My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2964 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2964 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:44:08 AM
Creation date
2/19/2025 10:28:36 AM
Metadata
Fields
Template:
Building Plans
Street #
2964
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20687
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />d <br />HEEL <br />HDR HGT. <br />TEXTURED <br />o CEMENTICIOUS <br />co FINISH ON C.M.U. <br />(TYP.) <br />ED <br />12 <br />5� <br />Q <br />Cl--------- <br />F.FL. <br />12 <br />5� <br />12 <br />14'-0" RIDGE VENT <br />12 <br />7__�5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />1' 0" <br />— --— — — — — — — — — — — — — — — — — — — -- -- ----- <br />MININININININ I <br />12 <br />�5 <br />15'-0" RIDGE VENT <br />FRONT ELEVATION - Al <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />T.O.M. <br />HDR HGT. <br />-0 <br />4 <br />6" FASCIA <br />c <br />(TYP) <br />2'-0" <br />c <br />TEXTURED _ <br />C:) <br />CEMENTICIOUS o0 <br />00 <br />J <br />FINISH ON C.M.U. cO <br />(TYP.) <br />----------I r ----------------------------------------------------- F.FL. <br />I LEFT ELEVATION - Al- <br />M <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />—CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />C9 �_ <br />Z cM <br />O <br />O <br />z� <br />z� <br />Q <br />a <br />Q) <br />+_J W <br />•V - <br />O,,, <br />C/) <br />C, <br />o <br />m N <br />W <br />E <br />N M <br />� M <br />min UUUU <br />O o N <br />"- <br />Ca <br />_C ib <br />o <br />¢m <br />o- o <br />U.)n� <br />9 Q o <br />B D0 <br />N� <br />N N <br />rn <br />-w O <br />v M Q� 00 <br />Z LU` p 0 6. O z <br />WI4 <br />II..,� U_ . C <br />LU h N W <br />>.Eu- o a <br />W V L <br />Z O rgC <br />° mow= x <br />S -, 5 /g <br />M; <br />LLCn <br />W `�td <br />ob <br />_e v O <br />;• <br />\ <br />LL <br />S510'ir�' <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Z <br />uJ <br />¢f <br />a <br />(/) <br />z <br />w Y tY <br />z o 0 <br />Z�Ix <br />Up,u <br />_o <br />U <br />J <br />W'0 - <br />� <br />W <br />00� <br />^i <br />J <br />W <br />Zo <br />Y V <br />Z <br />T� <br />U <br />� <br />Z <br />J Q <br />O <br />i <br />F- <br />' <br />oQZ <br />Y <br />I'- ;�T <br />OJ <br />TF <br />1 <br />ILL.Z <br />Wa< Q JQ <br />Q <br />or�-0 <br />Z <br />Z <br />woo <br />a2!_ <br />J <br />Lr) <br />W <br />� LU w <br />��o <br />V <br />O <br />Z <br />Z <br />Q <br />9z <br />0o <br />Z <br />g <br />= <br />v7 O <br />J z <br />g <br />° <br />a-u <br />o <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAMES <br />VERSION N0. 4mO <br />SHEET NO. <br />3.1 <br />- <br />1 -T� - 1 �Or 7=1 L0 i _ r�—flti-t711;f1=eE3 i m�� -.m d. t o'dn �r,'Al "n .1. .�i a i, i :. i I Il <br />
The URL can be used to link to this page
Your browser does not support the video tag.