My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39981 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39981 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:33:49 AM
Creation date
2/19/2025 10:26:04 AM
Metadata
Fields
Template:
Building Plans
Street #
39981
Location
Harmon Grove Ct
Contractor
Lennar Homes
Building Plans - Permit #
2150
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R <br />59'-4" <br />30'-10" <br />A <br />H.B. S3 O <br />25-SH <br />R&S - --- -- EGRESS <br />------------L--- --- 4-SH <br />AC PAD -- -- T - <br />�, rBE�D�ROOM 2 <br />W . 1. C. 1---�---- -FLATCARPET LG. <br />I--- -.-. _- L- = <br />00 8'-0" FLAT CLG. T Mb <br />CARPET 50 <br />.� <br />_ -O"`FL - <br />---------2668 ----- <br />R&S I TILT <br />II i <br />O12'-8" -21 i - -10 1 V-4" <br />Aco <br />2 (n R riN <br />Cn w ._.. _ .__... _ e? <br />0 o?4068 B.F. N <br />wVF CO FIBERGLASS s s„ <br />SURROUND in 8-3" 43'-84 <br />I O <br />N <br />60" X 36"------- R&S - - - - - ih <br />9 A SHOWER <br />S3 <br />16" DEEP <br />1STORY TYP O - �- <br />PANTRY --- <br />w 8-4'9 30 30 9 <br />OWNER'S �o SAT LG. RA G - T <br />rr'= i-TIL - -i _ - - <br />N <br />00 <br />SUITE N1--- NF 9'-4FLAT L-- <br />8'-0" FLAT CLG. ' G. L- <br />" - - - - �- -- - <br />o CARPET I <br />A I 2'16" - 2"F- - - -- 9' 23" 8''-5o <br />O v� <br />N <br />00 <br />4 2x4 #2 SYP DISP <br />- �II� -� INK '� <br />T <br />S UDS W/ US <br />P I <br />HTT4@ BASE S3 I I ��---- ! D.W. o o - <br />00 law 0 0 <br />o I Ip � I ---- ----J of <br />C14-t- r=_____-__ <br />V J <br />S-0" 1'-5s G HANS N <br />S3 BOX @� <br />A.F.F. <br />9'-0" I 3'-8" 2'-8" 4'-3" 6'-10" 3'-7" <br />I <br />I <br />2.12 SLOPE. I `D <br />CEILING <br />I <br />o I <br />00 O �00 <br />I I <br />PATIO � <br />FAMILY ROOM <br />4'-0 VAULT. CLG. CAFE <br />" / CARPET VAULT. CLG. <br />30'-0" <br />/ CARPET <br />M. <br />at.- <br />Oz LO Oz <br />UJ U)J <br />fU Tw <br />A <br />S3 <br />35-S H <br />O <br />T-1 <br />O <br />25-SH <br />EGRESS <br />BEDROOM <br />8'-0" FLAT CLG. <br />CARPET <br />0'-4" <br />HALL <br />9'-4" FLAT CLG <br />CARPET <br />LAT C <br />FIBERGLASS <br />SURROUND <br />n <br />r d <br />K <br />S3 <br />11'-10" <br />1 2668 1 <br />20'-8" <br />BEDROO 14 <br />8'-0" FLAT CL <br />CARPET <br />T-0" 9. 84.. <br />3" 40681 B.F. <br />r00 <br />- - - - - -------- <br />N G.T. <br />EK------- <br />s3 r---- <br />I <br />I I <br />I <br />I <br />I � <br />I 0 <br />I I <br />I � <br />I <br />2-CAR GARAGE <br />o <br />8'-0" FLAT CLG. <br />I <br />w <br />I <br />EDGE OF SLAB 2"I�BEYOND <br />WALL <br />WI <br />FDREURVENT <br />I <br />O <br />ROOF <br />I <br />I <br />20'-9" <br />II A I I I <br />I 11 I 1 <br />INIv� I I <br />I <br />Ia�l I <br />I <br />III 11 I I <br />I <br />L- - - - t ------- <br />I I <br />I <br />30681 I <br />D ENTRY <br />v 1 8'-0" FLAT CLG. <br />CO = <br />Cn <br />we O 00 <br />� co <br />C7 T' <br />w <br />A \ <br />H U <br />IN <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />187X2572 <br />S.H. <br />13 <br />20X38J <br />18-IX37 <br />S.H. <br />14 <br />20 X 501 <br />1812 X 50 <br />S.H. <br />15 <br />20X63 <br />184X62J <br />S.H. <br />16 <br />20X72 <br />18,X71 <br />S.H. <br />11-12 <br />271/4X26 <br />26X25J <br />S.H. <br />11-13 <br />271/4X38i <br />26x3711 <br />S.H. <br />1 H4 <br />27 1 X 501 <br />26 x 50 <br />S.H. <br />11-15 <br />27JX63 <br />26X621/2 <br />S.H. <br />11-16 <br />2771X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S. H. <br />23 <br />37 J X 38 J <br />36 J X 37 3/4 <br />S. H. <br />24 <br />37 J X 50 $ <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 X 62 1/2 <br />S.H. <br />26 <br />37JX72 <br />36 X711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 i WIDE <br />S.H. <br />32 <br />54 X 26 <br />521 X 25 7 <br />S. H. <br />33 <br />54 X 38 i <br />52 4 X 37 J <br />S. H. <br />34 <br />54 X 50 J <br />52 4 X 50 <br />S. H. <br />35 <br />54 X 63 <br />52 J X 62 J <br />S. H. <br />36 <br />54 X 72 <br />52 2 X 71 z <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Table R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />rAA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />O <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />O <br />SEE SN SHEET O SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />INTERIOR BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION <br />1ST FLOOR LIVING AREA 1817 <br />LIVING TOTAL 1817 <br />21'-5" 16'-3" 4'-8" 1'4" <br />37-8" 6-0" 15'4" GARAGE 427 <br />FRONT ENTRY 32 <br />59'-4" <br />TOTAL AREA 2276 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />FLO R PLAN - E L E V-A <br />O <br />EXT FRAME 2 x 6 <br />R-1KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />SCALE: %4"=1 r-0" <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />VHF.. 1V4`{�• / V !C <br />�� <br />... <br />CD <br />F L 0 <br />a i <br />fIElElitii <br />To the best of the Engineers knowledge, info oration and belief, <br />the structural plans and spedfications <br />contained within these <br />drawings comply with the 2020 Florida <br />Building Code - <br />Residential 7th Edition. Engineer's <br />signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />Q <br />n <br />E Co <br />co <br />O M 8 N Yk <br />v <br />ON N � J <br />C)_ <br />0 <br />' 2 <br />� ,n ao � �t ", w <br />a <br />N <br />to <br />a <br />cn�r`� J w <br />CJ ID u_ a Y <br />n <br />LL a Lu <br />o <br />Z <br />_ <br />`6_j <br />�/ <br />1% <br />c ca C)i-w <br />: 'F CV UJ m - J <br />¢ <br />Z <br />LL <br />oo a- <br />Lo <br />M z 0: N O <br />z <br />N < 0 <br />O U U <br />CD <br />0 <br />z <br />IR <br />�/1 <br />z <br />d ?, <br />J <br />M <br />� <br />z <br />� a <br />� <br />a) <br />4--J00 <br />U <br />in m <br />a <br />V":5 <br />O <br />�N <br />O� N <br />=12 <br />w.. <br />-u J <br />H _ E <br />U <br />o"• <br />rJ o N <br />c u) <br />aD o <br />O <br />o <br />N <br />ti <br />O <br />(O <br />J <br />w <br />M <br />z <br />o <br />z <br />< <br />c E <br />(a_of <br />0 <br />�o <br /><a <br />z© <br />i- 6 <br />CL <br />OE <br />N no <br />Ko <br />�¢ <br />o <br />�o <br />uOU <br />o <br />o <br />E_ <br />N i <br />� <br />ao <br />�w <br />rp <br />cn <br />o <br />U <br />mo <br />o <br />o f <br />lo <br />N m <br />Q W <br />zz <br />Zo <br />U <br />Q � <br />a <br />7 <br /><(� ¢ o <br />= <br />o z <br />3 <br />=r <br />v <br />zo <br />a <br />0 <br />c � <br />Lo <br />0 <br />m <br />0 <br />L <br />1` <br />o <br />M <br />' <br />U <br />r <br />Q <br />Y <br />C:)0 <br />n <br />m <br />V/ <br />N <br />O <br />E <br />d- <br />T <br />(o r <br />2 <br />Vi <br />r <br />Cy <br />I C'7 <br />Ln <br />r <br />0') LO <br />E <br />T- <br />'E (V <br />C'M d <br />o <br />z <br />M <br />z <br />E O <br />(n <br />u <br />a <br />E <br />o <br />U J <br />Q p <br />J <br />JOB <br />NO: <br />21-5015 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1 <br />ITIT <br />
The URL can be used to link to this page
Your browser does not support the video tag.