Laserfiche WebLink
(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />(2) 2x HEADER TO SIT <br />2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE STANDARD 3" DIA, TEE <br />SEE PLAN FOR HEADER SEE PLAN FOR SIZE THREADED 3" DIA. EXTENSION <br />CONNECTION SCREW OFF CAP (3" DIA.) —� <br />2x DEAD WOOD @ MID FOR CLEAN -OUT <br />J, POINT w/ (3)12d MIN. EXTENSION FROM <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1/2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />7 5/8" 8" 7 5/8" 8" <br />SOLID AREAS ARE ❑ <br />7 5/8" 8" <br />DOUBLE 2x TOP TONEAILS SPACED EXTERIOR FACE OF BLOCK ❑ STEEL AND GROUT ❑ ❑ <br />PLATE EVENLY WALL IS 1 1/2" MAXIMUM <br />HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR INTERIOR ❑ ❑ ❑ <br />FACE OF BLOCK WALL IS 2 1/4" <br />J <br />2x BLOCKING @EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />2x BOTTOM PLATE W/ (1)10d @ 8" <br />VARIES O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL <br />SCALE: N.T.S. SLI <br />12 <br />SEE TYPICAL WALL SECTION <br />(Np) <br />SEE ELEV. <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2X4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12)10d <br />(3)10d TOENAILS T&B <br />NAILS AT EACH STUD <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />F <br />++ <br />� STUD W/ (3)10d NAILS <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />b FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6' O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10)10d <br />r" NAILS AT EACH STUD <br />g <br />N 2x P.T. PLATE <br />�t 5/8" x 10" "J" BOLT @ 24" O/C MAX <br />2 W/ 8" EMBEDMENT <br />N <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. :::/ ­�::: <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONIC. FILLED CELL W/ <br />a STD. 90" HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />BLOCKING (TYP.) <br />\--ROOF TRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />Ir <br />'x <br />00 <br />0 <br />0 <br />I <br />< <br />MOUNTING BASE NOT SHOWN <br />In <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />o <br />= <br />SEAT FOR BLOCK IS POURED <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />E2 <br />GENERALNOTES <br />v <br />SLOPE FORWARD\ <br />El <br />FOR DRAINAGE <br />—SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />TO DRAIN DOOR OPENING DOOR OPENING <br />EXTERIOR <br />WALL CLEAN -OUT A WALL ❑ ❑ <br />SCALE: N.T.S. S4 FDI <br />1 ST COARSE 2ND COARSE 3RD COARSE <br />REFER TO WINDOW PRODUCT APPROVAL MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE <br />SHEETS FOR INSTALLATION INFORMATION BY COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE <br />MANUFACTURER. WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />TYPICAL SECTION THRU WINDOW KBNMASONRYLAYOUT rD <br />S4 SCALE: N.T.S. S4 <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT <br />a <br />a <br />a, e <br />a <br />Q a p <br />8STD. 90°HOOK 8" <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6'-0" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />NOTES: <br />FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />0 VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />O3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4" <br />FORM CONCRETE INSET TO <br />CREATE A SOLID BASE FOR <br />1/2"X9112" PLYWOOD BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />J <br />a <br />r W <br />O <br />FORM CREATES CONCRETE RECESS TO <br />2X4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />MOUNTING BASE SHOWN <br />IN POSITION <br />GARAGE ENTRY FORM DETAIL <br />2x6 MOUNTING BASE <br />SCALE: N.T.S. <br />�8x8x16 C.M.U. <br />GARAGE DOOR TRACK MOUNTING BRACKET <br />GARAGE DOOR ROLLER GARAGE DOOR TRACK <br />CONNECTION ASSEMBLY <br />GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />" <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />a <br />SCALE: N,T.S. <br />d a a BOTTOM OF MOUNTING B <br />BLOCK WALL. RECESSED SPACE <br />POURED CONCRETE BASE FOR <br />TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />S�cFp ,Do <br />�N <br />2x CRIPPLES @ — ' <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1/2" AT EA <br />STUD (USE SP6fOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />SOLID AREAS ARE <br />STEELAND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING -fit <br />VERTICAL JAM <br />5/8"DIA, x 8" J-BOLTS AT 6-3/4", 41-3/4", 71 ", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />W/MOUNTING ANGLE <br />rOP <br />a <br />aARAGE <br />)OOR <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1'-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1)LSTA30 <br />4' - 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />'­(2) 2x HEADER SEE PLAN <br />• INTERIOR HEADER: <br />S4 <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER <br />• EXTERIOR HEADERS: <br />ONLY <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH <br />SIDE <br />' <br />2x STUDS TYP. <br />00 <br />�R <br />{ SIMPSON HTT4 TYP. <br />Op <br />U.N.O. SEE N/S4 <br />** HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL (,_Q_� <br />SCALE: N.T.S. SL� <br />SIMPSON SIMPSON <br />SP4 SP2 <br />2X STUDS @ 24" O.C. <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />LINTEL <br />12 <br />(TYP.) SEE ELEV. <br />SIMPSON SP2 w/ (12)10d <br />NAI _ AT EACH STUD <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM C. <br />926 APPLY 3 LAYERS W/ TOTAL <br />THICKNESS 7/8" OVER METAL <br />LATH. FIRST 2 LAYERS 3/8" THICK <br />EACH. 3RD LAYER 1/8"THICK. <br />CRICKET AS REQUIRED <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING (" <br />O/C FIELD <br />2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />CARRIER/GIRDER TRUSS <br />SIMPSON HETA20 w/ (8)10dx1 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />IN KO BLOCK AT EA. STUD <br />MAIN SPAN <br />MOISTURE BARRIER <br />ROOF TRUSS <br />UPLIFT CONNECTOR <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />fI�I�7;rI�_�XI�i9le3Tilijl <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/STD. 900 HOOK IN K.O. BLOCK TYPICAL INTERIOR NOW <br />ALT. KNEEWALL ABOVE MASONRY WALL DETAIL E <br />S <br />SIMPSON SP4 <br />2X TOP PLATE <br />OVERLAPPING <br />TRUSS BOTTOM CHORD OR 2x4 <br />BLOCKING W/ 2-16d TOE NAILS <br />@ EACH END <br />w <br />a. <br />2x TOP PLATE <br />2-16d NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE FEQUAL @ 12" O.C. <br />SEE A/S3 FOR STAGGERED FROM BOT. <br />REINF. INFO. PLATE TO CONCRETE <br />SCALE: N.T.S. <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE NAILS TOTAL) EA. SIDE OF <br />%9,, SPLICE STAGGERED <br />• M <br />• -10d @ 8" O/C <br />ATTACH ALL <br />EXTERIOR STUDS <br />W/ 4 16d TOENAILS <br />TO P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL M <br />SCALE: N.T.S. S4 <br />F= 2240 LBS �7 <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />P.T. <br />ATE <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />RECESS <br />LINTEL <br />SIMPSON SIMPSON <br />SP4 —� SP2 -� <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />NAILED <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP4 <br />SIMPSON <br />SP1 <br />SIMPSC <br />SP4 <br />BEARING WOOD FRAME WALL � <br />4, SCALE; N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />P.L. 1.8E Fb=2400 PSI (AS PER PLANS) <br />HTT4 w! (18)10d NAILS (3610# SPF) <br />°o ° • <br />° o <br />HTTS w/ (26)10d NAILS (4670# SPF) • <br />° ° • DTT2Z wl (8)1!4" x 1 1/2"SDS (1835# SPF) <br />HDU2-SDS2.5 wl (6)1l4" x 21/2"SDS (2215# SPF) <br />HDU4-SDS2.5 wl (10) i!4" x 21/2"SDS (3285# SPF) <br />HDUS-SDS2.5 wl (14)1/4" x 21/2"SDS (4065# SPF) <br />° o ° • <br />° ° • <br />_ • <br />• HDU8-SDS2.5 w/ (20)1l4" x 21/2"SDS (5665#SPF) <br />• HDU11-SDS2.5 wl (30)114" x 21/2"SDS (6865# SPF) <br />• 5/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" <br />EMBEDMENT W/ WASHER &NUT <br />• FOR DTT2Z USE 1/2" DIA. x 12"EPDXIED <br />A.T.R. MIN. 8" EMBEDMENT wi WASHER & <br />p <br />- NUT <br />• FOR HDU8 USE 7l8" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT wl WASHER &NUT <br />• FOR HDU11 USE 1" DIA.. x 12" EPDXIED A.T.R. <br />MIN, 8" EMBEDMENT W/ WASHER &NUT <br />N <br />° <br />HTT / HDU TENSION TIE <br />SCALE: NTS S4 <br />10d NAILS @ 6" <br />STAGGERED <br />Zo I <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />ROOF TRUSS ABOVE <br />2X BLOCKING <br />a <br />2X8 P.T. BOTTOM P ATE C <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. B <br />C (MIN. (2) PER BOTTOM PLATE) C <br />SIMPSON <br />SP4 <br />-(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />11 <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />10d NAILS @ 4 A 10d NAILS @ 6" O.C. <br />STAGGERED STAGGE <br />RED <br />TRANSOM FRAMING <br />° ° BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES ° rE SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10)10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY ("R� <br />SCALE: N.T.S. <br />r' <br />SCALE: N.T.S. <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE NAILS TOTAL) EA. SIDE OF <br />%9,, SPLICE STAGGERED <br />• M <br />• -10d @ 8" O/C <br />ATTACH ALL <br />EXTERIOR STUDS <br />W/ 4 16d TOENAILS <br />TO P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL M <br />SCALE: N.T.S. S4 <br />F= 2240 LBS �7 <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />P.T. <br />ATE <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />RECESS <br />LINTEL <br />SIMPSON SIMPSON <br />SP4 —� SP2 -� <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />NAILED <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP4 <br />SIMPSON <br />SP1 <br />SIMPSC <br />SP4 <br />BEARING WOOD FRAME WALL � <br />4, SCALE; N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />P.L. 1.8E Fb=2400 PSI (AS PER PLANS) <br />HTT4 w! (18)10d NAILS (3610# SPF) <br />°o ° • <br />° o <br />HTTS w/ (26)10d NAILS (4670# SPF) • <br />° ° • DTT2Z wl (8)1!4" x 1 1/2"SDS (1835# SPF) <br />HDU2-SDS2.5 wl (6)1l4" x 21/2"SDS (2215# SPF) <br />HDU4-SDS2.5 wl (10) i!4" x 21/2"SDS (3285# SPF) <br />HDUS-SDS2.5 wl (14)1/4" x 21/2"SDS (4065# SPF) <br />° o ° • <br />° ° • <br />_ • <br />• HDU8-SDS2.5 w/ (20)1l4" x 21/2"SDS (5665#SPF) <br />• HDU11-SDS2.5 wl (30)114" x 21/2"SDS (6865# SPF) <br />• 5/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" <br />EMBEDMENT W/ WASHER &NUT <br />• FOR DTT2Z USE 1/2" DIA. x 12"EPDXIED <br />A.T.R. MIN. 8" EMBEDMENT wi WASHER & <br />p <br />- NUT <br />• FOR HDU8 USE 7l8" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT wl WASHER &NUT <br />• FOR HDU11 USE 1" DIA.. x 12" EPDXIED A.T.R. <br />MIN, 8" EMBEDMENT W/ WASHER &NUT <br />N <br />° <br />HTT / HDU TENSION TIE <br />SCALE: NTS S4 <br />10d NAILS @ 6" <br />STAGGERED <br />Zo I <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />ROOF TRUSS ABOVE <br />2X BLOCKING <br />a <br />2X8 P.T. BOTTOM P ATE C <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. B <br />C (MIN. (2) PER BOTTOM PLATE) C <br />SIMPSON <br />SP4 <br />-(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />11 <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />10d NAILS @ 4 A 10d NAILS @ 6" O.C. <br />STAGGERED STAGGE <br />RED <br />TRANSOM FRAMING <br />° ° BEYOND. <br />-PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES ° rE SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10)10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />2X8 P.T. BOTTOM <br />PLATE <br />D <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY ("R� <br />SCALE: N.T.S. <br />r' <br />w <br />�r <br />Z M <br />_ O <br />zCD <br />z <br />U) <br />ClV) <br />0 <br />�--� LU <br />.O Lu <br />oco <br />.� � <br />o <br />m <br />W <br />aimN <br />M co <br />COM <br />C) <br />O o N <br />L U_ W <br />tv o <br />< <br />in be o <br />m <br />u, g:S <br />�Qa <br />B Ds <br />N C•B•D C <br />N �O <br />m , <br />Z W M,-aZ z <br />U) <br />LLg <br />LLIy N <br />a <br />�NJ_�c�o <br />0 Z ago' <br />c <br />0 Nf ig 6C-.6 t <br />WL <br />I a � <br />`��ww <br />X <br />b <br />A � <br />F , <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Oz <br />Up <br />Uj <br />f� <br />'� <br />o¢o�� <br />zV�Q <br />W <br />J <br />uj <br />CC N <br />V o <br />Q <br />L- <br />a <br />z zo <br />rz <br />zZ <br />O= <br />f <br />V <br />Ch <br />� <br />cn <br />-. -I <br />o�Z <br />o <br />f- <br />fog <br />W <br />0�� <br />[!a! <br />(114 <br />- ¢ T <br />� <br />Q <br />N <br />¢¢fa <br />o��o <br />z <br />z <br />r4 <br />u o�u <br />r zpp i <br />J <br />� <br />C <br />a�� <br />FYO <br />Uj <br />G <br />Q F ' <br />dam- <br />Z <br />z <br />SUS <br />z <br />� <br />_ <br />< f <br />On <br />000 <br />r-1 <br />d <br />V) <br />o <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: M)AM ES <br />VERSION NO. <br />4w0 <br />SHEET NO. <br />S4 <br />