<br />REFERENCED DA TA
<br />1. TOPOGRAPHIC SURVEY WAS OBTAINED FROM MAURICE W. BELL, PROFESSIONAL LAND SURVEYOR , AND PERFORMED BY
<br />MAURICE W. BELL, DATED 05-22-2020.
<br />2. SUBSURFACE UTILITY EXPLORATION WAS OBTAINED FROM AND PERFORMED DATED
<br />3. ALL ELEVATIONS ARE REFERENCED TO - , THE HORIZONTAL DATUM IS BASED ON GPS OBSERVATIONS TAKEN FROM THE
<br />NATIONAL GEODETIC SURVEY CONTROL STATION S37-152. FLORIDA STATE PLANE GRID SYSTEM - WEST ZONE.
<br />4. THE SURVEY INFORMATION CONTAINED HEREIN WAS OBTAINED FOR DESIGN PURPOSES AND MAY NOT BE AN ADEQUATE
<br />REPRESENTATION OF ACTUAL CONDITIONS FOR PROJECT CONSTRUCTION. EXISTING CONTOURS SHOWN REPRESENT
<br />INTERPOLATIONS/EXTRAPOLATIONS FROM THE BEST AVAILABLE SURVEY DATA. ALL RISKS RESULTING FROM THE USE OR
<br />INTERPRETATION OF THE SURVEY DATA SHOWN SHALL BE BORNE BY THE CONTRACTOR.
<br />5. GEOTECHNICAL INVESTIGATION AND RECOMMENDATIONS PERFORMED BY __ , REFER TO REPORT DATED
<br />6. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ESTABLISH IN THE FIELD LIMITS OF CONSTRUCTION, BENCHMARKS (ELEV.),
<br />COORDINATES, CENTER LINES, AND STATIONING AS REQUIRED TO CONSTRUCT THIS PROJECT.
<br />GENERAL
<br />7. ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE MINIMUM STANDARDS SET FORTH BY THE FDEP, AWWA, NSF, AND
<br />CITY OF ZEPHYRHILLS.
<br />8. THE CONTRACTOR IS ADVISED NOT TO SCALE FROM DRAWINGS BUT TO FIELD VERIFY ALL DIMENSIONS. THE DIMENSIONS OF
<br />SPECIFIED AND FURNISHED PRODUCTS AND MATERIALS TAKE PRECEDENCE OVER DIMENSIONS INDICATED ON THE DRAWINGS. IF
<br />SIGNIFICANT DEVIATIONS OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AT LEAST 72 HOURS PRIOR TO
<br />CONSTRUCTION FOR A DETERMINATION AND RESOLUTION.
<br />9. THE CONTRACTOR SHALL CHECK PLANS FOR CONFLICTS AND DISCREPANCIES PRIOR TO PERFORMING ANY WORK IN THE
<br />AFFECTED AREA.
<br />10. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BECOME FAMILIAR WITH THE PERMIT AND INSPECTION REQUIREMENTS SPECIFIED
<br />BY THE VARIOUS GOVERNMENTAL AGENCIES AND THE ENGINEER. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS
<br />PRIOR TO CONSTRUCTION AND SCHEDULE INSPECTION ACCORDING TO AGENCY INSTRUCTIONS.
<br />11. ALL WORK PERFORMED SHALL COMPLY WITH THE REGULATIONS AND ORDINANCES OF THE VARIOUS GOVERNMENTAL AGENCIES
<br />HAVING JURISDICTION OVER THE WORK, CONSTRUCTION LAYOUT/LIMITS OF CONSTRUCTION.
<br />12. THE CONTRACTOR SHALL OBTAIN THE SERVICES OF A PROFESSIONAL LAND SURVEYOR LICENSED IN THE STATE OF FLORIDA
<br />FOR LAYOUT. PROOF OF LICENSE SHALL BE SUBMITTED TO THE ENGINEER BEFORE BEGINNING LAYOUT.
<br />13. NO DISTURBANCE SHALL BE ALLOWED OUTSIDE OF THE RIGHT OF WAYS AND/OR THE LIMITS OF CONSTRUCTION SHOWN ON
<br />THE DRAWINGS UNLESS APPROVED BY THE OWNER OR SPECIFICALLY NOTED ON THE DRAWINGS.
<br />14. EXISTING CONDITIONS LOCATIONS, ELEVATIONS, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES, AND OTHER FEATURES
<br />ARE SHOWN BASED ON THE BEST INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. CONTRACTOR
<br />SHALL VERIFY THE LOCATIONS, ELEVATIONS, AND DIMENSIONS OF ALL EXISTING UTILITIES, STRUCTURES, AND OTHER
<br />FEATURES AFFECTING THIS WORK PRIOR TO CONSTRUCTION.
<br />15. PRIOR TO SHOP DRAWING PREPARATION AND SUBMITTAL AND PURCHASE OF RELATED MATERIALS, THE CONTRACTOR SHALL
<br />FIELD VERIFY EXISTING UTILITIES (LOCATION, SIZE, MATERIALS OF CONSTRUCTION, OUTSIDE DIAMETER, WALL THICKNESS,
<br />ROUNDNESS, ELEVATIONS, ETC.) TO WHICH CONNECTION(S) WILL BE MADE. CONTRACTOR SHALL INCLUDE FIELD
<br />MEASUREMENTS ON SHOP DRAWINGS,
<br />16. THE CONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER IN WRITING IMMEDIATELY IF CONFLICTS BETWEEN THE DRAWINGS
<br />AND ACTUAL CONDITIONS ARE DISCOVERED. THE CONTRACTOR SHALL ACCURATELY RECORD ANY SUCH CONFLICTS ON THE
<br />RECORD DRAWINGS.
<br />17. ANY PROPERTY CORNERS MONUMENTS, R BENCH MARK WITHIN THE PROJECT AREA SHALL PROTECTED UNLESS
<br />E 0 BE C S E LL BE
<br />OTHERWISE INDICATED FOR DEMOLITION. IF ANY SUCH ITEMS ARE IN DANGER OF DAMAGE OR HAVE BEEN DAMAGED, THE
<br />CONTRACTOR SHALL NOTIFY THE OWNER AND THE ENGINEER IMMEDIATELY AND REPLACE/RESTORE THESE ITEMS AT NO
<br />ADDITIONAL COST TO THE OWNER. IF OWNER CHOOSES TO SELF PERFORM THE WORK OR INCURS RELATED EXPENSES, THE
<br />CONTRACTOR SHALL REIMBURSE THE OWNER FOR ALL COSTS ASSOCIATED WITH THE EFFORT.
<br />18. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING FACILITIES, ABOVE OR BELOW GROUND THAT
<br />MAY OCCUR AS A RESULT OF THE WORK PERFORMED BY THE CONTRACTOR CALLED FOR IN THIS CONTRACT.
<br />UTILITY COORDINATION
<br />19. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES NEAR THE PROJECT AREA AT LEAST 48 HOURS PRIOR TO CONSTRUCTION.
<br />THIS SHALL INCLUDE NOTIFYING "SUNSHINE STATE ONE CALL OF FLORIDA" AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION
<br />WORK TO HAVE ALL EXISTING UTILITIES LOCATED. THE PHONE NUMBER IS 1-800-432-4770 AND THE WEB SITE IS
<br />WWW.CALLSUNSHINE.COM. IN INSTANCES WHERE DIGGING OCCURS IN WETLANDS, THE NOTIFICATION PERIOD SHALL BE
<br />INCREASED FROM AT LEAST 48 HOURS TO AT LEAST 10 DAYS.
<br />20. FLORIDA LAW (FS 553.851) REQUIRES THAT PERSONS MAKING EXCAVATIONS IN PUBLIC STREETS, ALLEYS, RIGHT-OF-WAYS
<br />OR UTILITY EASEMENTS MUST FIRST OBTAIN INFORMATION ON LOCATIONS OF UNDERGROUND GAS PIPELINES.
<br />21. THE CONTRACTOR IS RESPONSIBLE FOR BRACING, SHORING, OR PROVIDING OTHER MEANS NECESSARY TO PROTECT AND
<br />SUPPORT EXISTING UTILITIES, STRUCTURES, AND OTHER FEATURES (EXPOSED OR UNEXPOSED) THAT MAY BE IMPACTED BY
<br />HIS WORK.
<br />22. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING POWER/TELEPHONE COMPANIES AND ARRANGING TO HAVE
<br />UTILITIES POLES HELD AND/OR GUY WIRES REMOVED AND REPLACED, IF NECESSARY FOR CONSTRUCTION, AT NO ADDITIONAL
<br />COST TO THE OWNER.
<br />23. THE CONTRACTOR SHALL NOTIFY THE APPROPRIATE PUBLIC AGENCY(IES) PRIOR TO COMMENCING WORK WITHIN THEIR
<br />JURISDICTION.
<br />CONSTRUCTION SAFETY
<br />24. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BE FAMILIAR WITH THE OSHA EXCAVATION SAFETY STANDARDS AND TO
<br />ABIDE BY THEM AS COVERED UNDER THE FLORIDA TRENCH SAFETY ACT.
<br />25. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION SAFETY.
<br />RESTORATION
<br />26. ALL PAVING, STABILIZED EARTH, DRIVEWAYS, CURBS, SIDEWALKS, FENCES, SOD, LANDSCAPING, CULVERTS, ETC. DISTURBED BY
<br />CONSTRUCTION ACTIVITIES SHALL BE RESTORED BY AND AT THE EXPENSE OF THE CONTRACTOR TO THE SATISFACTION OF
<br />THE OWNER.
<br />27. ALL EXISTING SIGNS AND MAILBOXES LOCATED WITHIN THE PROJECT SHALL BE REMOVED AND REINSTALLED OR REPLACED AS
<br />REQUIRED DURING CONSTRUCTION., AND SHALL BE RESTORED BY AND AT THE EXPENSE OF THE CONTRACTOR TO THE
<br />SATISFACTION OF THE OWNER.
<br />28. ALL SIDEWALKS DAMAGED DURING CONSTRUCTION ARE TO BE A MINIMUM WIDTH OF 5', A MINIMUM OF 4" THICK, 3,000 PSI
<br />CONCRETE, AND SHALL BE REINFORCED WITH 1.4X1.4 W.W.M., ALL IN CONFORMANCE WITH MACDILL DESIGN GUIDELINES,
<br />LATEST EDITION.
<br />ACCESS/MAINTENANCE OF FACILITIES
<br />29. THE CONTRACTOR SHALL PROVIDE ACCESS TO ALL EXISTING UTILITIES/FACILITIES AND MAINTAIN UNINTERRUPTED SERVICES
<br />THROUGHOUT THE CONTRACT PERIOD.
<br />PIPING NOTES
<br />30. LAY PIPE TO UNIFORM GRADE BETWEEN INDICATED ELEVATION POINTS. CONTRACTOR SHALL TAKE CARE TO PROVIDE PROPER
<br />GRADE ELEVATIONS AND ALIGNMENTS.
<br />31. SIZE OF FITTINGS SHOWN ON PLANS SHALL CORRESPOND TO THE ADJACENT STRAIGHT RUN OF PIPE UNLESS NOTED
<br />OTHERWISE. TYPE OF JOINT AND FITTING MATERIALS SHALL BE AS SPECIFIED FOR THE ADJACENT STRAIGHT RUN OF PIPE
<br />UNLESS NOTED OTHERWISE.
<br />32. ALL PIPE LENGTHS ARE APPROXIMATE. PIPE MEASUREMENTS FOR STRAIGHT ENDWALL END SECTIONS ARE TO END OF PIPE.
<br />33. PIPE HANGERS AND SUPPORTS ARE NOT SHOWN UNLESS A SPECIAL TYPE OR CONFIGURATION IS REQUIRED. FINAL SUPPORTS,
<br />LOCATIONS, AND TYPES SHALL BE DETERMINED BY THE CONTRACTOR AND INCLUDED IN THE PIPELINE DRAWING SUBMITTALS
<br />FOR REVIEW AND APPROVAL BY THE ENGINEER PRIOR TO INSTALLATION. MAXIMUM SPACING SHALL BE AS SPECIFIED.
<br />ll A =
<br />34. ALL WATER PIPES ARE TO BE CONSTRUCTED WITH 36" MINIMUM COVER UNLESS OTHERWISE NOTED ON THE PLANS. ALL
<br />WATER MAINS ARE DR-18 PVC UNLESS OTHERWISE NOTED.
<br />35. FURNISH AND INSTALL 10 GAUGE TRACER WIRE ON ALL MAIN PIPELINES. WIRE TO EXTEND INTO EACH VALVE BOX WITH
<br />SUFFICIENT EXCESS TO BRING WIRE THREE FEET ABOVE FINISH GRADE.
<br />36. WATER SYSTEMS R T T MINIMUM F 1 - E S ARE TESTED 0 A N MUM 0 50 PSI FOR TWO-HOUR DURATION AS PER AWWA C 600 STANDARDS.
<br />37. ALL FIRE FLOW LINES WILL RUN SEPARATE FROM THE DOMESTIC WATER MAINS AND HAVE A FIRE DETECTION METER AND A
<br />FIRE LINE BACK FLOW PREVENTION ASSEMBLY (BFP). ASSEMBLY SHALL INCLUDE A LOW FLOW BY-PASS METER W/ RPZ.
<br />38. ALL POTABLE WATER CONNECTIONS SHALL BE MADE WITH CUTTING -IN TEES WITH VALVES. ANY EXCEPTIONS TO THIS WILL
<br />REQUIRE CITY OF ZEPHYRHILLS APPROVAL. WHEN ALLOWED BY CITY OF ZEPHYRHILLS, HOT TAP ("WET TAP") CONNECTIONS
<br />SHALL BE PERFORMED BY A LICENSED, UNDERGROUND CONTRACTOR, WITH ADVANCE NOTIFICATION (72 HOURS) TO THE CITY
<br />OF ZEPHYRHILLS INSPECTOR.
<br />39. WATER TAPPING SADDLES SHALL BE DOUBLE STRAP BRASS OR DUCTILE IRON OR EPDXY COATED STEEL WITH STAINLESS
<br />STEEL HARDWARE. TIE STRAPS AND BOLTS SHALL BE CORROSION RESISTANT ALLOY STEEL. FULL CIRCLE STAINLESS STEEL
<br />TAPPING SADDLE SLEEVE WITH RESILIENT SEATED TAPPING VALVE SHALL BE USED FOR PROPOSED WATER AND FORCE MAIN
<br />CONNECTIONS.
<br />40. ALL FIRE HYDRANTS SHALL BE PAINTED IN ACCORDANCE WITH AGRAM 07-07 (MAY 2007). CAPS SHALL BE PAINTED WITH
<br />REFLECTIVE -TYPE PAINT.
<br />BARREL COLOR DISTRIBUTION SYSTEM TYPE
<br />YELLOW PUBLIC (POTABLE)
<br />RED FIRE PROTECTION (POTABLE WITH BFP)
<br />PURPLE RECLAIMED (NON -POTABLE)
<br />CAPS RATED CAPACITY (AT 20PSI RESIDUAL PRESSURE)
<br />LIGHT BLUE 1500 GPM
<br />GREEN 1000-1499 GPM
<br />ORANGE 500-999 GPM
<br />RED <500 GPM
<br />SEWER
<br />41. ALL WASTEWATER FORCE MAINS ARE TO BE CONSTRUCTED WITH 48" MINIMUM COVER UNLESS OTHERWISE NOTED ON THE
<br />PLANS.
<br />42. LOW PRESSURE AIR TEST AND VIDEO INSPECTION ARE REQUIRED FOR THE GRAVITY COLLECTION SYSTEM. ALTERNATIVE
<br />TESTING METHODS PROPOSED BY THE CONTRACTOR MUST BE PRE -APPROVED BY CITY OF ZEPHYRHILLS.
<br />43. MANHOLE FRAMES AND COVERS, AND C.O. CAPS ARE TO BE WATER TIGHT. IF NEEDED, EXISTING MANHOLE TOPS ARE TO BE
<br />ADJUSTED TO PROPOSED GRADE.
<br />44. INFLOW PROTECTION DISHES ARE REQUIRED FOR ALL MANHOLES: STAINLESS STEEL IN PAVED AREAS, ABS IN UNPAVED
<br />AREAS.
<br />45. ALL SEWER FORCE MAIN LINES AND GRAVITY SERVICE LINES ACCEPTED BY THE C11Y OF ZEPHYRHILLS MUST BE AT LEAST
<br />"
<br />FOUR INCHES 4 A EIGHT INCHES I DIAMETER, Y E AND E G NC ES 8 N D AME ER RESPECTIVELY, EXCEPT LATERAL SEWER LINES WHICH SHALLB NO
<br />LESS THAN SIX INCHES (6") IN DIAMETER )AND ACCEPTED BY THE CITY OF ZEPHYRHILLS TO A SANITARY CLEANOUT POINT
<br />,
<br />OF DEMARCATION (POD). A SANITARY CLEANOUT SHALL BE PROVIDED WITHIN 10 OF EXTERIOR BUILDING F ( ) E E TE OR BU LD NG WALL OR ALL
<br />WASTEWATER SERVICE CONNECTIONS. ALL SERVICE LINES SHALL ENTER A MANHOLE.
<br />46. A BALL CHECK VALVE FOLLOWED BY A PLUG VALVE SHALL BE INSTALLED AT THE C11Y OF ZEPHYRHILLS POD ON
<br />GOVERNMENT OR PRIVATELY OWNED FORCE MAINS DISCHARGING FROM PRIVATELY OWNED LIFT STATIONS CONNECTING INTO
<br />THE CITY OF ZEPHYRHILLS'S UTILITY MAINS.
<br />47. CONNECTION TO EXISTING MANHOLES AND/OR LIFT STATIONS SHALL BE BY CORE BORE WITH KOR-N-SEAL CONNECTORS.
<br />48. ALL ELECTRICAL AND CONTROL BOXES AT LIFT STATIONS SHALL BE PAINTED MANOR HOUSE BROWN (SHERWIN WILLIAMS).
<br />49. CONTRACTOR SHALL COORDINATE WITH CITY OF ZEPHYRHILLS ON THE LOCATION OF THE LS DRIVEWAY BEFORE INSTALLING.
<br />UTILITY SEPARATION
<br />50. EACH PROPOSED UTILITY SHALL BE LAID TO ACHIEVE THE MINIMUM HORIZONTAL SEPARATION BETWEEN IT AND OTHER
<br />UTILITIES IN ACCORDANCE WITH THE TYPICAL UTILITY HORIZONTAL SEPARATION DETAIL AND FDEP REQUIREMENTS.
<br />51. AT LOCATIONS WHERE A PROPOSED UTILITY CROSSES ANOTHER UTILITY, THE PROPOSED UTILITY SHALL BE INSTALLED IN
<br />ACCORDANCE WITH THE TYPICAL UTILITY CONFLICT DETAIL AND FDEP REQUIREMENTS.
<br />52. IN THE EVENT THAT A UTILITY CONFLICT CAN NOT BE RESOLVED BY MAKING A MINOR ROUTE ADJUSTMENT OR BY UTILIZING
<br />THE TYPICAL UTILITY CONFLICT DETAIL, THE CONTRACTOR SHALL SUBMIT A RELOCATION PLAN TO THE ENGINEER FOR
<br />APPROVAL PRIOR TO COMMENCING WORK. ALL RELOCATION EFFORTS SHALL BE SUBJECT TO THE APPROVAL OF THE
<br />ENGINEER AND ANY AFFECTED UTILITY COMPANIES.
<br />MAINTENANCE OF TRAFFIC
<br />53. THE CONTRACTOR SHALL REFER TO THE "2014 FLORIDA DEPARTMENT OF TRANSPORTATION ROADWAY AND TRAFFIC DESIGN
<br />STANDARDS" FOR FDOT DESIGN INDEXES AND 2014 "FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS
<br />FOR ROAD AND BRIDGE CONSTRUCTION" AS SUPPLEMENTS TO THE INFORMATION AND DETAILS PROVIDED IN THESE
<br />CONSTRUCTION DRAWINGS.
<br />54. ALL REFERENCED FDOT STANDARD INDEX DRAWINGS CAN BE FOUND AT WWW. DOT. STATE. FL. U S/RDDESI GN /DS/1 4/STDS. SH TM.
<br />55. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFE MAINTENANCE OF PEDESTRIAN AND VEHICULAR TRAFFIC AT ALL TIMES
<br />DURING THE DURATION OF THE PROJECT.
<br />56. THE CONTRACTOR SHALL MAINTAIN TRAFFIC IN ACCORDANCE WITH FDOT STANDARD INDEX 600 SERIES AND THE TECHNICAL
<br />SPECIFICATIONS. THE CONTRACTOR SHALL FURNISH, ERECT, AND MAINTAIN ALL NECESSARY TRAFFIC CONTROL AND SAFETY
<br />DEVICES THROUGHOUT THE PROJECT. ONE TRAFFIC LANE MUST BE MAINTAINED AT ALL TIMES WITH USE OF FLAGGER. ALL
<br />TRAFFIC LANES MUST BE OPEN FOR TRAFFIC AT THE CLOSE OF WORKDAYS. ALL SIGNING, BARRICADES, LIGHTING, AND
<br />FLAGGERS SHALL BE INCLUDED IN THE LUMP SUM COST.
<br />57. ALL PAVEMENT MARKINGS SHALL MEET CURRENT MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. STANDARDS, AND SHALL
<br />BE PAINTED IN ACCORDANCE WITH FDOT STANDARD SPECIFICATION SECTION 710.
<br />58. SIGNS AND BARRICADES TO BE ACCORDING TO FDOT MANUAL OF SAFE PRACTICES; REFERENCE FDOT INDEXES 600 THROUGH
<br />650 AND 17349 PER ROADWAY AND TRAFFIC DESIGN STANDARDS LATEST EDITION.
<br />PROJECT SPECIFIC
<br />59. THE CONTRACTOR SHALL PROVIDE A MINIMUM OF TWO (2) WEEKS NOTICE TO THE OWNER PRIOR TO CONNECTING THE NEW
<br />WATER MAIN TO THE AFB PUBLIC WATER SUPPLY (AFB-PWS). THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND
<br />SCHEDULING EACH CONNECTION WITH THE OWNERS OF THE PWS TO ENSURE THAT THERE ARE MINIMAL INTERRUPTIONS TO
<br />EACH SYSTEM.
<br />60. ALL UNDERGROUND UTILITIES MUST BE IN PLACE AND TESTED AND/OR INSPECTED PRIOR TO BACKFILL COMPACTION, ROAD
<br />BASE INSTALLATION, OR RESTORATION.
<br />61. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS ON ALL PRECAST AND MANUFACTURED ITEMS TO THE ENGINEER FOR
<br />APPROVAL. FAILURE TO OBTAIN APPROVAL BEFORE INSTALLATION MAY RESULT IN REMOVAL AND REPLACEMENT AT
<br />CONTRACTOR'S EXPENSE.
<br />62. ALL ROCKS OR STONES LARGER THAN 6" IN DIAMETER SHALL BE REMOVED FROM THE BACKFILL MATERIAL. BACKFILL
<br />MATERIAL PLACED WITHIN 1-FOOT OF PIPING AND APPURTENANCES SHALL NOT CONTAIN ANY STONES LARGER THAN 2" IN
<br />DIAMETER.
<br />63. ALL WORKMANSHIP AND MATERIALS USED IN THE CONSTRUCTION OF THIS PROJECT SHALL CONFORM TO FDOT'S STANDARD
<br />SPECIFICATIONS FOR ROADWORK AND BRIDGE CONSTRUCTION, LATEST EDITION, AWWA, NSF, AND THE LATEST CITY OF
<br />ZEPHYRHILLS STANDARDS, UNLESS OTHERWISE INDICATED.
<br />64. [ENGINEER TO ADD MO
<br />65. ABANDON PIPING IN PLACE:
<br />2" AND SMALLER CAP AND ABANDON IN PLACE.
<br />3" AND LARGER CAP AND GROUT FILL IN PLACE.
<br />UTILITY NOTES
<br />1. EXISTING WATER MAIN LOCATIONS ARE BASED ON THE "TOPOGRAPHIC SURVEY", PREPARED BY
<br />SIMMONS, BEALL AND TREABOUR, LLC PROFESSIONAL LAND SURVEYORS & MAPPERS (LB #8382),
<br />DATED 06/01/2021.
<br />2. EXISTING SEWER SERVICE LOCATIONS ARE BASED ON THE "TOPOGRAPHIC SURVEY", PREPARED BY
<br />SIMMONS, BEALL AND TREABOUR, LLC PROFESSIONAL LAND SURVEYORS & MAPPERS (LB #8382),
<br />DATED 06/01 /2021.
<br />3. CONTRACTOR TO NOTIFY ALL UTILITY COMPANIES FOR EXACT LOCATION OF UNDERGROUND UTILITIES
<br />PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
<br />4. CONTRACTOR IS REQUIRED TO FIELD VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND
<br />UTILITIES AND OTHER FEATURES PRIOR TO PROCEEDING WITH ANY PROPOSED CONSTRUCTION. THE
<br />CONTRACTOR MAY CONSULT THE UTILITY OWNER'S RECORD DRAWINGS, BUT THE UTILITY OWNER AND
<br />THE ENGINEER DO NOT GUARANTEE, BY IMPLICATION OR OTHERWISE, THE ACCURACY OF THESE UTILITY
<br />OWNERS RECORD DRAWINGS. SITE CONTRACTOR SHALL BE FINANCIALLY RESPONSIBLE FOR ANY
<br />MODIFICATIONS REQUIRED OTHER THAN SHOWN ON THE PLANS. CONTRACTOR SHALL FIELD VERIFY THE
<br />LOCATIONS, ELEVATIONS, AND DIMENSIONS OF ALL EXISTING UTILITIES AND SHALL NOTIFY THE ENGINEER
<br />IN WRITING OF ANY DEVIATION FROM THE PLANS.
<br />5. CONTRACTOR IS RESPONSIBLE FOR ALL UNDERGROUND CONDUITS AND WIRING TO SIGNS AND LIGHTING.
<br />6. SEE ARCHITECTURAL / MECHANICAL ENGINEERING PLANS FOR ANY PROPOSED FIRE PROTECTION
<br />DESIGNS & SPECIFICATIONS.
<br />7. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN EXCAVATING IN PROXIMITY OF ALL
<br />UTILITIES. EXISTING UTILITY LOCATIONS SHOWN ON THE PLANS ARE NOT EXACT OR GUARANTEED.
<br />8. ALL PROPOSED DOMESTIC WATER MAINS SHALL BE C-900 DR-18 PVC PIPE UNLESS OTHERWISE NOTED
<br />ON THE PLANS HEREIN.
<br />9. ALL PROPOSED RECLAIMED WATER MAINS (DENOTED AS RCW), IF PROPOSED, SHALL BE C-900 DR-18
<br />PVC PIPE UNLESS OTHERWISE NOTED ON THE PLANS HEREIN.
<br />10. ALL PROPOSED FIRE SERVICE LINES SHALL BE C-900 DR-14 PVC PIPE UNLESS OTHERWISE NOTED ON
<br />THE PLANS HEREIN.
<br />11. ALL SANITARY SEWER LINES SHALL BE SDR35 PVC PIPE UNLESS OTHERWISE NOTED ON THE PLANS
<br />HEREIN.
<br />12. IT IS THE RESPONSIBILITY OF THE CONTRACTOR DURING THE INSTALLATION OF ALL SERVICE LATERALS
<br />(SEWER AND WATER) TO COORDINATE ALL VERTICAL CLEARANCES/CONFLICTS WITH EXISTING AND
<br />PROPOSED PIPING, CONDUITS, AND SOFT UTILITIES (EXISTING AND FUTURE).
<br />ADDITIONAL UTILITY NOTES:
<br />1. ELECTRICAL SERVICE TO PAD MOUNTED TRANSFORMER SHALL BE RUN UNDERGROUND, FROM ROAD
<br />RIGHT-OF-WAY TO TRANSFORMER LOCATION. ASSOCIATED COST BY UTILITY CONTRACTOR.
<br />2. THRUST BLOCKS SHALL BE PROVIDED AT ALL BENDS, TEES, AND FIRE HYDRANTS.
<br />3. ALL DOMESTIC AND SANITARY LEADS TO BUILDING SHALL END AS SHOWN ON PLAN AND SHALL BE
<br />PROVIDED WITH A TEMPORARY PLUG AT END (FOR OTHERS TO REMOVE AND EXTEND AS NECESSARY).
<br />4. THE CONTRACTOR SHALL VERIFY THE DEPTH AND LOCATION OF EXISTING SEWER AND WATER LINES TO
<br />WHICH THE PROPOSED LINES WILL BE CONNECTED TO PRIOR TO DOING ANY OTHER WORK ON SITE. THE
<br />RELOCATION OF ANY WATER/SEWER FACILITY REQUIRED TO AVOID ANY PART OF THIS DEVELOPMENT IS
<br />THE RESPONSIBILITY OF THE CONTRACTOR.
<br />5. CONTRACTOR SHALL COORDINATE DRIVEWAY CLOSURE WITH PROPERTY OWNER, IF CLOSURE(S) IS DEEMED
<br />NECESSARY FOR CONSTRUCTION.
<br />6. REFER TO THE MECHANICAL/PLUMBING DRAWINGS FOR ALL UTILITY TIE-IN LOCATIONS.
<br />7. EXISTING UTILITIES LOCATED IN AREAS OF PROPOSED GRADING SHALL BE RAISED OR LOWERED AS
<br />REQUIRED TO ADHERE TO NEW GRADE. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING ALL
<br />UTILITIES AND COMPLIANCE WITH COVER REQUIREMENTS PER THE UTILITY PROVIDER FOR FINAL
<br />ELEVATIONS.
<br />8. EXISTING SEWER LINE FLOWS MUST BE MAINTAINED THROUGHOUT SITE CONSTRUCTION. IT SHALL BE THE
<br />RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL WORK WITH EXISTING SEWER AUTHORITES.
<br />CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ANY NEW SEWER TO REROUTE THE EXISTING
<br />SEWER AND THE NEW SEWER SHALL BE APPROVED BY THE UTILITY PROVIDER AND ALL BONDS,
<br />EASEMENTS, AS -GUILTS, OR OTHER REQUIREMENTS MET PRIOR TO PUTTING THE NEW LINE IN SERVICE.
<br />9. ALL CONSTRUCTION TO CONFORM TO THE APPLICABLE CITY OF ZEPHYRHILLS SPECIFICATIONS AND
<br />CONSTRUCTION DETAILS.
<br />10. CONTRACTOR SHALL COORDINATE DIRECTLY WITH THE LOCAL POWER, TELEPHONE, AND CABLE TV
<br />COMPANIES TO DETERMINE EXACT ROUTING OF EACH UTILITY SERVICE TO THE BUILDING OR SITE
<br />IMPROVEMENTS.
<br />11. CONTRACTOR TO SEE ELECTRICAL PLANS FOR COORDINATION WITH SITE LIGHTING AND
<br />TELECOMMUNICATION REQUIREMENTS.
<br />FIRE HYDRANT TEST DATA:
<br />ON 03/17/2021, MR. JOHN BOSTIC, UTILITIES DIRECTOR FOR THE CITY OF ZEPHYRHILLS UTILITIES
<br />DEPARTMENT PROVIDED FIRE HYDRANT FLOW TEST DATA FOR HYDRANTS AROUND THE SUBJECT SITE. FLOW
<br />WAS MEASURED ON TWO (2) EXISTING FIRE HYDRANTS: F.H. #1255 LOCATED NEAR 6585 N. DAIRY ROAD &
<br />WIRE ROAD, LOCATED WITHIN AN EXISTING DITCH, AND F.H. #1256 LOCATED NEAR 5251 N. DAIRY ROAD &
<br />WIRE ROAD. BOTH OF THESE EXISTING FIRE HYDRANTS ARE CONNECTED TO THE EXISTING 12" WATER MAIN
<br />THAT THE PROPOSED DEVELOPMENT IS PROPOSED TO CONNECT TO. FLOW TEST DATA WAS RECORDED ON
<br />BOTH HYDRANTS AND RESULTING INFORMATION IS AS FOLLOWS:
<br />FIRE HYDRANT #1255
<br />STATIC PRESSURE = 60 PSI
<br />RESIDUAL PRESSURE = 50 PSI
<br />FLOW ® PITOT READING= 1,060 GPM
<br />FLOW 0 20 PSI= 2,240 GPM
<br />FIRE HYDRANT #1256
<br />STATIC PRESSURE = 60 PSI
<br />RESIDUAL PRESSURE = 50 PSI
<br />FLOW 0 PITOT READING= 1,060 GPM
<br />FLOW 0 20 PSI= 2,240 GPM
<br />*NOTE: A COPY OF THE FIRE FLOW TEST RESULTS PROVIDED BY THE CITY OF ZEPHYRHILLS CAN BE FOUND
<br />IN THE LOWER RIGHT-HAND CORNER OF THIS SHEET (C-2.1).
<br />FacilitylD
<br />HydrantZ
<br />one
<br />Hydrant#
<br />STATUS
<br />INSPECTOR
<br />INSPECTION
<br />DATE
<br />LATITUDE
<br />LONGITUDE
<br />Address
<br />CrossStreet
<br />Manufactur
<br />Model
<br />BarrelDiam
<br />PUMPER
<br />HEIGHT
<br />STATIC
<br />RESIDUAL
<br />PRESSURE
<br />FLOW
<br />GPM
<br />FLOW PSI
<br />FLOW AT
<br />20PS1
<br />FLOW
<br />MINUTES
<br />RESIDUAL HYD
<br />ID NUM
<br />BONNET
<br />COLOR
<br />wH-Y-08525
<br />Y
<br />8525
<br />OPERATIONAL
<br />NICHOLAS OLIVER
<br />08/02/21
<br />28.27102482
<br />-82.18729530
<br />7800 GALL BLVD
<br />PRETTY POND RD
<br />AMERICAN DARLING
<br />B-84-B
<br />5.25
<br />19
<br />55
<br />45
<br />920
<br />30
<br />1810
<br />1
<br />wH-Y-08526
<br />BLUE
<br />wH-Y-08526
<br />Y
<br />8526
<br />OPERATIONAL
<br />BREN DON WRISTON
<br />08/02/21
<br />28.26971100
<br />-82.18747130
<br />7780GALLBLVD
<br />PRETTYPONDRD
<br />AMERICAN DARLING
<br />B-84-B
<br />5.25
<br />11
<br />55
<br />45
<br />840
<br />25
<br />1652
<br />1
<br />wH-Y-08526
<br />BLUE
<br />wH-Y-08527
<br />Y
<br />8527
<br />OPERATIONAL
<br />NICHOLAS OLIVER
<br />08/02/21
<br />28,26842182
<br />-82.18727860
<br />7600 GALL BLVD
<br />PRETTY POND RD
<br />AMERICAN DARLING
<br />B-84-B
<br />5.25
<br />20
<br />55
<br />45
<br />1000
<br />35
<br />1967
<br />1
<br />wH-Y-08678
<br />BLUE
<br />wH-Y-01255
<br />Y
<br />1255
<br />OPERATIONAL
<br />NICHOLAS OLIVER
<br />08/11/21
<br />28,26772962
<br />-82.18477050
<br />6585 N DAIRY RD
<br />WIRE RD
<br />AMERICAN DARLING
<br />B-84-B
<br />5.25
<br />20
<br />55
<br />50
<br />1130
<br />45
<br />3232
<br />1
<br />wH-Y-12009
<br />BLUE
<br />wH-Y-01256
<br />Y
<br />1256
<br />OPERATIONAL
<br />ANTHONYSTUART
<br />08/11/21
<br />28.26909282
<br />-82.18477550
<br />5251 north dairy rd
<br />Wire rd
<br />AMERICAN DARLING
<br />B-84-B
<br />5.25
<br />18
<br />65
<br />50
<br />1060
<br />40
<br />1919
<br />1
<br />Wh-y-01257
<br />BLUE
<br />wH-Y-01258
<br />Y
<br />1258
<br />OPERATIONAL
<br />NICHOLAS OLIVER
<br />08/02/21
<br />28.27082692
<br />-82.18563030
<br />7810 GALL BLVD
<br />PRETTY POND RD
<br />AMERICAN DARLING
<br />B-84-B
<br />5.25
<br />20
<br />55
<br />45
<br />1000
<br />35
<br />1967
<br />1
<br />wH-Y-01259
<br />BLUE
<br />**Note: Flow Test Results provided by the City of Zephyrhills, Mr. John Bostic, Utilities Director, via email on April 12, 2022.
<br />U)
<br />W
<br />H
<br />Q �
<br />V CY)
<br />U)
<br />U)'
<br />0
<br />Z
<br />U
<br />25 L
<br />U) W
<br />.SEAL
<br />* ' No. 52896
<br />-o S T OF
<br />z1//j/0NAL
<br />S .
<br />\�.
<br />S• E���`�
<br />on
<br />U
<br />U
<br />CQ
<br />C''9
<br />�
<br />W
<br />Ey
<br />W�E:a
<br />E
<br />A
<br />Z
<br />W
<br />W
<br />a
<br />IR
<br />C
<br />rn
<br />d
<br />=
<br />U
<br />E
<br />F-
<br />U
<br />C,I
<br />W
<br />W
<br />N
<br />O
<br />in
<br />CL
<br />W
<br />0 C
<br />W
<br />�
<br />u>a
<br />W
<br />d
<br />A
<br />Pci
<br />O
<br />z
<br />�
<br />a
<br />�I
<br />O
<br />�
<br />H
<br />A
<br />I
<br />Q'i
<br />Gc7
<br />A
<br />pw
<br />O
<br />U
<br />E
<br />m
<br />ado
<br />�
<br />c�
<br />�
<br />c i
<br />I
<br />E-
<br />z"'
<br />DRAWN BY
<br />CHECKED BY
<br />I
<br />TLF
<br />RCL
<br />DATE
<br />06/29/2020
<br />SHEET TITLE
<br />UTILITY NOTES
<br />SHEET NUMBER
<br />C-2.1