My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2955 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2955 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:25:45 AM
Creation date
2/19/2025 10:27:57 AM
Metadata
Fields
Template:
Building Plans
Street #
2955
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20608
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br /># 14 copper to lights & outlets <br />NEMA 1 #12 Copper to 20 amp ckis <br />200 AMP <br />#10.2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />MAIN <br />2/0 or 4/0 SER Alu <br />22 p <br />150 amp <br />I <br />POWER CO. FEED <br />I <br />4 Bare Cu Ground <br />INTERSYSTEM <br />r44ROUNDING <br />BONDING WIRE <br />j <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: <br />unless otherwise noted, <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the poor shall be equipped with an <br />GFI <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />I <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />OWNER'S S I T E <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />I <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />/2 \ <br />18" for sinks and ranges installed in corner counters. <br />i <br />1 <br />ELECTRICAL KEY <br />/ ROUGH -IN FOR / <br />OPT. CLG. FAN/ j <br />DUPLEX CONVENIENCE OUTLET <br />LIGHT PRE -WIRE <br />DUPLEX OUTLET ABOVE COUNTER <br />/ <br />S.D. dVP <br />wP WEATHERPROOF DUPLEX OUTLET <br />/ / <br />' <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />bw <br />G <br />00 <br />g <br />SPECIAL PURPOSE OUTLET <br />I <br />� <br />DUPLEX OUTLET IN FLOOR <br />I f <br />220 VOLT OUTLET <br />WALL SWITCH <br />� <br />REI3 <br />THREE-WAY SWITCH <br />I <br />FAMILY R M <br />I , <br />24 FOUR-WAY SWITCH <br />I 12 <br />rn <br />R RHEOSTAT SWITCH <br />/ <br />CEILING MOUNTED LIGHT FIXTURE <br />I �/ <br />ROUGH -IN FOR <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />w <br />to <br />o <br />1-0 WALL MOUNTED LIGHT FIXTURE <br />U.C. OUTLET <br />ORECESSED LIGHT FIXTURE <br />I FOR DW <br />N <br />I U.C. OUTLET <br />I <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />+PZ. <br />eo <br />46 TRACK LIGHT <br />ro I <br />FLUORESCENT LIGHT FIXTURE <br />GFI <br />� � � —-------�— <br />_ <br />O EXHAUST FAN <br />Jn GFI [ GF <br />PA 1 V CAF E / —, <br />;O) EXHAUST FAN/LIGHT COMBINATION <br />` <br />�12/ <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />D.W. <br />SINK I DIS <br />02 <br />CH CHIMES (OPTIONAL) <br />— — U. <br />N <br />o <br />Fl3 PUSH BUTTON SWITCH (OPTIONAL) <br />PENDANT AS <br />/ <br />PER SPECS \ <br />I� PUSH BUTTON SWITCH - DOOR BELLCn <br />LO <br />o <br />SD SMOKE DETECTOR— <br />= <br />`v <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />AC PAD / <br />/ 3 GFI GFI <br />J <br />TELEPHONE (OPTIONAL) <br />�_ <br />FT�TELEVISION (OPTIONAL) <br />� <br />DEDICATED RECEPTACLE <br />H.B. FOR MICROWAVE RANGE <br />0 <br />0 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />GFI DISC. HOOD PER SPECS <br />�I <br />O THERMOSTAT <br />ELECTRIC METER <br />•o <br />i <br />wl ELECTRIC PANEL <br />_I DISCONNECT SWITCH <br />O° <br />SPEAKER (OPTIONAL) <br />o <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />r„ <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />M <br />8B (1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />-- <br />VERIFY LOCATION <br />ELECTRICAL PANEL <br />2 CAR <br />GARAGE <br />GFI FOR <br />OO <br />GFI <br />—I <br />n ■ _GFI , . <br />_• <br />II �� •� �� <br />A.F.F. <br />�- <br />111 <br />4 <br />�I►%�IIIIIIIIIIIIIIIII�IIIII�11111111111 <br />n <br />L—, �► <br />j �� II ul II II <br />•• 111 , 111 = <br />BEDROOM 2 <br />_ <br />BEDROOM 3) BEDROOM 4 <br />12. <br />ROUGH -IN FOR <br />OUGH-IN FOR <br />I;. OPT. CILG. FANIG v��IGHT PRE -WIRE <br />LIGHT PRE -WIRE <br />OPT. CLG.FAN/ <br />LIGHT PRE -WIRE <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />i r <br />j;' <br />o <br />ZCID <br />z <br /><i <br />-I <br />d <br />13 <br />Cn C9 <br />�w <br />�o <br />.0 W <br />O� <br />o <br />�N <br />(� t- <br />U <br />�I- <br />m N <br />L11 pp <br />® t U <br />N M m <br />M <br />p M <br />g? <br />`7i <br />O_oo <br />t U" 00 <br />U <br />00 <br />CO a o <br />4cm <br />LO2L: <br />9 Q d <br />A <br />BD®N <br />T <br />I� <br />;r_ <br />- <br />N N <br />O M O W <br />y <br />Ilia <br />Z �NOZ l:e z <br />tJi o <br />W a "V w <br />10W CD <br />�< °� o <br />� E� <br />Z <br />UM <br />W C"I c a <br />d <br />O U U O <br />WWW.FDSENG.com ❑ Li <br />ao <br />O <br />N <br />0 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0Z <br />fQ <br />z <br />r w¢iYtr <br />ODUO <br />LL <br />ce0.W <br />0 <br />u Z LL 0 <br />OO <br />L <br />Q <br />u., <br />Q) <br />� <br />�Z <br />U <br />w <br />Z <br />.� <br />L.l.l <br />Z <br />J w <br />f <br />U <br />_ <br />cri <br />O <br />J <br />O OZ <br />x <br />Z <br />j0�� <br />x. <br />I\ <br />< <br />y�ZZ a < <br />Q <br />g�C <br />o <br />Z <br />J <br />� <br />W <br />LU <br />j5 <br />z <br />z <br />DNS <br />C1 <br />0 <br />00 <br />g <br />{ yrLu <br />... <br />= <br />-1 -12 <br />of <br />rn <br />T-1 <br />a <br />cn <br />s <br />SCALE : AS NOTED. <br />DATE : 10/2/2018 <br />TECH: MJAM ES <br />VERSION NO. 4n0 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.