Laserfiche WebLink
L <br />Backer and Filler Block Dimensions <br />BCIOJoist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8' <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1 /2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1 /2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />1/16 <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />101-011at <br />bearing. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 00 0 <br />5'-0" a - <br />c� <br />STUB -OUT FOR o ° <br />LO <br />GAS METER 0 a <br />0 0 <br />N = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-l" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />II.ca3"f1OrIllnailsWR"nc <br />Provide adequate bearing <br />for each lapped joist. <br />10dnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES (KNOCKOUT EXEMPTS) <br />(see table below) D <br />\,� <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />FILL CELL <br />w <br />cr- <br />C> STD. 90' <br />CONT. #5 <br />I HOOK <br />BAR <br />STD. 900 HOOK <br />BOND BEAM <br />SIMPSON MGT <br />w/ (22)10d <br />NAILS TYP. GIRDER TRUSS <br />�— CONT. #5 <br />BAR 2X TOP PLATE <br />#5 CONT. THRU <br />FROM BOLT <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM STEP <br />BOND BEAM <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />III <br />INTERIOR BRG. WALL <br />ate/ TJI PER PLAN <br />OTHERWISE SOLID <br />IBLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min.) Small gap 2" min. <br />2" max. 4" max. Web Stiffener Fastener Schedule <br />ead <br />tinn <br />Series �tB End L_olntermedlate <br />2-8d 2-8d- <br />-- I BCI 5000s®I 11-7/_8" 2-8d 3-8d <br />14" 2 d8d8 5-8d 1 <br />Clinch nails - <br />(/7z <br />9-1/2 2-8d 2-8d <br />when BCI6000s®r11-7/8" 2-8d - 3-8d <br />possible ✓ BCI6500s® 14 2-82-8d 5-8d_� <br />-_- 11 6" 2-8d 6-8d i <br />11-7/8 2-8d 3-8d <br />Tight fit i BCI 60s® 14" 2-8d 5-8d <br />9 ��� <br />Ti - _ 16" 2-8dL__-6-8d <br />11-7/8"-3-1166d _ 3-16d <br />2x4/Plywood/OSB web stiffener 2" min. BCI 90s8 14 . -1 5-16d _-- 5-16d <br />required when indicated or 4" max. 16" 6 16d 6-16d <br />- Hangers with side nailing. <br />-Hangerswithsidesnotcontaining WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />pitsWhen joists meet over wall, provide <br />�1 3/4" minimum bearing for each. <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />A 1Y2" ROUND HOLE MAY J 6" 6" <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Yz" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Plumbing <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />Jc <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />_-,.Install tight to top flange. <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap —: <br />Block // <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />�� -r --, requirements <br />/ ° 0.6 X Joist <br />`depth <br />�- T _S. <br />I -JOISTS BUCKETS <br />N.T.S. <br />I.0 <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM—/ ' ' • <br />SEE PLAN FOR--'°• • . • <br />FOUNDATION INFO <br />STEM FOUNDATION <br />GRADE <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />REINF. SEE PLAN <br />(2) #5 REBAR <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />' SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />nln� I ir!nTln A I Tulnt I rKIM <br />TOP (2) #5's x 4'-0"— <br />CENTERED @ PIPE <br />PENETRATION <br />4 d. <br />/ `PVC OR SCH40 SLEEVE <br />rPLUMBING LINE <br />d L <br />A. <br />z <br />co � <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />� G ° ' .a e <br />G <br />° ° n° G <br />a .a <br />° a ° a T'r <br />SEE FND. PLN. <br />ol SIZE & REINF. <br />= < <br />••'.,, FLU........ <br />i�lliZr?0 <br />o • <br />ESS1% 0`�� <br />/1111111t'% <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />tlf <br />W <br />H <br />0 <br />v E � n <br />o # <br />Q6rNi <br />V LL Y <br />JLL LL aw <br />Z <br />� ` °' M <br />L M 8 O~ W <br />�y <br />Y. <br />j '� N f_O m OJ J <br />f <br />W <br />Z <br />un <br />00 Zp a a <br />a <br />Z <br />N co o O <br />pV UJr�n <br />W <br />❑O❑ <br />CD <br />z N M <br />z � <br />Z n <br />J <br />Q) <br />N <br />cn <br />W <br />a) <br />2 <br />1'r <br />fCS <br />U <br />N <br />LU W <br />� a <br />O <br />W s <br />N <br />C <br />) <br />m $ <br />8 <br />z � <br />• <br />Q Y <br />04 8, <br />S <br />� <br />o <br />w <br />O <br />zM <br />J <br />E <br />20 <br />WO <br />� <br />}N <br />QR <br />ZA <br />O <br />E v <br />~ <br /><. <br />20 <br />UO <br />W, <br />0° <br />z <br />O E <br />N< <br />aQ <br />zo <br />az <br />w <br />�? �a <br />¢ <br />m, <br />o <br />z�_ <br />�oz <br />U <br />N U <br />Z <br />Q W <br />N <br />< ° <br />zz <br />�J <br />3 <br />a <br />0�50 <br />� <br />a <br />N W <br />W <br />U 3 <br />aij <br />N <br />�k <br />o <br /><g <br />�O <br />a r <br />COO <br />V' <br />zla <br />° 3 <br />0 <br />c O <br />Orn <br />m <br />c� <br />L- <br />1= <br />W <br />O <br />> <br />U <br />T— <br />•- <br />(D <br />N <br />_ <br />Q <br />U <br />- <br />O <br />C0 <br />�- <br />0 <br />.� <br />-0 <br />�. <br />Lr) <br />I\ <br />"a <br />co <br />= N <br />0) <br />T— <br />N <br />= O <br />IT O <br />0) <br />to <br />E <br />c N <br />M <br />z <br />M <br />z <br />E 10c <br />ig 0- <br />ci <br />a o <br />JOB <br />NO: <br />21-5013 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />