My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2947 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2947 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:14:37 AM
Creation date
2/19/2025 10:27:36 AM
Metadata
Fields
Template:
Building Plans
Street #
2947
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20414
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m <br />rn <br />aci <br />v <br />S <br />LO <br />a)O <br />J <br />O <br />Lo <br />ao <br />w <br />r— <br />00 <br />ATTIC VENTILATION CALCULATIONS <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />11300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />Must Provide U <br />( Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQINof <br />SQ. IN. of <br />Ventilators <br />ventilation <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />. . <br />Ventilation <br />Ventilation <br />(See Elev ) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />19.000000 <br />2.000000 <br />Floor <br />2276 <br />2185 <br />312 <br />1092 <br />78 <br />546 <br />561.0 <br />285.0 <br />276.0 <br />(Zone 1) <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: %4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PI AN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA/ <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />t <br />M <br />_ o <br />Z <br />z <br />r <br />Z <br />cn (9 <br />w <br />4. <br />•u — <br />OLL, <br />ZD <br />o <br />t� ~ <br />C)�� <br />m N <br />L11 <br />F— 8C <br />N M <br />11 <br />'aa M <br />= Q? <br />Q N <br />"- o <br />U <br />0 <br />N ao <br />rn ¢ ci <br />A ® <br />B D. <br />N �D <br />U) Z F c) Z" <br />c w <br />LU n <br />LN V Can a <br />in ¢ t <br />nrn <br />O <br />.Z <br />i"_ <br />LLV Tc <br />IZI9 �•• *•p <br />Q' r ao <br />� <br />'� <br />r �C c.V <br />a• Om <br />'F' <br />•s> <br />a � <br />°� <br />• �O S S 10 <br />��78��f dtllttttlt't�`�� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N A <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www. LennarTarn pa.corrt <br />�z <br />Lu <br />z <o- <br />F- <br />W¢W <br />U400 <br />OaWQ� <br />�O?W <br />aL <br />J <br />>o <br />zz <br />4 <br />z <br />C: <br />O <br />°0z <br />t- <br />,w <br />J01 <br />t'.. <br />O <br />Lu 5zm2 <br />.... `. '. <br />c <br />U OW Q <br />J <br />z¢z< <br />N <br />l� <br />Wt2<3 <br />OC <br />a<f W <br />I-o�s <br />�fo <br />Z <br />Z <br />a s <br />UJ <br />J <br />Ln <br />�—I <br />2: <br />Q <br />d W <br />EnF�o <br />M <br />000 <br />Z <br />Z <br />t-u9 <br />¢O <br /><o <br />Z <br />J z <br />06 <br />g <br />= <br /><UJ <br />rn <br />,1 <br />0- <br />to <br />o <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: MJAM ES <br />VERSION NO. <br />4v0 <br />SHEET NO. <br />5.0 <br />w <br />
The URL can be used to link to this page
Your browser does not support the video tag.