6794 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6794 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:49:40 AM
Creation date
2/19/2025 10:28:03 AM
Metadata
Fields
Template:
Building Plans
Street #
6794
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
5970
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
42" KNEE WALL WITH �\ <br />1x8 CAP & CASING OR <br />36" RAILING _- <br />36" H. CONT. <br />GRASPABLE <br />RAILING <br />3/4" PLYWOOD <br />DECKING <br />- <br />- - - - - -16 -- <br />15 <br />1 3. <br />PRE-ENG FLOOR <br />TRUSS <br />q12 <br />ix TREAD <br />1 8 <br />2x4 THRUST <br />1x RISERS (TYP.) f 1, , 7 <br />0° <br />BLOCK <br />00 <br />= F- 6 <br />X <br />(3) 2x12 <br />5 <br />STRINGERS t` 42" KNEE WALL WITH ( <br />1x8 CAP & CASING OR 4 <br />3/4" PLYWOOD 36" RAILING 3 <br />- <br />DECKING <br />ih <br />2x6 LANDING 2x4 THRUST 2 <br />BLOCK ' 1 <br />2x4 FRAMING <br />TYP. STAIR SECTION <br />SCALE: 1/4" = V-0" <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 314" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSI <br />stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />;iiser height: <br />'he riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />djacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />'read depth: <br />'he tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />1e foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />ight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Vinders: <br />Vinder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />rojection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />(ches at any point within the clear width of the stair. <br />'he radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />lore than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />mallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />eveling of nosings shall not exceed 1/2 inch. <br />landrails: <br />andrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />eight measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />ian 34 inches and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a <br />oint directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />turned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />1/2 inches between the wall and the handrails. <br />'rip -size: <br />andrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater than 2 inches <br />r provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />uards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />ches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />equired guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />ches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />cads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />)here 4 inches in diameter. <br />nder-stair protection: <br />iclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />ith 1/2-inch gypsum board. <br />SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM 0 <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENC <br />LANDING FOf <br />STRINGERS - <br />CONNECT TC <br />M <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1 /4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO._ <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />3/4" PLYWOOD <br />DECKING <br />-2x6 LANDING <br />2x4 FRAMING <br />CONT. HANDRAIL <br />RETURN TO <br />WALL DETAIL <br />B SCALE: DETAIL <br />25-0" <br />74" 16-1 " 6-7 <br />2x4 #2 SPF STUDS @ 16" 1 <br />O.C. TYP. @ 2nd FLOOR H1 Op H1 D2 <br />EXTERIOR WALLS B <br />TYP <br />1/2 33 SH @ <br />6 (2) 25-SH CORNERS <br />D2 TEMP D2 EGRESS <br />o 4-SH fn <br />_ I - <br />J RB P I 1 " " 1668 N <br />w= SPECS. 1 _ B F <br />C7 - 4'-4" co 5'-6' - - 2 4 0 <br />I <br />a (V J I I- = --- r M <br />W Z Z o O BATH ^ 24 -- 3 <br />D2 <br />I- O Y p I I 8' 0" FLAT CLG TILE RlSHIM. w/ (1) <br />--- o G.T.G. <br />"-_ - - - --------` MSTAM36 <br />48x42 @ BASE <br />3 RECESS" I <br />B - <br />SHOWERiD2 T-0" f-- 2 - L 12'-10" <br />SIM. w/ 1 1 - I 36" x 22" <br />O TI E TO, <br />MSTAM36 I I ATTIC <br />@ BASE - -- ---- Ls ACCESS <br />__ <br />NF1OWNER'S <br />00 <br />cv iv T CLG SUITE <br />O M I C RPET <br />TP 2468 8'-0" FLAT CLG <br />-- --- CARPET <br />in <br />N <br />N <br />4068 <br />10 <br />B.F. <br />c _ co BEDROOM 2 N - - - - - <br />R/SH <br />8'-0" FLAT CLG <br />CARPET <br />U) 12'-2" 4'-8" 4" T-6" <br />o D2 N 0 - T <br />LU <br />io ih <br />10 rn <br />H1 A <br />5068 2668 42" H 1/2 WALL 116 <br />B.F. OR RAILING PER <br />SPECS 1115 <br />J ----- - I 14 <br />S6---------- 1 13 <br />TYP. @ 2 R/SH U `� N D2 <br />STORY. SEE - 1 <br />o� I 12 <br />JJlS6 FOR o o TECH 11 0 H1 <br />STEMWALL „ CENTER I <br />OPT. - -- I 10 <br />3'-3" 0 5'-7" 3'-4" 5'-8" 3'-3" 1 9 T-11" <br />A.F.F. �`S 8 1 <br />A H s -1 1 L1 <br />ILE TO 8' 0" FLAT C 1,_ - <br />TILE _ - _ J 7 <br />2868 <br />_ 11 3 <br />N m D2 <br />N I 2 3 4 51 SIM. w/ (1) <br />�64> MSTAM36 <br />3 ti @ BASE <br />DZ BEDROOM 3 4-SH N T <br />SIM. w/ 1 8'-0" FLAT CLG a, <br />CARPET G.T. <br />MSTAM36 __-- -_-_-- I _ _-_-_-_-- <br />@ BASE -I_ --T I <br />- <br />1 V-6" 2'-4" 11'-2" <br />I G.T. <br />80 <br />MSTAM36 C7 a l v m <br />@BASE BEDROOM 4 3 <br />3 I 8'-0" FLAT CLG D2 <br />D2 CARPET <br />G.T. SIM. w/ (1) <br />MSTAM36 <br />00 <br />I rn @ BASE <br />1/2 33 SH m I <br />I (�DD92 <br />I <br />25-SH 25-SH <br />I � EGRESS � EGRES <br />I D2 <br />I <br />- - - - - - - - - - - <br />2'-10" Z-10" 2'-11" 13'-6" 2'-11" <br />5-8" 19'4" <br />I 25-0" <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I------------------------------------ --I <br />REVISION NOTES 12/17/2009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />TO BE PANNED WITH A PRE-FAB. BASE. <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />RECESS. REFER TO MASON'S SCOPE FOR <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />40' PRODUCT LINE - MIN. 48" x 64" <br />50' PRODUCT LINE - MIN. 48" x 76" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W1 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 314" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />*VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />+29.7 / -32.2 <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />G� <br />SEE SIN SHEET O SEE SIN SHEET <br />140 MPH amm <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />182'X25' <br />S.H. <br />13 <br />20X38' <br />182X373 <br />S.H. <br />14 <br />20X50g <br />182X50 <br />S.H. <br />15 <br />20X63 <br />18zX62 <br />S.H. <br />16 <br />20X72 <br />1812X71 <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />1 H3 <br />27 1/4 X 38 a <br />26 x 37 a <br />S.H. <br />1 H4 <br />27 4 X 50 g <br />26 x 50 <br />S.H. <br />1H5 <br />274X63 <br />26X621/2 <br />S.H. <br />1H6 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 z X 25 1/2 <br />S.H. <br />23 <br />37 Ja X 38 a <br />36 1 X 37 3/4 <br />S.H. <br />24 <br />37 a X 50 a <br />36' X 50 <br />S.H. <br />25 <br />37 4 X 63 <br />36 ' X 62 1/2 <br />S.H. <br />26 <br />37 a X 72 <br />36 z X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 � WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 � X 251 <br />S.H. <br />33 <br />54 X 38 3 <br />52' X 37' <br />S.H. <br />34 <br />54 X 50' <br />52 ' X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 2 X 62 2 <br />S.H. <br />36 <br />54 X 72 <br />52 2'X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R3.02.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its !largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'4' A.F.F. I <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA 2073 S.F. <br />GARAGE 396 S.F. <br />LANAI 104 S.F. <br />ENTRY 32 S. F. <br />TOTAL SQ. FT. 2605 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN-B <br />SCALE: )/4"=V-0" <br />r <br />!V <br />cm <br />C,J <br />-® <br />r- o <br />m <br />c� <br />c v N <br />mx <br />N R O a- <br />y N O N <br />Y a� <br />3 <br />,- <br />� <br />a <br />o. .a <br />0 <br />S -*� <br />a <br />UJ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />ON <br />W <br />AN Amb, 4 <br />0v E <br />0 8 <br />(,y <br />O00 <br />G <br />N <br />:3 C? <br />cnrZr,II <br />q to <br />N O <br />C <br />Q <br />J LL o- <br />-J LL a <br />Z <br />J <br />m Lu <br />= °' a <br />W <br />zoos <br />� o <br />W <br />o' <br />W rn rn m W <br />Z <br />L0 N Z Q <br />ZN <br />O U <br />v t7 <br />W <br />❑o <br />V M r <br />Z N M <br />z � <br />Z n <br />Q <br />J <br />a <br />� <br />z <br />c <br />CU <br />o <br />a--+ <br />� <br />0 V <br />O <br />W g <br />'A'w <br />�to <br />� <br />v <br />w <br />i <br />L N <br />v o N <br />Q <br />• <br />N <br />(III <br />c) <br />M <br />u- <br />o ' <br />w <br />z <br />Z <br />Q <br />I <br />m <br />z p <br />t= U <br />�o <br />oLL <br />z <br />¢� <br />zp <br />o a <br />(U <br />¢ <br />w fY <br />U <br />O E <br />O <br />&� <br />� <br />o <br />wo <br />z <br />co <br />`z <br />mo <br />J <br />$� <br />¢z <br />Z z <br />g o <br />W <br />U> <br />w <br /><o <br />a <br />m <br />=� <br />v <br />ola <br />a= <br />o 3 <br />,o C <br />: <br />e <br />M <br />� <br />O <br />CID Lr) <br />O <br />CV <br />o <br />LO <br />Cr Y <br />O <br />(n m <br />> <br />CV <br />0 <br />LO <br />�.. <br />O <br />LL <br />cf <br />O <br />C <br />m <br />o <br />Lin <br />CN <br />E <br />c <br />�' <br />Z <br />(6 <br />Z <br />E O <br />N T <br />tp <br />U <br />a <br />Q 0 <br />� <br />JOB <br />NO : <br />23-00510 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />I IIiILIi. 1t; <br />