My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39970 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39970 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:28:30 AM
Creation date
2/19/2025 10:25:46 AM
Metadata
Fields
Template:
Building Plans
Street #
39970
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
2015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•! MV 1 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />00 III � <br />#14 copper to lights & outlets �RJ I V <br />150 AMP/ #12 copper to 20 amp ckts <br />200 AMP 00 #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />/0 o <br />200 amp <br />150 amp r 4/0 SER Alu <br />UNDERGROUND i onnect S POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />FEA <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />Fr=tG.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />& <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />Qt <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />Pl a <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60• A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />Ja <br />ELECTRIC PANEL <br />_Mai <br />DISCONNECT SWITCH <br />%�� <br />G J <br />ROUGH -?IN FOR OPT. CEILING FAN <br />�� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />VERIFY METER LOCATION <br />WITH BUILDER <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE:1/4'=1'-0" <br />N <br />N <br />N <br />N <br />M <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building <br />Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />in <br />a <br />E <br />CCD) g 8 <br />n <br />r <br />m r` <br />1A <br />N <br />0' C <br />N <br />f J <br />J u- <br />0 <br />0 <br />e+ <br />g ,n co <br />�C'40 <br />at LL a <br />LL <br />ati <br />M v <br />JLLtL <br />rL <br />X <br />a. w <br />0 <br />ig <br />W <br />Ze�GWog <br />rpji�O' <br />a-j <br />Z <br />N N Z <br />a <br />tY L. 0 <br />Z <br />O U <br />U y <br />W <br />❑ao <br />V M <br />Z Cl) Cl) <br />Z <br />Z r` <br />J <br />— N <br />X4—j <br />LL <br />1 <br />1' ` <br />CD t0 <br />UM <br />g <br />0 <br />— <br />W s <br />�N <br />' <br />+J <br />`- e <br />8 <br />! <br />Zr <br />2 <br />< 0 <br />_ � <br />sm <br />o <br />co <br />M <br />Z <br />w <br />Z <br />U- <br />c6 E <br />o <br />Z <br />R <br />> N <br />O <br />E 8 <br />cuCL <br />�0OL <br />Z® <br />F— <br />— <br />08 <br />as <br />oU <br />O <br />Z <br />O E <br />CV <br />�o <br />o <br />ao <br />ai <br />w <br />L <br />ra <br />C <br />C <br />o <br />y� <br />m0 <br />F o <br />°LL <br />Z, <br />ZCO <br />J <br />Lu <br />ZZ <br />(�- <br />fA <br />a) 3 <br />�a <br />og <br />°� <br />5o <br />�w <br />W <br />WoK <br />O <br />CD <br />x <br />IIIIIIIIII� <br />Cfl <br />Nr <br />�w <br />z¢ <br />a F <br />0U3 <br />U)L <br />J <br />rn <br />m <br />m <br />0 <br />L <br />� <br />i <br />v <br />N <br />i•... <br />j <br />0/� <br />U <br />O <br />C m <br />I\ <br />C: <br />E <br />L <br />r <br />� <br />ca N <br />= <br />r <br />Ln <br />2 00 <br />N <br />r- <br />T <br />O <br />pO^j <br />0 <br />E_ <br />M N <br />z <br />cc <br />z <br />E <br />co0 m <br />cc <br />M <br />o <br />E .. <br />U -1 <br />v 43 <br />Q 0 <br />c <br />� <br />JOB <br />NO: <br />21-4272 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.