A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />`— LINt Ur <br />STRUCTURE ABOVE <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4„ = 1'-011 <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-0" <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR TH <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />NFPA 72 2016 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS FRO GARAGE MUST BE SERVED <br />BY SEPARATE BRANCH CIRCUIT THAT DOES NOT SUPPLY <br />OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR. <br />NOTES: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR <br />SIDE -HINGE DOORS SHALL BE TESTED AND LABELED <br />WITH A PERMANENT LABEL PROVIDING TRACEABILITY TO <br />THE MANUFACTURER AND PRODUCT. <br />200A INDOOR PANEL <br />CENTER <br />10 <br />#15 copper to lights & outlets <br />1 <br />00 AMP <br />200 <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.60 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />DOOR <br />JAMB <br />TRIM <br />BASE <br />TRIM <br />_INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />-SWITCH <br />1/2" <br />DUPLEX _ <br />OUTLET <br />M <br />0 <br />0 <br />0 <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />ROUGH FRAMING <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />Q STRUCTURED WIRE OUTLET <br />- SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />--0 PUSH-BUTTON DOORBELL <br />{A - CLG MNT LT FIXTURE <br />} CLG MNT PREWIRE - FIXTURE BY OWNER <br />} SURFACE MNT FIXTURE <br />{�} WALL MNT FIXTURE <br />NOTE: <br />ND OPALEX - ALTERNATE <br />TUB/SHOWERCANS MAY BE <br />0 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />C RECESS CAN OR LED OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />ELF} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />© SMOKE DETECTOR <br />C SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24- SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />96: 24 ­B 24" VANITY LIGHTING <br />E 36 :;� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />® EXHAUSTFAN <br />p DOUBLE FLOOD LIGHT W/ COVERS AND <br />U 15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />1� MASTER STATION <br />>D ELEC PANEL <br />® VACUM OUTLET AT 12" <br />L/RAICEILING RETURN AIR (W/ SIZE) <br />® A/C REGISTER <br />C THERMOSTAT <br />® SECURITY PAD <br />In ELEC METER <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION <br />PURPOSES. <br />J <br />AA,, <br />h <br />E <br />W <br />VJ <br />i <br />>_ O ; <br />o <br />Q M N <br />(� <br />f�' <br />Y <br />—0 w <br />' <br />W <br />MOO <br />4 <br />L <br />r <br />_O <br />° u_ 8 <br />Q <br />•� <br />s <br />U6/'�� <br />iu <br />N <br />W C)- <br />c� <br />E <br />N <br />c <br />s` <br />o <br />- �a <br />5 <br />LU <br />°�(6 - w°� <br />w ELLLYZDQ M2_j w <br />�Z <br />W Q�i(J00,wN'U020�0 <br />Q Haxi0220°t-QP <br />z9zOOwOOmzj <br />0 Wa�ZIa, <br />0zYnzLLpw0Ua.° iL Z0WW�ww°QWUQ <br />Oo D<Q a <br />O <br />O <br />N <br />o"' <br />O <br />M N <br />z V) LL <br />Q (Al M L0 <br />Ln <br />F— a 0- rfj <br />Z HDO <br />J <br />w z CD <br />�O <br />d' <br />N <br />coa000000� <br />r- <br />o <br />�- <br />0 <br />� <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />N <br />N <br />O <br />N <br />O <br />N <br />o0 <br />N <br />N <br />N <br />A <br />N <br />4 <br />o) <br />6 <br />O <br />O <br />CV <br />O <br />O <br />O <br />O <br />r- <br />O <br />C <br />>1 <br />-I <br />0 <br />N <br />0 <br />eM <br />0 <br />1 41 <br />0 <br />LO* <br />0 <br />1 (D <br />0 <br />Lam. <br />LZ <br />Z Z <br />Z O <br />Lu <br />�wv� <br />Uo>o <br />�— <br />0 <br />X LLI <br />.� <br />�� <br />z <br />ZwI-Q <br />H <br />=m0Z <br />OzW <br />Q <br />Z <br />Z Z LL <br />LU ILU <br />Og2z <br />MF <br />Q w <br />U <br />SQ Z z <br />• <br />Z T__1 <br />Z0 <br />2¢O <br />~ U <br />V <br />O <br />a <br />W <br />� <br />z <br />A6 <br />Z <br />w <br />LL, <br />N <br />LAST PLOT DATE <br />o <br />May. 4, 21 <br />1 ST & 2ND FLOOR <br />z}' <br />0 <br />J <br />ELECTRICAL PLAN <br />B <br />