U <br />V_j 0 <br />0 <br />(D <br />z N M <br />o <br />z <br />0 <br />z <br />J <br />a <br />- N <br />M <br />z u_ <br />/ rl <br />0 <br />w <br />ON <br />�J O <br />2 <br />LU <br />o <br />U <br />O—� <br />w g <br />U <br />w� <br />f-- J E <br />ml' <br />x' <br />3 <br />U f/! <br />¢ 0 <br />0 <br />N <br />r, <br />CC) <br />W <br />Co <br />z9 <br />o <br />z <br />Z <br />JL <br />z o <br />00 <br />� <br />> <br /><N <br />4� <br />U <br />O <br />Ca <br />(10 <br />a <br />ao <br />x c¢�i <br />O <br />OD lj <br />O< <br />Z <br />O <br />N <br />ao <br /><o <br /><o <br />aZ <br />d <br />ra <br />�S <br />m� <br />oZ <br />z <br />Z�g <br />J <br />0'8 <br />¢w <br />z <br />rn <br />w <br />Z <br />5Z. <br />°LL <br />a <br />�w <br />W>z <br />U <br /><Z <br />}� <br />NZ <br />� <br />=3 <br />r70 <br />>O <br />Mill <br />o <br />c0 <br />w;s <br />a <br />0 <br />c O <br />E <br />> d' <br />rn <br />0 <br />L <br />C <br />0 <br />0 <br />O <br />Q <br />Y <br />0 <br />OL <br />*o <br />C m <br />CU <br />o <br />� <br />L/ <br />E T <br />`o o <br />r <br />Lo <br />= N <br />r <br />I.n <br />CV a' <br />Ln <br />r <br />= <br />w N <br />rn <br />EO <br />N <br />C'7 <br />0 <br />z <br />to <br />Z <br />O <br />n <br />E <br />U <br />Q p <br />JOB <br />NO: <br />21-4271 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.