My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39981 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39981 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:33:49 AM
Creation date
2/19/2025 10:26:04 AM
Metadata
Fields
Template:
Building Plans
Street #
39981
Location
Harmon Grove Ct
Contractor
Lennar Homes
Building Plans - Permit #
2150
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />FiF <br />HALF -SWITCHED DUPLEX OUTLET <br />f� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�[]BD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />T© <br />TELEVISION (OPTIONAL) <br />T 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />—� <br />DISCONNECT SWITCH <br />� <br />C�' J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />1r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A <br />INDOOR <br />PANEL <br />CENTER <br />#14 copperto lights & outlets <br />NeMA 1 <br />150 AMP/ <br />#12 copperto 20 amp ckts <br />200AMP <br />10 #10-2 copper to WH <br />00 #10-3 copper to Dryer <br />METER <br />MAIN <br />O2/0 <br />or <br />410 SER AID <br />200 amp <br />150 amp <br />UNDERGROUND Disconnect <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING o #4 GROUNDING WIRE <br />TERMINATION PER 71 WITH CODE APPROVED <br />NEC 14, 250.94 J CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />SI <br />IN <br />111 � <br />2'VfRJIV <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />H.B. <br />W.I.C. ):�_ <br />I <br />I ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />1 1�, 12 <br />CC�WNER'S <br />SUITE <br />C \ <br />l <br />DEDICATED RECEPTACLE <br />o FOR MICROWAVE RANGE e <br />HOOD PER SPECS <br />---------- ---- / <br />D_W _ I — c <br />S.D. wI^O Z _j <br />1 TGI _ F-r — - - - <br />61 _�-- <br />I / <br />I Ll <br />CC.M <br />i/T— / <br />/ I <br />/ ROUGH -IN FbR <br />/ OPT. CLG. F�N/ LIGHT <br />PRE -WIRE I / <br />/ FAMILY ROOM <br />i <br />/I— —I� <br />SINKw/• <br />�— YDISP <br />I <br />/ <br />PENDANT AS <br />PER SPECS <br />&/ CAFE <br />i <br />i <br />VERIFY METER LOCATION <br />WITH BUILDER <br />BtDROOM 3 / <br />ROUGH -IN FOR /ROUGH -IN FOR <br />OPT. CLG. FAN/ OPT. CLG. FAN/ <br />LIGHT PRE-WIR� �% \ / LIGHT PRE -WIRE <br />1 I <br />PED�ObM 4 <br />I <br />S.D. <br />� III <br />):HALL1-1 S.D <br />— C.M O ,II. ---------------- <br />H.B. <br />VP <br />`H'GFI @ 44" <br />A.F.F. <br />OLU <br />Z I <br />¢� I <br />U I <br />LL I <br />Lu U I <br />W <br />w 2-CAR GARAGE <br />GFI@44" <br />A.F.F. <br />/ GARAGE 1 I <br />/ LIGHT AS IGARAGE <br />PER SPEC 'DOOR <br />IGFI <br />' — I <br />� / I <br />I <br />I 11 I I <br />I l l I I <br />I I 1�1 I <br />I <br />I <br />L------------ <br />GFI @ 44" A.F.F. <br />(0) IRRIGATION <br />\WWP <br />GFI I ENTRY <br />I <br />I <br />I <br />ELECTRICAL PLAN - ELEV-Al_l <br />SCALE: Y.-1-0. <br />N <br />0 <br />CV <br />Ln <br />0 <br />d- <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building <br />Code - <br />Residential 7th Edition. Engineers <br />signature and seal is only for <br />the structural engineering portions <br />of the drawing <br />pages bearing <br />Engineer's signature and seal. <br />H <br />C, <br />W <br />Q <br />d E <br />O <br />N <br />N N � <br />W J <br />L� <br />C <br />NN <br />co N <br />rn t-- r2 a <br />M� <br />xt W <br />J Lu 0- <br />LL a <br />a <br />0 j <br />J LL LL � <br />Y <br />LL L <br />Z <br />0 <br />— -0 rn <br />12 <br />Y <br />I� <br />122o�w <br />E 'm ri1 <br />= OZ J <br />LLW <br />co <br />Ln <br />cc '0" Z <br />IL <br />X 0 <br />N <br />O U <br />U vvi <br />7 <br />z N M <br />o g <br />z <br />N <br />z o <br />� <br />J <br />n- <br />N <br />V) <br />z a <br />vCo <br />4` <br />4-1 C„ <br />(>3 W <br />a <br />V <br />0 <br />o <br />W <br />to c N <br />aim <br />r— rn <br />U <br />W J <br />L U <br />= <br />s� <br />c, o <br />cCnY <br />¢ 0 <br />�0 <br />� m <br />ti <br />o <br />Mw <br />w <br />M <br />o <br />Z <br />z <br />e <br />g <br />J <br />E <br />CD <br />E Ov <br />�g <br />of <br />z <br /><� <br />z® <br />oa <br />V <br />U O <br />co 6 <br />o E <br />2cD <br />a z <br />o� <br />w z <br />cV <br />o <br />¢omo <br />w <br />y <br />U <br />0, <br />Z <br />z <br />rn <br />G <br />Z0 <br />Q V <br />sona <br />SEE <br />N <br />Q <br />O <br />W� <br />nw <br />oW�3 <br />=r <br />o <br /><a <br />c� <br />o <br />o <br />.0 O <br />J <br />'L <br />O <br />ai <br />m <br />m <br />CU <br />L <br />� <br />o <br />_M <br />m <br />N <br />Q <br />Y <br />'o <br />O <br />m <br />E <br />r <br />CID T <br />= <br />0') <br />0-) <br />CV <br />r <br />T_ CDLid <br />r= <br />M <br />rn LO <br />r <br />E <br />M <br />o <br />m <br />z <br />E <br />E O <br />i6 <br />z <br />N <br />a <br />E <br />0 <br />U _j <br />_0 M <br />¢ o <br />` <br />c <br />JOB <br />NO: <br />21-5015 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />I Ili II - -- - -- -- - _ <br />T- <br />