My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2955 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2955 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:25:45 AM
Creation date
2/19/2025 10:27:57 AM
Metadata
Fields
Template:
Building Plans
Street #
2955
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20608
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
co <br />0 <br />00 <br />0. <br />00 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />N. <br />T-n-M- <br />off <br />c <br />a <br />12 <br />5� <br />15'-0" RIDGE VENT <br />12 <br />�5 <br />EXTENDED <br />OVERHANG TO <br />BE CENTERED - <br />ON DOOR <br />14'-0" RIDGE <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />------------------ <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />12 <br />�5 <br />REAR ELEVATION - Al <br />T.O.M. - — <br />HDR HGT. <br />---------- -- it <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />TEXTURED TEXTURED <br />CEMENTICIOUS <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />FINISH ON C.M.U. <br />(TYP.) (TYP.) <br />F.FL. - <br />M RIGHT ELEVATION - Al <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w! portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40°% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"*CALCULATIONS BASED ON THE FOLLOtMNG VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA! UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SO, FT. <br />t9 <br />_zo <br />z <br />z� <br />U) zC:N <br />(D <br />W Cf> <br />Q)(0 <br />W <br />M <br />�U — <br />O W <br />N <br />m <br />i� <br />o <br />m <br />W <br />F- o— V <br />0)M M <br />CO <br />` <br />� (D <br />U 31 <br />,'0 <br />O O N <br />L 06 <br />C Y <br />¢ o <br />a-00 <br />aro <br />a Q ci <br />B D• <br />N <br />=AJ4 <br />U) o, ak <br />U' Z W N8z G <br />J 0? a !a <br />W aU " <br />W <br />a 15 <br />CL - <br />m <br />Z 0cc - &o <br />ZH .�A , 6lUM 1 P <br />` <br />!�ca <br />tp <br />Wd�`` <br />�'v ,� o <br />-V,Kvw: bs <br />U <br />'• <br />® 5 <br />��'7rIi111 I1161A`��,� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />oz <br />za <br />of <br />f¢ <br />Zwai�Y� <br />U400 <br />O <br />z uJ <br />#oZZ <br />Q <br />a J <br />C <br />L.0 <br />� <br />SWti© <br />m <br />L <br />a <br />z U <br />W/ <br />Y U <br />,. <br />QZ <br />Lij <br />C) <br />Z Z <br />��//'�� <br />VJ <br />N� <br />C <br />Z <br />OZ <br />JW <br />CC <br />�o <br />J�� <br />L.1Lu <br />-,.._ <br />U 0 <br />zgz <br />oyu9� <br />z< <br />h <br />�o-E <br />z <br />�--I <br />Ce <br />W <br />Lr) <br />� <br />Q <br />W <br />Q <br />z <br />U <br />azLU � <br />$ o <br />Z <br />(V <br />d- <br />z <br />U <br />9Z <br />:o <br />m <br />06 <br />z <br />g <br />= <br />a UJ <br />rn <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAM ES <br />VERSION NO. 4mO <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.