My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6381 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6381 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:11:35 PM
Creation date
2/19/2025 10:27:06 AM
Metadata
Fields
Template:
Building Plans
Street #
6381
Location
Ten Acre Ct
Contractor
Lennar
Building Plans - Permit #
5542
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONNECT <br />J <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A' <br />1/4 11= 1'-0" <br />SECOND FLOOR ELECTRICAL PLAN (ELEVATION A' <br />1 /411 = 1 '-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />OCT 28 <br />VRAi <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for Compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />co <br />SWITCH ° <br />4 1 /2" <br />DOORJAMB DUPLEX <br />OUTLET c� <br />TRIM---o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz_ <br />kS �' <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />6 STRUCTURED WIRE OUTLET <br />69 SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-p PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />�A3 CLG MNT LT FIXTURE <br />}B CLG MNT PREWIRE - FIXTURE BY OWNER <br />C SURFACE MNT FIXTURE <br />{T} WALL MNT FIXTURE <br />NOTE: <br />0 ND OPALEX - ALTERNATE <br />TUB/SHOWERCANS MAY BE <br />41 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />O APPROVED BY <br />O 50W MR16 4" LOW VOLTAGE OWNER <br />Q 50W PAR20 NFL 4" MINI ROUND RECESS <br />�01 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />O SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />-U-24- UNDER CABINET 24" <br />=S-24- SINGLE 24" FLUOR STRIP <br />=D-24- DOUBLE 24" FLUOR STRIP <br />U-36 - UNDER CABINET 36" <br />S-36 - SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />U&24zua 24" VANITY LIGHTING <br />36 :;-uP 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />® EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />® A/C REGISTER <br />a THERMOSTAT <br />IR SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />'0 OU <br />W <br />L r? <br />MN <br />cn <br />n <br />M <br />V -0 -0 � a <br />c'M <br />} O u o <br />�� <br />O (1)Q <br />�1 <br />U6� <br />_,_ <br />W <br />}4t <br />0 E <br />L .0) <br />N <br />W <br />LLJ Ur W <br />0 Ld ui W Q H <br />WF-a of W zW Z <br />Q�g��O3�WU-VOOW JO <br />W <br />Q Q <br />V <br />z(5x <br />Orn��aoZORgOmZz�< <br />W 0z20CI�a~ <br />Of <br />CY <br />U)LL <br />�QaOWYaZZLL0W <br />EL <br />0 Q <br />a~pw ��55 �W <br />OI o Z) azg <br />< <br />,tea <br />O <br />O <br />O <br />N <br />O LU <br />I --I <br />"0 O <br />0 �M <br />Q Ul) M LLn <br />awQI <br />��aM <br />a>-a00 <br />z <br />w � <br />W <br />J� <br />�O <br />N <br />N <br />O <br />N <br />1 <br />0 <br />1 <br />N <br />O <br />0 <br />W <br />CD V- <br />c- <br />O <br />� <br />O <br />� <br />O <br />N <br />O <br />NO <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />N <br />O <br />N <br />O <br />N <br />O <br />I <br />O� <br />N <br />I <br />C) <br />O <br />I <br />O <br />6 <br />I <br />O <br />I <br />O <br />OO <br />I <br />N <br />I <br />M <br />N <br />Cr-I <br />0 <br />0 <br />6 <br />0 <br />OI <br />0 <br />O <br />N <br />(D <br />0 <br />0 <br />0) <br />` <br />N� <br />> <br />� <br />O <br />N <br />CD <br />Cl) <br />� <br />CD <br />LIDCO <br />O <br />O <br />N <br />L <br />M <br />(� <br />Z Z <br />—ZO <br />vV <br />WU~> <br />0WC0 <br />O <br />c,o�� <br />~�� <br />Q <br />^ <br />i1 <br />W <br />z <br />ZWP <br />~mOZ <br />= Z <br />!=n <br />V <br />0Lz <br />j J <br />Z <br />Q <br />Z <br />ri <br />�Zz <br />M W <br />N <br />W � <br />O <br />-�z <br />Q00UWZz <br />z <br />�QO <br />z <br />U <br />U <br />� <br />00 <br />W <br />� <br />Z <br />a <br />Z <br />z <br />w <br />J <br />W <br />C- <br />o <br />O <br />LAST PLOT DATE <br />Jul. 15, 22 <br />z <br />0 <br />1ST & 2ND FLOOR <br />J <br />ELECTRICAL PLAN A <br />_-7—..:._ —F I II 1 -11 ----T—.I f <br />o� M <br />
The URL can be used to link to this page
Your browser does not support the video tag.