Laserfiche WebLink
a <br />d <br />O <br />N <br />1 <br />M <br />U <br />BUILDING AREA CALCULATION: TYPE I, No. 3,4 & 5 <br />OCCUPANCY TYPE: SINGLE OCCUPANCY MULTISTORY BUILDING (GROUP R-2 OCCUPANCY) <br />CONSTRUCTION TYPE: V A <br />FIRE SPRINKLER PROVIDED: NFPA 13R SYSTEM PER FBC-B 903.3.1.2. <br />BUILDING AREA AND HEIGHT LIMITATION <br />ALLOWED PROPOSED <br />BUILDING HEIGHT (FBC-B 504.3) 69-0" 50'-10" <br />MAX NUMBER OF STORIES (FBC-B 504.4) 4 4 <br />MAXIMUM AREA FOR A SINGLE STORY (FBC-B 506.2) Per Calculation. 18,480 SF 15,337 SF <br />MAXIMUM BUILDING AREA (FBC-B 506.2) Per Calculation. 73,920 SF 60,754 SF <br />FRONTAGE INCREASE CALCULATION <br />AREA FACTOR INCREASE DUE TO FRONTAGE PER FBC-B 506.3.3 ARE SHOWN FOR EACH BUILDING <br />ON SITE. EQUATION 5-5 If = [F/P - 0.25]W/30 (IF FRONTAGE INCREASE IS NOT NEEDED If=0) <br />BUILDING # FRONTAGE INCREASE VALUE OF "W" PER EQUATION 5-4 <br />W = 30 If = [602.6/762 - 0,25] 30/30 W = (Lf x wt + L2 x w2 + L3 x w3....)/F <br />F = 602.6 If = [0.79-0.25] 1 W = (225x30 + 76.3x30 + 22540 + 76.340Y602.6 <br />P =762' If = 0.54 W = 30 <br />ALLOWABLE AREA DETERMINATION <br />ALLOWABLE AREA DETERMINATION CALCULATIONS PER FBC-B 506.2 <br />SINGLE -OCCUPANCY, MULTISTORY BUILDINGS (FBC-B 506.2.3) <br />EQUATION 5-2 Aa = [At + (NS X If)] x Sa <br />ALLOWED AREA FOR SINGLE STORY: Aa = [12,000 sf + (12,000 X 0.54)] x 1=18,480 SF <br />ALLOWED AREA OF THE TOTAL BUILDING: A8 = [12,000 sf + (12,000 X 0.54)] x 4=73,920 SF <br />BUILDING AREA CALCULATION: TYPE II, No. 1 & 2 <br />OCCUPANCY TYPE: SINGLE OCCUPANCY MULTISTORY BUILDING (GROUP R-2 OCCUPANCY) <br />CONSTRUCTION TYPE: V-A <br />FIRE SPRINKLER PROVIDED: NFPA 13R SYSTEM PER FBC-B 903.3.1.2. <br />BUILDING AREA AND HEIGHT LIMITATION <br />ALLOWED PROPOSED <br />BUILDING HEIGHT (FBC-B 504.3) 60'-0" 51'-0" <br />MAX NUMBER OF STORIES (FBC-B 504.4) 4 4 <br />MAXIMUM AREA FOR A SINGLE STORY (FBC-B 506.2) Per Calculation. 19,080 SF 14,293 SF <br />MAXIMUM BUILDING AREA (FBC-B 506.2) Per Calculation. 76,320 SF 56,578 SF <br />FRONTAGE INCREASE CALCULATION <br />AREA FACTOR INCREASE DUE TO FRONTAGE PER FBC-B 506.3.3 ARE SHOWN FOR EACH BUILDING <br />ON SITE. EQUATION 5-5 If = [F/P - 0.25]W/30 (IF FRONTAGE INCREASE IS NOT NEEDED If=0) <br />BUILDING # FRONTAGE INCREASE VALUE OF "W" PER EQUATION 5-4 <br />W = 30 If = [577.2/688 - 0.25] 30/30 W = (Lf x wt + L2 x w2 + L3 x w3....)/F <br />F = 577.2 If = [0.84-0.25] 1 W = (212.3x30 + 76.340 + 212.3x30 + 76.340u577.2 <br />P =688' If = 0.59 W = 30 <br />ALLOWABLE AREA DETERMINATION <br />ALLOWABLE AREA DETERMINATION CALCULATIONS PER FBC-B 506.2 <br />SINGLE -OCCUPANCY, MULTISTORY BUILDINGS (FBC-B 506.2.3) <br />EQUATION 5-2 Aa = [At + (NS X If)] x Sa <br />ALLOWED AREA FOR SINGLE STORY: As = [12,000 sf + (12,000 X 0.59)] x 1=19,080 SF <br />ALLOWED AREA OF THE TOTAL BUILDING: Aa = [12,000 sf + (12,000 X 0.59)] x 4 = 76,320 SF <br />BUILDING AREA CALCULATION: CLUB HOUSE <br />OCCUPANCY TYPE: SINGLE OCCUPANCY (GROUP A-3) <br />CONSTRUCTION TYPE: V-A <br />FIRE SPRINKLER PROVIDED: NOWSPRINKLERED <br />BUILDING AREA AND HEIGHT LIMITATION <br />HEIGHT LIMITATION PER OCCUPANCY (FBC-B 504.3) ALLOWED PROPOSED <br />GROUP A-3: 50'-0" 22'-0" <br />MAX NUMBER OF STORIES (FBC-B 504.4) <br />GROUP A-3: 2 1 <br />MAX BUILDING AREA (FBC-B 506.2.1) Per Calculation. 14,375 SF 9,087 SF <br />FRONTAGE INCREASE CALCULATION <br />AREA FACTOR INCREASE DUE TO FRONTAGE PER FBC-B 506.3.3 ARE SHOWN FOR EACH BUILDING <br />ON SITE. EQUATION 5-5 If = [F/P - 0.25]W/30 (IF FRONTAGE INCREASE IS NOT NEEDED If=O) <br />BUILDING # FRONTAGE INCREASE VALUE OF "W" PER EQUATION 5-4 <br />W = 30 If = [283.9/564 - 0.25] 30/30 W = N x wt + L2 x w2 + L3 x w3....}/F <br />F = 283.9 If = [0.50-0.25] 1 W = (69.3x30 + 131.3x30 + 83.3x30u283.9 <br />P =564' If = 0.25 W = 30 <br />ALLOWABLE AREA DETERMINATION <br />SINGLE -OCCUPANCY, SINGLE STORY BUILDINGS (FBC-B 506.2.1) <br />EQUATION 5-1 Aa = [At + (NS X If)] <br />MAXIMUM BLDG AREA ALLOWED: Aa = [11,500 sf + (11,500 sf X 0.25)]=14,375 SF <br />Vicinity Ma <br />0 <br />M <br />Q <br />C� <br />co <br />i <br />NTS <br />SHEET NOTES <br />A REFER TO SHEET A1.03 FOR GENERAL NOTES <br />B THIS SHEET IS FOR REFERENCE AND IS INTENDED ONLY TO CONVEY <br />GENERAL BUILDING DATA AND APPROXIMATE LAYOUT, REFER TO CIVIL <br />DRAWINGS FOR ALL PROPERTY BOUNDARY / EASEMENT / SETBACK <br />INFORMATION, SIDEWALK LOCATIONS, PARKING COUNTS, ACCESSIBLE <br />PARKING AND SITE ACCESSIBLE ROUTE, RETAINING WALLS, GRADING, <br />UTILITY CONNECTIONS, BUILDING LOCATIONS, FINISHED FLOOR <br />ELEVATION FOR EACH BUILDING, AND OTHER ITEMS OUTSIDE THE <br />BUILDING FOOTPRINT <br />C CONTRACTOR SHALL VERIFY ALL CONDENSER PAD LOCATIONS WITH <br />SITE CONDITION, MAINTAIN THE FOLLOWING:18" MIN FROM BLANK WALL, <br />36" MIN FROM FACE OF ELECTRICAL PANEL, AND 36" MIN FROM WINDOW / <br />BALCONY <br />D REFER TO LANDSCAPE DRAWINGS FOR PLANTING, IRRIGATION, <br />HARDSCAPE ELEMENTS, AND LANDSCAPE ACCENT LIGHTING <br />0 LEGEND <br />BUILDING LETTER <br />X NO. OF UNITS <br />Y Z <br />BUILDING TYPE, UNO* <br />SITE LOCATION <br />RESIDENTIAL R2 OCCUPANCY <br />ASSEMBLY A3 OCCUPANCY <br />PERIMETER OF THE BLDG FACING OPEN SPACE <br />2 <br />M <br />FO UME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AR97193 <br />www.forumarchitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />02/17/2022 <br />Karen V McIntyre <br />Aonn4-7n4 Q <br />SET DISTRIBUTIONS: <br />11/24/21 100% DD Set <br />12/23/21 Owner Review Set <br />02/17/22 Permit Set <br />I <br />I <br />0 SHEET REVISIONS: <br />PROJECT NO. 4097 <br />Apartments - <br />Architectural Site Plan <br />Architectural Site Plan <br />60' 30' 0 60' 120' <br />1 If <br />= 60'-0" <br />A2.01 <br />