2971 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2971 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:52:35 AM
Creation date
2/19/2025 10:28:55 AM
Metadata
Fields
Template:
Building Plans
Street #
2971
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20514
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIMPSON HGAM11 <br />W/ <br />(4)1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & (A <br />1/4"x2 3/4" <br />TITEN TO CMU <br />SEE STRUCTURAL NOTES AND BACKNAIL W! (2)16d NAILS BACKNAIL w/ (2)16d NAILS SIMPSON H10A w/ (18) SIMPSON SP4 w! 6 10d x <br />TOENAIL W/ (2) 16d NAILS SIMPSON H10A w/ (18) ( ) <br />NAILING SCHEDULE FOR 2"x4" 10d x 1 12" AT EA. 1 12" AT EA STUD USE BACKNAIL wl 2 16d NAILS SIMPSON H1 OA w/ 18 <br />2"x4" OUTLOOKER SEE STRUCTURAL NOTES AND 10d x 1 12" AT EA. SEE STRUCTURAL NOTES ( () ( ) <br />SHEATHING DETAIL OUTI OOKER OUTLOOKER SPA FOR 2 6 WALL USE 10d 1 12" AT EA <br />@ 24" O.C. <br />NAILING SCHEDULE FOR OUTLOOKER <br />@ 24" O.C. AND NAILING SCHEDULE <br />TOP CHORD <br />SHEATHING DETAIL <br />FOR SHEATHING DETAIL <br />BLOCKING FOR <br />• <br />FIRST FOUR <br />a5° t <br />24" MAX. <br />TOP CORD <br />45°t <br />2X4 CONT'L" BRACE <br />TOP CORD BLOCKING <br />TROWSOFRUSSES @ <br />SIMPSON H10A w/ (18) <br />OR FIRST BLOCKING <br />FASTENED W/ 2 10d 3" <br />FOR FIRST FOUR ROWS <br />EDGES OF 2x4 CRO BRACE <br />10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24" O/C. CMID HEIGHT <br />OF TRUSSES @ EDGES <br />SHEATHING APPROX. 8" FROM <br />OUTLOOKER <br />EDGES OF <br />OF SHEATHING TYPICAL <br />TYPICAL @ RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />SHEATHING TYP. <br />2X4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />48" O.C. EACH JOINT W/ (3) 10d <br />AT LEAST 90% OF WEB <br />@ 8'-0" O/C. <br />EXTEND AT LEAST 90% OF <br />' <br />& (2)1 Od TOE NAILS @ <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />iMAX. <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />2x6 P.T. GABLE TRUSS <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />• <br />SILL 1/2" CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROM LEDGER TO <br />' <br />7/16" OSB SHEATHING <br />FATTACHEDW/10d <br />& (2)10d TOE NAILS @ <br />BLOCKING <br />EA. END <br />NAILS @ 6" O.C. EDGES <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />F��1/2" <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />10dX3" 3" O/C <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />CDX PLYWOOD OR 7/16" <br />THROUGH CHORD <br />CORD ATTACHED W/ (2)16d TOENAILS <br />OSB SHEATHING ATTACHED <br />10d NAILS 6" O.C. <br />INTO 2"x6" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />w/ @ <br />EDGES AND 12" O.C. FIELD <br />2x4 PANEL BLOCKING @ <br />2x4 "T" ON TOP OF PANEL BLOCKING, <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />O.C. FOR THE FIRST (4) <br />FASTEN WITH 10dx3" @ 4" O/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />NOTCH "L" BRACE HERE <br />ROWS OF TRUSSES FRO <br />@ 48" O.C. <br />5/8" x 10" "J" BOLT @ 48" O.C. <br />WEEP SCREED <br />EA. END TYP. TOP & <br />MOISTURE BARRIER <br />BOTTOM ATTACHED w/ <br />5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM <br />SIMPSON HETA20 w/ (8)10dxl 1/2" NAILS AT V-0" <br />INSTALLED PER MANUF, <br />16d TOENAILS <br />PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />10dxl 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7)10d NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4)1/4"x21/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION <br />1 O.C. MAX) w/ MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />GABLE WEB SECTION <br />E CT O A , <br />J N <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />10d NAILS & (4)1/4"x21/4" SCALE: N.T.S. <br />SI:J <br />SCALE: N.T.S. <br />Srj <br />TITEN ON OUTSIDE <br />SIMPSON H10A w/ (18) <br />BACKNAIL W/ (2)16d NAILS <br />SP8 FOR 2x8 WALL) <br />L <br />2) <br />SEE STRUCTURAL NOTES OUTLOOKER <br />AND NAILING SCHEDULE <br />2x4 OUTLOOKER <br />FOR SHEATHIN <br />DETAIL <br />@ 24" 0/C <br />2x4 OUTLOOKER @ 24" <br />TOP CORD <br />4" MAX. O.C. (OPTIONAL -SEE <br />BLOCKING FOR <br />ELEVATIONS) <br />FIRST FOUR ROWS <br />DOUBLE TOP PLATE <br />OF TRUSSES @ <br />2x4 CROSS BRACE APPROX. 8" <br />2"x4" CROSS BRACE <br />24" MAX. <br />EDGES OF <br />F STEN <br />FROM RIDGE FASTENED AT <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />EACH JOINT & (2T <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />TOE NAILS @ EA. END <br />EACH JOINT W/ (2) <br />AT LEAST 90% OF WEB <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING/,1/2"CDX <br />PLYWOOD OR <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />(2) 16d <br />7/16" OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />NAILS <br />ATTACHED wl 10d NAILS <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />@ 6" O.C. EDGES AND 12" <br />AND 12" O.C. FIELD <br />END TYP. TOP & <br />O.C. FIELD <br />(2)16d NAILS <br />BOTTOM ATTACHED <br />48" <br />2x BLOCKING <br />W/ (2)16d TOENAILS <br />2x4'T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />M <br />2x4 "T" ON TOP OF PANEL <br />SIMPSON HGA10KTw/ (4)1/4"x1 1/2" <br />10dx3" @ 4" 0/C <br />BLOCKING, FASTEN WITH <br />SDS SCREWS TO TRUSS & (4)1/4"x3" <br />10dx3" @ 4" O/C <br />SDS SCREWS TO PLATES AT 36" O.C. <br />SIMPSON SP2 w/ (12)10d <br />2x4 LEDGER (MATCH BOTTOM <br />NAILS AT EACH STUD <br />DBL. TOP PLATE <br />CHORD SLOPE OF ADJACENT <br />TRUSS) STUD WALL (SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />10d x 1 12" AT EA. 2x4 OUTLOOKER <br />-REFER TO DETAIL J <br />SEE STRUCTURAL',,,_OUTLOOKER <br />F@ 24" O/C <br />ON SHEET S5 FOR <br />NOTES AND NAILING <br />TOP CORD <br />X-BRACING, AND TOP <br />N <br />SCHEDULE FOR <br />BLOCKING FOR <br />CHORD BLOCKING <br />to <br />`� <br />°° <br />SHEATHING DETAIL <br />FIRST FOUR ROWS <br />INFORMATION <br />OF TRUSSES @ <br />1 <br />1 <br />1/ „. <br />2"x4"CROSS BRACE <br />24" MAX. <br />EDGES OF <br />WOOD TRUSSES <br />00 <br />to <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />-2x4 RAT RUN BRACING <br />„ " <br />EACH JOINT W/ (2) <br />lit <br />AT LEAST 90% OF WEB <br />AT 24" O.C. ON TOP OF <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />BOTT. CHORD FOR 4 <br />TRUSS SPANS <br />^ <br />NAILS @ EA. END <br />GABLE TRUSS <br />ATTACHED W/ 2 -16d <br />`7LJt1� <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR 7/16" <br />AT EA. TRUSS JOINT <br />(2) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 6" LAMINATIONS W/ (2) ROWS OF <br />@ 48" O/C FOR THE <br />FIRST (4) ROWS OF <br />(2)16d NAILS <br />OSB SHEATHING ATTACHED <br />W/ 10d NAILS @ 6" O.C. <br />-2x4 BLOCKING @ 24" <br />OF STAGGERED 10d COMMON WIRE NAILS <br />OF STAGGERED 30d COMMON WIRE NAILS <br />STAGGERED 30d COMMON WIRE NAILS <br />TRUSSES FROM EA. <br />__ E <br />ES AND 12" O.C. FIELD <br />0/C w/ (2) 16d <br />(D = 0.148", L = 3") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />END TYP. TOP & <br />JACK TRUSS <br />TOENAILS @ EA. END <br />NOTES: <br />BOTTOM ATTACHED <br />' ==r<r SEE PLAN FOR <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA, x 51/2" LAG SCREWS OR EQUAL <br />w/ (2)16d TOENAILS <br />_ ff ==:,_CONNECTION <br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) -- <br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL 2x4'7" ON <br />OF THE LAST LAMINATION (SPACE AS SHOWN R 3 FO-PBLOCKING, TOP PANEL <br />BLOCKINNG, FASTEN <br />N WITH 2x4 BLOCKING W/ , .. <br />b 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION 10dx3" @ 4" 0/C (2)12d TOENAILS <br />EXT. WALL CONN. @ COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />NON - LOAD BEARING LOCATION B.U.C. SAME NUMBER OF ROWS SAME SPACING) <br />) SECTION <br />131 SEE TYP. WALL SECTION FOR SCALE: 3/4"=V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 9 <br />ADDITIONAL INFORMATION. <br />I <br />N <br />G 45• <br />i <br />MINIMUM 2x <br />Q CROSS BRACING <br />(SEE PLAN FOR <br />LOCATIONS) <br />(2)16d PER <br />JOINT <br />LO <br />O <br />S CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />00 00 CROSS BRACING DETAIL J <br />z SCALE: N.T.S. <br />S5 <br />2"x4" OUTLOOKER @ 24" - <br />O.C. W/ (2)10d PER JOINT <br />TOENAIL- <br />W/ (2)16d <br />NAILS <br />ALTERNATE NON -DROP <br />GABLE END DETAIL <br />SCALE: N.T.S. <br />1 GABLE TRUSS <br />o � <br />"L" BRACE W/ 10d @ 4" O.C. <br />12 (SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />6.9 MAX. <br />E S5 <br />`v <br />c <br />aNi <br />li <br />6 <br />S5 <br />• <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />PRE-ENGINEERE <br />WOOD TRUSSES <br />S5 SCALE: N.T.S. S5 <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES 6" OVERLAP <br />`MINIMUM (2)16d PER JOINT `-MINIMUM 2x4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL rM <br />SCALE: N.T.S. S5 <br />"L" BRACE W/ 10d @ 4" 0/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />a <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)10d <br />WOOD TRUSSES TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />0 <br />z <br />w <br />BRACING wl (3)10d x 3" AT <br />• EACH CONN. @ 24" O/C <br />OKT <br />1/4"x1 1/2" SDS SIMPSON HGAw/ (4) MOISTURE BARRIER <br />SCREWS TO <br />BLOCKING & (4)1/4"x2 3/4" BOND BEAM <br />TITEN TO CMU <br />MASONRY WALL <br />2x4 BLOCKING 2x4 "T' BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL <br />5 <br />SCALE: N.T.S. S5 <br />2x4 "T' BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ NAILS @ 4" O.C� <br />TYPICAL/KCAL <br />GABLE TRUSS WEB --/ <br />SINGLE "L" BRACING DETAIL s <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE -� <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DIET. J/S5 r CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. <br />� <br />Illlil�l <br />i <br />s <br />ARCHITECTURAL FINISH NOTE: <br />EXT. WALL CONN. NON -LOAD <br />BEARING LOCATIO (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />010" - T-0" <br />3'-0" - 61-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1l4" x1 11T SDS <br />SCREWS TO TRUSS & (4) 14'XY SDS SCREWS <br />TO PLATES (TYP.) <br />GABLE TRUSS <br />'--STUDS @ 16" O.C. <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />HIP FRAMING REFERENCE PLAN <br />E <br />S5 <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2) 7' BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />9� <br />/TOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />Z M <br />z® <br />z <br />a <br />U, z <br />V) (D <br />Cz <br />(1) <br />u, <br />4 -J w <br />•V o <br />Ow <br />U <br />w E <br />mo <br />� rN i <br />(h <br />¢ rn <br />n}� <br />14 <br />U.) <br />�¢ o <br />N .D <br />N <br />Z il- f+ <br />Uv <br />WuAl a �rn� 3 <br />Z Oo z <br />1 it <br />,lllp��! <br />r� <br />'• WN'W. S M �•❑l7r <br />� <br />•; cs <br />� <br />cu <br />"R O F E S S�0 <br />To the best of the Engineers knowledge, informsUon and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residentlal 6th Edition. Engineers signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W Cypress St, Suite 200 � Tampa, FL 33607 <br />www.LennarTampa.com <br />9 <br />�00 <br />� U <br />� W <br />gh <br />� J <br />U. <br />L <br />g <br />00o"'%% <br />VJ <br />�z <br />a� <br />Q <br />w <br />z <br />¢ <br />o <br />0g <br />0 <br />ZW <br />^ <br />1� <br />t� � uJ <br />Z <br />J <br />Ln <br />r-,1 <br />LLj <br />Z <br />Z <br />Q `� <br />Svg <br />c) <br />CIOZ <br />O <br />0 <br />06 <br />J <br />tj <br />= <br />8 <br />.--i <br />a <br />cn <br />s <br />SCALE : AS NOTED <br />DATE : 10/4/2018 <br />TECH: JMUROSKI <br />VERSION NO 4mO <br />SHEET NO. <br />S5 <br />