x <br />1 <br />00 <br />Q <br />CORNER OF <br />HOME <br />s GARAGE SIDE <br />a[ 00 <br />a <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />0 0 0 <br />01 5'-0" <br />STUB -OUT FOR 0 c 9 <br />GAS METER <br />or <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />`*ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />1304" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />1 SIMPSON HTS20 OR 4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />1514" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />w <br />co <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />Rln(,F I INF <br />+ <br />+ + + + + + l + 4 <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + t + + + + + zo <br />+ + + + + + + . + + + + + + <br />.} <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />F + <br />+ <br />+ <br />'-0" (TYP.) <br />6-0'+ <br />6-0" <br />+ <br />+ + <br />+ + <br />F <br />+ + <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+++ <br />+ + <br />+ + <br />++ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ F <br />++ <br />+ <br />+ 4. <br />+ t t + + t + + <br />+ <br />+ + + +- 'f <br />t + <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + + <br />+ + <br />+ <br />++ <br />++++++++ <br />+ <br />n <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />BRIDGE LINE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER, IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />90 2.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />r <br />FILL CELL STD, 90" HOOK BOND BEAM <br />11 <br />\ 0�_ 1� <br />rn -- — <br />w <br />j STD. 90• C� _ CONT. #5 <br />BAR � I HOOK F IF---]F- BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />J <br />SEE PLAN FOR REQ'D <br />�� SHEATHING PER PLAN <br />COLUMN AND y. <br />CONNECTION <br />'r , 1 TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />\ MASONRY WALL OR <br />INTERIOR BRG. WALL <br />\\� TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # 2nd FLOOR <br />above to bearing below. STUU DS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />r <br />i <br />1/8" min. ) Small gap <br />2" max. <br />2' min. <br />4 max. <br />i <br />yyeb Stiffener Fastener Schedule <br />r i <br />- <br />� <br />V <br />Joist Bearing Location <br />Series Depth I End_ Intermediate <br />BCI5000s 11-7/8" 2-8d 3-8d <br />Clinch nails 1 / " 2-8d - 5-8d <br />9-1/2 2-8d 2-8d- <br />when BCI6000s® 11-7/8" 2-8d _ 3-8d <br />possible BCI6500s® 14" 2-8d 639d <br />16" 2-8d 6-8d <br />1) Support back of web during nailing to prevent damage to - " --- 8 <br />11-7/8 2-8d 3-8d <br />web -flange connection. _ ® _ — <br />�--- BCI60s 14 2-8d 5-8d <br />2) Block solid between joists for full length of span. Tight fit -- 16" 2-8d 6-8d <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 11-718" 3-16d 3-16d <br />4 Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. BCI 90se 14"J5-11:6d�16-16d <br />6d <br />ogrequired when indicated or 4" ma. 16"6-1 <br />2x-: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or--20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />' Provide adequate bearing <br />for each lapped joist. <br />10dnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall orILI <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />__73 <br />6"A 1 " ROUND HOLE MAY 6�� 6�� DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER L LARGER THAN 1Y2" <br />THE WEB. PROVIDE AT OUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />8 <br />1'-0" <br />1'-1" <br />1'-2" <br />V-2" <br />1'-3" <br />1'-3" <br />1'-7" <br />1'-11" <br />2'-4" <br />2'-9" <br />T-2" <br />3'-7" <br />---Any 16" jois_t _ - <br />12 <br />V-0" <br />V-1" <br />1'-2" <br />1'-2" <br />1'-3" <br />1'-9" <br />2'-4" <br />2'-11" <br />T-7" <br />4'-2" <br />4'-9" <br />5'-4" <br />_ <br />---.Span (ft) 16 <br />1'-0" <br />V-1" <br />1'-2" <br />V-2" <br />1'-7" <br />2'-5" <br />3-2" <br />3'-10" <br />4'-9" <br />5'-7" <br />6'-4" <br />7'-2" <br />20 <br />V-0" <br />1'-1 " <br />1-2" <br />V-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11 " <br />6'-11 " <br />T-11 " <br />8'-11 " <br />-- —� - — 24 <br />1'-0" <br />1'-1 " <br />V-2" <br />V-3" <br />2'-5" <br />3'-7" <br />4'-9" <br />W-10" <br />T-2" <br />8'4" <br />9'-0" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7.%2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />`-,.,Install tight to top flange. <br />Joist hanger <br />Filler block. <br />Nail with <br />\" <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />i <br />- Backer Block <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />7. <br />0.6 X Joist <br />o depth <br />emu <br />i• \�� l { <br />I -JOISTS BUCKETS <br />N.T.S. <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />GIRDER TRUSS <br />2X TOP PLATE <br />5/8" 0 <br />THRU <br />BOLT <br />2 X B.U.0 <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A • • (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" v <br />CENETERED @PIPE <br />PENETRATION <br />d e o' <br />a <br />A. a' ° d•• o <br />. _ i <br />FINISH GRADE - <br />SLEEVE THRU STEMS • <br />SEE PLAN FOR--'•• • .. . • <br />FOUNDATION INFO ' a d' <br />STEM FOUNDATION <br />GRADE <br />.o <br />r— REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />e <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE PLUMBING LINE <br />PENETRATION <br />o e . <br />zI �, <br />° w <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @PIPE <br />PENETRATION PLUMBING LINE <br />G TO .4 ° . . <br />0 <br />a <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />LO <br />z�® <br />J <br />I`� Z <br />V1 0 <br />C1 <br />Q) <br />N <br />4--J w <br />� o <br />0 LU <br />Ln tv <br />.0 <br />� <br />U <br />M <br />� <br />LU <br />M <br />MR <br />c <br />a;$o <br />E D. <br />c�B'�tr' <br />,UI' <br />U) <br />Z`z <br />LL <br />io Lu 0 V a <br />�' <br />= i <br />N 2 <br />Q <br />N <br />O W N&L <br />�� �PWW,FDS ' G.COM <br />• <br />IY -J 4]� <br />• <br />cJ A,P' <br />rr�r XP '••.......••'o�� ,. <br />,�. 40ROFE55� <br />\N,� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential Bth Edition. Engineer's signature and seel is only for <br />the structural engineedng portions of the drawing pages bearing <br />Engineer's signature end seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />W� <br />asi <br />�AA o <br />ga$ <br />u <br />wl <br />V <br />cu <br />> <br />~ <br />0C <br />0 <br />� <br />a <br />z <br />I � <br />0++ <br />U <br />•_ <br />`J <br />rfj z <br />o8 <br />U5im <br />Z <br />*� <br />J <br />z <br />W <br />198 <br />C)Q <br />co <br />Z <br />t <br />00 <br />g <br />Ln <br />o <br />SCALE : AS NOTED <br />DATE : 10/4/2018 <br />TECH: JMUROSKI <br />VERSION N0. 4nO <br />SHEET NO. <br />SN 1 <br />