Laserfiche WebLink
ABBREVIATIONS <br />ABV -ABOVE <br />AFF - ABOVE FINISH FLOOR <br />AHU - AIR HANDLER UNIT <br />A/C - AIR CONDITIONING <br />ALUM - ALUMINUM <br />AT - ALUMINUM THRESHOLD <br />AB - ANCHOR BOLT <br />AVG -AVERAGE <br />BFE - BASE FLOOD ELEVATION <br />BM -BEAM <br />BLK -BLOCK <br />BLDG - BUILDING <br />BRD -BOARD <br />BRG - BEARING <br />BTM -BOTTOM <br />BUC - BUILT UP COLUMN <br />CAB - CABINET <br />CD - CONSTRUCTION DOCUMENTS <br />CLG - CEILING <br />CLG HT - CEILING HEIGHT <br />CEMT - CEMENTITIOUS <br />CL - CENTERLINE <br />COL -COLUMN <br />CONC -CONCRETE <br />CMU - CONCRETE MASONRY UNIT <br />CONST - CONSTRUCT OR CONSTRUCTION <br />CONT - CONTINUOUS OR CONTINUES <br />CTR -CENTER <br />CJ - CONTROL JOINT <br />DP - DEEP OR DEPTH <br />DTL - DETAIL <br />DIA - DIAMETER <br />DIM - DIMENSION <br />DISCON - DISCONNECT <br />DW - DISHWASHER <br />DR -DOOR <br />DBL -DOUBLE <br />DWG - DRAWING <br />EA -EACH <br />ELEC - ELECTRICAL <br />ELEV -ELEVATOR <br />EQ -EQUAL <br />EQUP -EQUIPMENT <br />EXP JT - EXPANSION JOINT <br />EXT - EXTERIOR <br />FIN FLR - FINISHED FLOOR <br />FIN - FIN <br />EW - EACH WAY <br />FG - FIXED GLASS <br />FD - FLOOR DRAIN <br />FE - FIRE EXTINGUISHER <br />FLR - FLOOR <br />FLOUR -FLUORESCENT <br />FTG - FOOTING <br />FR DR - FRENCH DOOR <br />GALV - GALVANIZED <br />GA -GAUGE <br />GB - GRAB BAR <br />GFI / GFCI- GROUND FAULT CIRCUIT INTERRUPTOR <br />GLS -GLASS <br />GWB - GYPSUM WALL BOARD <br />GYPBRD - GYPSUM BOARD <br />HD -HEAD <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING <br />HT - HEIGHT <br />HB - HOSE BIB <br />HC - HANDICAP <br />INSUL - INSULATION <br />INT - INTERIOR <br />LVL - LAMINATED VENEER LUMBER <br />LT - LAUNDRY TUB <br />LGT - LIGHT <br />MAX - MAXIMUM <br />MATL - MATERIAL <br />MFR -MANUFACTURER <br />MECH - MECHANICAL <br />MTL - METAL <br />MC - MEDICINE CABINET <br />MIN - MINIMUM <br />MLDG - MOULDING <br />MNT - MOUNT OR MOUNTING <br />MO <br />- MASONRY OPENING <br />MUNT <br />- MUNTINS <br /># <br />-NUMBER <br />OC <br />- ON CENTER <br />OGD <br />- OVERHEAD GARAGE DOOR <br />OPNG <br />- OPENING <br />OPP <br />- OPPOSITE <br />OPT <br />- OPTIONAL <br />OH <br />- OVER HANG <br />OH CABS- <br />OVERHEAD CABS <br />PNT <br />- PAINT FINISH <br />PTD <br />- PAINTED <br />PED <br />-PEDESTAL <br />PERF <br />-PERFORATED <br />PLT <br />-PLATE <br />PLYWD <br />- PLYWOOD <br />PKT <br />-POCKET <br />LB <br />-POUND <br />PSF <br />- POUNDS PER SQUARE FOOT <br />PSI <br />- POUNDS PER SQUARE <br />PT <br />- PRESSURE TREATED <br />PB <br />- PUSH BUTTON <br />REF <br />- REFRIGERATOR <br />RECP <br />-RECEPTACLE <br />REINF <br />- REINFORCING <br />REQD <br />- REQUIRED <br />R/A <br />- RETURN AIR <br />RO <br />- ROUGH OPENING <br />RS <br />- ROUGH SAWN <br />SC <br />- SOLID CORE <br />SCP <br />-SCUPPER <br />SCRN <br />-SCREEN <br />SIM <br />- SIMILAR <br />SHLVS <br />-SHELVES <br />S/R <br />- SHELF & ROD <br />SH <br />- SINGLE HUNG WINDOW <br />SGD <br />- SLIDING GLASS DOOR <br />SPECS <br />- SPECIFICATIONS <br />SQ FT <br />- SQUARE FEET <br />SQ IN <br />- SQUARE INCH <br />STD <br />-STANDARD <br />STL <br />-STEEL <br />STRUCT <br />-STRUCTURAL <br />TEMP <br />-TEMPERED <br />THK <br />- THICK OR THICKNESS <br />TB <br />- TOWEL BAR <br />TOC <br />- TOP OF CONCRETE <br />TOM <br />- TOP OF MASONRY <br />TOP <br />- TOP OF PLATE <br />TP <br />- TOILET PAPER HOLDER <br />TYP <br />- TYPICAL <br />UNO <br />- UNLESS NOTED OTHERWISE <br />VAC <br />-VACUUM <br />VAL <br />-VALANCE <br />VERT <br />- VERTICAL <br />VIF <br />-VERIFY IN FIELD <br />VTR <br />- VENT THROUGH ROOF <br />V <br />-VOLT <br />WC <br />- WATER CLOSET <br />WH <br />- WATER HEATER <br />WL <br />- WIND LOAD <br />WP <br />- WEATHERPROOF <br />WWM <br />- WELDED WIRE MESH <br />W <br />- WIDE OR WIDTH <br />WDW <br />- WINDOW <br />W/ <br />- WITH <br />WD <br />- WOOD <br />I SYMBOL LEGEND: II <br />= <br />STAIR CALL OUT <br />HEIGHT OF <br />STEP DOWN <br />FOOTING CALL OUT - <br />STEP DOWN <br />0= <br />SEE FOOTING <br />TALLOWY <br />SCHEDULE <br />ARROW SHOWS <br />0 = <br />KEYNOTE CALL OUT <br />DIRECTION OF VIEW <br />1 A9 ELEV NUMBER <br />�q = <br />PRE -CAST LINTEL CALL <br />OUT - SEE LENTEL <br />SHEET NUMBER <br />EXTERIOR <br />SCHEDULE <br />ELEVATION MARKER <br />1 �--ELEV NUMBER <br />LG-2 <br />LEDGER CALL OUT - SEE <br />SHEET NUMBER <br />LEDGER SCHEDULE <br />4 A15 2 <br />�----ARROW SHOWS <br />3 DIRECTION OF VIEW <br />MULTI VIEW INTERIOR <br />ELEVATION MARKER <br />Al SHEET NUMBER <br />1 INT ELEV NUMBER <br />ARROW SHOWS <br />DIRECTION OF VIEW <br />INTERIOR ELEVATION <br />MARKER <br />ARROW SHOWS <br />DIRECTION OF CUT <br />1 <br />Al <br />SECTION NUMBER <br />SHEET NUMBER <br />LOCATION OF CUT <br />SECTION <br />MARKER <br />GENERAL NOTES <br />THE FOLLOWING TECHINCAL CODES SHALL APPLY: <br />2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, <br />ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 <br />2020 FBC PLUMBING RESIDENTIAL SECTION 604 <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />2. WATER -FLOW RATE. <br />PUBLIC FACILITIES LAV 0.5 G.P.M. <br />PRIVATE FACILITIES LAV 2.2 G.P.M. <br />SHOWER HEADS 2.5 G.P.M. <br />3. ALL PLUMBING WATER LINES <br />TO BE CPVC <br />VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO <br />JOBSITE CONDITIONS <br />THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC <br />RESIDENTIAL CODE <br />0 PORCHES AND BALCONIES <br />CHAP. 3 <br />0 HANDRAILS - CHAP. 3 <br />0 GUARDRAILS - CHAP. 3 <br />0 STAIRS - CHAP. 3 <br />CHIMNEY & FIREPLACE <br />CHAP. 10 <br />E] EGRESS WINDOWS <br />CHAP. 3 <br />5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS STATED <br />BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS AND O.H. <br />GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE ITEMS. THE <br />MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR SITE <br />INSTALLATION. <br />SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA AND <br />INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, OVERHEAD <br />GARAGE DOORS, AND ROOFING. <br />6. ALL DOORS INTERIOR & EXTERIOR ARE 6-8" UNLESS OTHERWISE NOTED ALL SHOWER <br />ENCLOSURES TO BE TEMPERED GLASS <br />7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF FLR <br />TO BE TEMPERED GLASS. (SECTION R308) <br />DIMENSIONING: <br />A. DIMENSIONS INDICATED ARE TO: <br />A.1. CMU WALL: OUTSIDE FACE OF WALL <br />A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />CORE -STUD <br />A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. <br />FURRING\ <br />A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL <br />CORE -STUD <br />A.4. WINDOW OPENINGS: <br />A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING <br />A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />A.5. DOOR OPENINGS: <br />A.5.1. CMU WALLS.- TO LEFT SIDE OF ROUGH OPENING <br />A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN <br />MEASURED FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR <br />FACE OF DOOR FRAME <br />A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO <br />CENTER OF DOOR <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES - AS INDICATED ON PLANS OR <br />FINISH SURFACE TO FINISH SURFACE <br />A.6.1. EXAMPLE: T-0" CLEAR INSIDE FINISH FOR ADA TRANSFER SHOWER <br />B. ALIGNMENT OF WALLS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, <br />TRUE AND PLUMB. <br />C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING <br />ORDER: <br />C.1. CODE MINIMUM - MAXIMUM DIMENSIONS AND CLEARANCES <br />C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS <br />C.3. FRAMED WALLS EXTERIOR <br />CA. FRAMED WALLS INTERIOR <br />C.5. DOORS AND WINDOWS <br />D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />UNLESS OTHERWISE NOTED <br />E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE <br />FACE OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF <br />THE STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS <br />AND COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING <br />THE DRAWINGS. <br />LE N NARni <br />LENNAR TAMPA DIVSION <br />4600 W CYPRESS ST, SUITE 200 <br />TAMPA, FL 33607 <br />313.574.5700 <br />1871 ATLANTA <br />VERSION CHANGES <br />VERSION <br />DESCRIPTION OF CHANGES <br />1.1 <br />CLIENT COMMENTS - ADDED LED LIGHT TO FOYER CEILING <br />2.0 <br />FLORIDA BUILDING CODE 6TH EDITION (2017) UPDATE <br />3.0 <br />ADDED OFF RIDGE VENT FOR ROOF VENTILATION <br />4.0 <br />PLAN REVISIONS <br />5.0 <br />PERMIT COMMENT REVISION <br />6.0 <br />TYPICAL TRUSS CONNECTOR REVISION <br />7.0 <br />FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATE <br />8.0 <br />ADDING K, L, M ELEVATIONS <br />INDEX OF DRAWINGS <br />SHT NO: <br />TITLE <br />CS <br />COVER SHEET <br />Al <br />FOUNDATION PLAN <br />A2 <br />iST AND 2ND FLOOR PLAN <br />A3 <br />DETAILS <br />A4 <br />2ND FLOOR - ROOF FRAMING PLAN <br />A5 <br />EXTERIOR ELEVATIONS & ROOF PLAN <br />A6 <br />1ST & 2ND FLOOR ELECTRICAL PLAN <br />A7 <br />INTERIOR ELEVATIONS <br />SNO <br />STRUCTURAL NOTES <br />SN1 <br />STRUCTURAL NOTES <br />S3M/S <br />FOUNDATION DETAILS <br />S4 <br />FRAME WALL DETAILS <br />S5 <br />ROOF FRAMING DETAILS <br />S6M/S <br />WALL SECTION DETAILS <br />SS <br />RETRO FIT DETAILS <br />ST <br />STAIR DETAILS <br />S11 <br />PRECAST DETAILS <br />S12 <br />PRECAST DETAILS <br />PA1.0 <br />PRODUCT APPROVAL INFO <br />PA1.1 <br />PRODUCT APPROVAL INFO <br />PA1.2 <br />PRODUCT APPROVAL INFO <br />PA1.3 <br />PRODUCT APPROVAL INFO <br />PA1.4 <br />PRODUCT APPROVAL INFO <br />SH 1.0 <br />HURRICANE SHUTTERS <br />SH 1.1 <br />HURRICANE SHUTTERS <br />SH 1.2 <br />HURRICANE SHUTTERS <br />SH 1.3 <br />HURRICANE SHUTTERS <br />SH 1.4 <br />HURRICANE SHUTTERS <br />SH 1.5 <br />HURRICANE SHUTTERS <br />WP1.0 <br />WATERPROOFING DETAILS <br />CIE,=►VAC? <br />DEC 151021 <br />DEC 15 zozz <br />OCT 2 8 222 <br />Virtual Review Assisi, Inc <br />Pima Review completedand apprpno <br />for cemPliauce with the 2020 FBC 216 Edirjitfi <br />by eebra Anne -; 2 d <br />NOTICE TO BUILDER & ALL SUBCONTRACTORS <br />IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE <br />BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL <br />CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE <br />INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND <br />APPROVAL BY THE DESIGN PROFESSIONAL. <br />N <br />N <br />O <br />i ". <br />N <br />T <br />ti <br />Lo <br />00 <br />Q <br />Lo <br />g <br />s y <br />ale ` <br />w <br />A <br />fez <br />O <br />m <br />fP <br />W <br />z <br />¢ <br />F <br />'oM <br />o <br />L <br />_W <br />i , <br />MN <br />v <br />5 <br />�u-0-0-2 <br />} <br />N <br />A� <br />E <br />t M <br />W <br />O <br />O �o <br />2 o <br />Q <br />— <br />•n�n,, <br />C• <br />��� <br />N <br />�< <br />W QN <br />C <br />V <br />L <br />E M <br />CP <br />7W <br />Oo <br />a <br />V <br />F <br />-0 <br />0 <br />LL! W Q <br />Q�W2~ <br />ZLLI J W~2 Y� Z <br />Vx1�"oo <br />Q< ¢aoZ�<<��Zo�oomZ�oZ <br />LLJ <br />F� rjW0��>L��az', L1OaQYWWo�oZ W�LL ¢¢ OOQ 0 O D�Qq�¢ <br />O <br />O <br />0w <br />"o O <br />O <br />Q t1 J . Lfl <br />�V7LL.d. <br />cl� Q (y <br />< U 00 <br />LU <br />z � I— <br />Z <br />W O <br />N <br />N <br />O <br />N <br />Co <br />N <br />O <br />0 <br />co <br />l I � � <br />m 00 Co 0 0 0 <br />O O O O O O O <br />O N N N N N N N <br />& O O O CV CM <br />NO6r <br />CV <br />N � rn rn - o cv <br />o T- o <br />o <br />0 0 0 0 o <br />0 <br />N0 o 0 0 0 0 0 <br />Lo >1 I C,i 1 ai I 'qr I Lri I to I ti <br />L <br />Cr z z <br />00 U) o <br />0 W cn <br />0 �wr— <br />o Q o�o <br />pa=2 <br />L z Zw~� <br />W� <br />r-Q F_moz <br />=o=z <br />C�z�J <br />Q ED <br />�ZZLL <br />w <br />N I� O_j2z <br />00 U�zU) <br />z ,—I ¢ o <br />Z U <br />U <br />O0 <br />W � <br />z z <br />W <br />C, S <br />W N <br />O LAST PLOT DATE <br />Jul. 15, 22 <br />z O COVER SHEET <br />a <br />