My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2980 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2980 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:01:08 AM
Creation date
2/19/2025 10:29:11 AM
Metadata
Fields
Template:
Building Plans
Street #
2980
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20747
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIMPSON <br />Strong -Tie <br />March 20, 2018 <br />Re: Wood Construction Connector Compliance for 2015 International Codes & 2017 Florida Codes <br />To Whom It May Concern <br />Section 2303.5 of the 2015 International Building Code (IBC) and 2017 Florida Building Code (FBC) specifies that <br />joist hangars shall be tested per ASTM D7147 Tesfing and Estebishing Loads of Joist Hangers. Previous versions of <br />the IBC and FBC required testing to comply with ASTM D1761 Test Method for Mechanical Fasteners in Wood. Both <br />methods determine a connector's allowable bad as the lowest of the following: <br />1. Lowest ultimate of three tests (or average of 6) with a safety factor of 3 <br />2. Average load at 1/8-inch deflection <br />3. Coiculations per American Wood Council National Design Specification for Wood Construction (NDS) <br />The primary changes 1n ASTM D7147 are requirements to measure properties of the tested materials, such as steel <br />strength, fastener strength, and wood specific gravity. The tested ultimate loads must be adjusted when tested <br />material properties exceed to specified properties. <br />ICC Evaluation Services (ICC-ES) revised AC13 Acceptance Cntarre fir Joist Harpers and Similar Devices in <br />October 201e to incorporate a methodology to evaluate products to the 20151-Codes. Simpson Strong -Tie is working <br />on re-evaluating wood construction connector bads to the new standard to update our product evaluation reports to <br />the 2015 I -Codes. As soon as the update evaluation reports are completed, we will apply for Florida Product <br />Approvals. <br />However, reevaluating a large number of products will take time. While manufacturers work with product certification <br />agencies to update their wood connector evaluation reports, we recommend that building departments under the <br />2015 ]-Codes and 2017 Florida Codes continue to accept code reports showing compliance to the 2012 and 2014 <br />editions, respectively, until July 2018, <br />The information in this letter is valid until 6/30/2018 when it will be re-evaluated by Simpson Strong -Tie. Please visit <br />www.stronotie.com for additional pertinent information. If you have questions or reed further assistance regarding <br />this matter, please corded the Simpson Strong -Tie Engineering Department at 800.999.5099. <br />Sincerely, <br />SIMPSON STRONG -TIE COMPANY INC. <br />16P4 <br />Keith Cullum, P.E., LEED AP dwfBDW <br />Engineer, Southeast U.S. Branch <br />Page 1 of 1 <br />Simpson Strong-Tde Company Inc. 2221 CountryLsno McKhM, TX 75009 Phom: 972.542.0320 Fax 972.542.4139 inaii.}$g9agt,9om <br />TO <br />A23 <br />FL10446.2 <br />mill <br />11adown WE <br />ESR-2608 <br />A3 <br />FL17244.1 <br />ESR-3455 <br />M0210.2 <br />FL17232.3 <br />ESR-3445 <br />HU210.2 <br />FL10856.4 <br />ESR-2549 <br />HD212-2 <br />FL17232.3 <br />ESR-3446 <br />HU212-2 <br />FL10856.4 <br />ESR-2649 <br />HD216 <br />FL17232.3 <br />ESR-3445 <br />HU216 <br />FL10858.5 <br />ESR-2549 <br />HD216.3 <br />FL17232.3 <br />ESR-3445 <br />HU216.3 <br />FL10858.1 <br />ESR-2549 <br />HD26 <br />FL17232.2 <br />ESR-3445 <br />HU28 <br />FL10868.3 <br />ESR-2549 <br />HD28.2 <br />FL17232.3 <br />ESR-3445 <br />HU28.2 <br />FL10856.4 <br />ESR-2549 <br />HD410 <br />FL17232.4 <br />ESR-3445 <br />HU410 <br />FL10856.9 <br />ESR-2549 <br />H0412 <br />FL17232.4 <br />ESR-3445 <br />HU412 <br />FL108W.9 <br />ESR-2549 <br />HD810 <br />FL17232.4 <br />ESR-3445 <br />HU610 <br />FL10856.10 <br />ESR-2549 <br />HD0410 <br />FL17241.7 <br />ESR-3444 <br />HUC0410 <br />FL11468.11 <br />S1M200804 <br />HGA10 <br />FL17699.1 <br />Evaluation Report <br />MGA10KT <br />FL11470.4 <br />SIM200803 <br />HGAM10 <br />FL17699.1 <br />Evaluation Report <br />HGAM10KT <br />FL11470.4 <br />SIM200803 <br />HHCP2 <br />FL17238.7 <br />ESR-3448 <br />HCP2 <br />F1.10447.2 <br />ESR-2551 <br />HTA18 <br />FL17880.4 <br />Evaluation Report <br />HETA18 <br />FL11473.5 <br />SIM200802 <br />HTA20.18 <br />FL17680.4 <br />Evaluation Report <br />HETA20 <br />FL11473.5 <br />SIM200802 <br />HTT16 <br />FL17324.2 <br />Evaluation Repot <br />HTT16 <br />FL11496.1 <br />ES-0130 <br />HTT45 <br />FL17324.2 <br />Evaluation Report <br />HTT22 <br />FL11496.1 <br />ES-0130 <br />HTW18 <br />FL17244.8 <br />FSR-3455 <br />HTS16 <br />FL10456.22 <br />ESR-2613 <br />HTW20 <br />FL17244.8 <br />ESR-3455 <br />HTS20 <br />FL10456.23 <br />ESR-2613 <br />HTW24 <br />FL17244.8 <br />ESR-3455 <br />HTS24 <br />FL10456.24 <br />ESR-2613 <br />HTW30 <br />FL17244.8 <br />ESR-3455 <br />HTS30 <br />FL10456.26 <br />ESR-2613 <br />HTWM16 <br />FL6223.2 <br />Evaluation Report <br />HTSM16 <br />FL11473.11 <br />SIM200802 <br />HTWM20 <br />FLSM.2 <br />Evaluation Report <br />HTSM20 <br />FL11473.11 <br />SIM200802 <br />HUGT2 <br />FL6223.3 <br />Evaluation Report <br />HGT2 <br />FL10456.18 <br />ESR-2613 <br />HUGT3 <br />FL6223.3 <br />Evaluation Report <br />HGT3 <br />FL10458.19 <br />ESR-2613 <br />HUS210.2 <br />FL17232.6 <br />ESR-3445 <br />HUS210-2 <br />FL10656-R4 <br />ESR-2649 <br />HUS212-2 <br />FL17232.6 <br />ESR-3445 <br />HUS212-2 <br />FL10856.11 <br />ESR-2549 <br />HUS28 <br />FL17232.6 <br />ESR-3445 <br />HUS28 <br />FL10858.11 <br />ESR-2549 <br />HUS28 <br />FL17232.6 <br />ESR-3445 <br />HUS28 <br />FL10856,11 <br />ESR-2649 <br />HUS28-2 <br />FL17232.6 <br />ESR-3445 <br />HUS28-2 <br />FL10856.11 <br />ESR-2549 <br />JL24 <br />FL17232.7 <br />ESR-3445 <br />LU24 <br />F00655.103 <br />ESR-2549 <br />JL26 <br />FL17232.7 <br />ESR-3445 <br />LU26 <br />FL10655.104 <br />ESR-2549 <br />JUS210.2 <br />FL17232.11 <br />ESR-3445 <br />LUS210.2 <br />FL10655.107 <br />ESR-2549 <br />JUS24 <br />FL17232.10 <br />ESR-3445 <br />LUS24 <br />FL10855.109 <br />ESR-2549 <br />JUS26 <br />FL17232.11 <br />ESR 3445 <br />LUS26 <br />FL10655.111 <br />ESR-2549 <br />JUS26.2 <br />FL17232.11 <br />ESR-3445 <br />LUS28.2 <br />FL10555.112 <br />ESR-2549 <br />JUS28 <br />FL17232.11 <br />ESR-3445 <br />LUS28 <br />FL10655.113 <br />ESR-2549 <br />JUS46 <br />FL17232.11 <br />ESR-3445 <br />LUS46 <br />FL10855.118 <br />ESR-2649 <br />II <br />FL17241.15 <br />ESR-3444 <br />LEGS <br />FL10687.71 <br />ESR-2615 <br />KST260 <br />FL17244A5 <br />ESR-3455 <br />MST60 <br />FL10852.7 <br />ESR-2105 <br />LSTA12 <br />FL17244.18 <br />ESR-3455 <br />LSTA12 <br />FL10852.4 <br />ESR-2105 <br />LSTA16 <br />FL17244.18 <br />ESR-3455 <br />LSTA15 <br />FL10852.4 <br />ESR-2105 <br />LSTA18 <br />FL17244.18 <br />ESR-3466 <br />LSTA18 <br />FLIDSW 4 <br />ESR-2105 <br />LSTA24 <br />FL17244.18 <br />ESR-3455 <br />LSTA24 <br />FL10852.4 <br />ESR-2105 <br />LSTA30 <br />F117244.18 <br />ESR-3455 <br />LSTA30 <br />FL10852.4 <br />ESR-2105 <br />LSTA36 <br />FL17244.18 <br />ESR-3455 <br />LSTA36 <br />FL10852.5 <br />ESR-2105 <br />LTS19 <br />FL17219.2 <br />ER-0200 <br />LTT19 <br />FL11498.3 <br />ER-130 <br />LTS20B <br />FL17219.2 <br />ER-0200 <br />LTT20B <br />FL11496.3 <br />ER-130 <br />LTTI31 <br />FL17219.2 <br />ER-0200 <br />LTTI31 <br />F111498.3 <br />ER-130 <br />LTW12 <br />FL17244.8 <br />ESR-3455 <br />LTS12 <br />FL10455.29 <br />ESR-2613 <br />LUGT2 <br />FL17240.2 <br />ESR-3447 <br />LGT2 <br />FL11470.7 <br />SIM200803 <br />MP3 <br />FL17244.22 <br />ESR-3455 <br />LS30 <br />FL10446.15 <br />ESR-28M <br />MP34 <br />FL17244.23 <br />ESR-3456 <br />A34 <br />FL10448.3 <br />ESR-28M <br />MPI <br />FL17244.24 <br />ESR-3455 <br />LTP4 <br />FL10446.19 <br />ESR-2608 <br />MP5 <br />FL17244.22 <br />ESR-3455 <br />LS50 <br />FL10448.18 <br />ESR-2005 <br />MPH3516 <br />FL17240.3 <br />ESR-3447 <br />WM1416 <br />FL10867.88 <br />ESR-2615 <br />MSTA12 <br />FL17244.18 <br />ESR-3455 <br />MSTA12 <br />FL10852.8 <br />ESR-2105 <br />MSTAIS <br />FL17244.18 <br />ESR-3465 <br />MSTA15 <br />FL10852.8 <br />ESR-2105 <br />MSTA18 <br />FL17244.18 <br />ESR-3455 <br />MSTA18 <br />FL10852.9 <br />ESR-2105 <br />MSTA24 <br />FL17244.18 <br />ESR-3455 <br />MSTA24 <br />FL10852.9 <br />ESR-2106 <br />MSTA38 <br />FL17244.18 <br />ESR-3455 <br />MSTA36 <br />FL10852.9 <br />ESR-2105 <br />MSTC40 <br />FL17244.26 <br />ESR-3455 <br />MSTC40 <br />FL10852.11 <br />ESR-2105 <br />MSTC52 <br />FL17244.26 <br />ESR-3455 <br />MSTC52 <br />FL10852.11 <br />ESR-2105 <br />MTW12 <br />FL17244.8 <br />ESR-3455 <br />MTS12 <br />FL10458.33 <br />ESR-2613 <br />MTW16 <br />FL17244.8 <br />ESR-3455 <br />MTS16 <br />FL10456.34 <br />ESR-2613 <br />MTW18 <br />FL17244.8 <br />ESR-3455 <br />MTS18 <br />FL10456.35 <br />ESR-2613 <br />MTW20 <br />FL17244.8 <br />ESR-3455 <br />MTS20 <br />FL10456.36 <br />ESR-2613 <br />MUGT15 <br />FL17240.5 <br />ESR-3447 <br />MGT <br />FL11470.9 <br />SIM200803 <br />NFM35X12 <br />FL578.2 <br />Evaluation Report <br />MBHA3.58/11.25 <br />FL13904.6 <br />ESR-2618 <br />NFM35XIBU <br />FL578.3 <br />Evaluation Report <br />MBHA3.56/18 <br />F113904.6 <br />ESR-2618 <br />PAU44 <br />FL17239.13 <br />ESR-3449 <br />HOU2-SD82.5 <br />FL10441.4 <br />ESR-2330 <br />PAU66 <br />FL17239.13 <br />ESR-3449 <br />GLTV3.516 <br />FL10667.8 <br />ESR-2615 <br />PHD2A <br />FL17219.3 <br />ER-0200 <br />FGTR <br />FL11473.2 <br />SIM200802 <br />PHXU3516 <br />FL17241.20 <br />ESR-3444 <br />CS16 <br />FL108W.1 <br />ESR-2105 <br />RFUS <br />FL6223.5 <br />Evaluation Report <br />H1 <br />FL104W.5 <br />ESR-2613 <br />RS150 <br />FL17244.27 <br />ESR-3455 <br />H10 <br />FL10456.6 <br />ESR-2613 <br />RT15 <br />FL17236.3 <br />ESR-3448 <br />H10.2 <br />FL10456.7 <br />ESR-2613 <br />RT16.2 <br />FL17236.2 <br />ESR-3448 <br />H10A <br />FL10456.6 <br />ESR-2813 <br />RT18A <br />FL17236.2 <br />ESR-3448 <br />H3 <br />FL10456.13 <br />ESR-2613 <br />RT3A <br />FL17236.3 <br />ESR-3448 <br />H4 <br />FL10456.14 <br />ESR-2613 <br />RT4 <br />FL17238.3 <br />ESR-3448 <br />H5 <br />FL10458.15 <br />ESR-2613 <br />RTS <br />FL17236.3 <br />ESR-3448 <br />H2.5 <br />FL10456.11 <br />ESR-2613 <br />RT7 <br />FL17236.3 <br />ESR-3448 <br />H2.5A <br />FL10456.12 <br />ESR-2613 <br />RT7A <br />FL17236.3 <br />ESR-3448 <br />H8 <br />FL11470.3 <br />SIM200803 <br />RTBA <br />FL172W.3 <br />ESR-3448 <br />SP1 <br />FL10456.41 <br />ESR-2613 <br />SPT22 <br />FL17244.30 <br />ESR-3455 <br />SP2 <br />FL10456.42 <br />ESR-2613 <br />SPT24 <br />FL17244.31 <br />ESR-3455 <br />SP4 <br />FL10456.43 <br />ESR-2613 <br />SPT4 <br />FL17244.32 <br />ESR-3455 <br />SP8 <br />FL10458.44 <br />ESR-2613 <br />SPTB <br />FL17244.32 <br />ESR-3455 <br />SPB <br />FL10456.45 <br />ESR-2613 <br />SPI <br />FL17244.32 <br />ESR-3455 <br />SPH4 <br />FL10456.46 <br />ESR-2613 <br />SPTH4 <br />FL17244.32 <br />FSR-3455 <br />SPHB <br />FL104W.47 <br />ESR-2613 <br />SPTH6 <br />FL17244.32 <br />ESR-3455 <br />SPHB <br />FL10456.48 <br />ESR-2613 <br />SPTHB <br />FL17244.32 <br />ESR-3455 <br />U24 <br />F00655.141 <br />ESR-2549 <br />SUH24 <br />FL17232.13 <br />ESR-3445 <br />HHUS28.2 <br />FL10855.3 <br />ESR-2549 <br />THD28 <br />FL17232.16 <br />ESR-3445 <br />HHUS410 <br />FL10655.4 <br />ESR-2549 <br />THD28-2 <br />FL17232.16 <br />ESR-3445 <br />HGUS5.25/12 <br />FL11468.11 <br />SIM200804 <br />THD410 <br />FL17232.16 <br />ESR-3445 <br />HGUS414 <br />FL11468.10 <br />SIM200OD4 <br />THD412 <br />FL17232.16 <br />ESR-3445 <br />HD08-SDS9 <br />FL10441.1 <br />ESR-2330 <br />THD612 <br />FL17232.16 <br />ESR-3446 <br />MSTAM24 <br />FL11473.19 <br />SIM200802 <br />THDH414 <br />FL17232.17 <br />ESR-3445 <br />MSTAM36 <br />FL11473.19 <br />SIM200802 <br />UGTS3F <br />FL2033.1 <br />Evaluation Report <br />MSTCM40 <br />FL11473.19 <br />SIM200802 <br />UPHDB <br />FL17219.5 <br />ER-0200 <br />HHETA20 <br />FL11473.9 <br />SIM2DOW2 <br />LGT3SDS2.5 <br />FL11470.7 <br />SIM200803 <br />- <br />- <br />- <br />LGUM28-2 <br />FL71473.12 <br />SIM200802 <br />PRODUCT APPROVAL SPECIFICATION SHEET (2018) March 28, 2018 <br />As required by Florida Statute 553.842 and Florida Administrative Code 98-72, please provide the information and approval numbers on the building components listed below If they will be utilized on die <br />construction project for 1Xch you are applying for a building permit. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed <br />products. <br />CategorylSubcategory <br />Manufacturer <br />Product Description <br />Approval Number(s) <br />Test Pressures <br />1. EXTERIOR DOORS <br />A. SWINGING <br />ThennaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461,1 <br />+67.0/$7.0 psf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461.6 <br />+67.0/-67.0 psf <br />ThennaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />F1.20481.9 <br />+87.0/-87.0 psf <br />ThermsTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461.14 <br />+67.0/-67.0 psf <br />ThemnaTru <br />Classic -Craft and Benchmark <br />FL15225.1 <br />+87.01-67.0 psf <br />ThennaTru <br />Smooth -Star and Benchmark <br />FL15225.5 <br />+67.0/-67.0 psf <br />ThennaTru <br />FlberClassic, Smoothstar, ClassicCraft, Rustic <br />FL7640.1 <br />+67.0/-67.0 psf <br />B. SLIDING <br />MI Wndows and Doors <br />Series 420 <br />FL15332.1 - FL15332.5 <br />+40.0/40.0 psf <br />PGT <br />Series 5570 <br />FL251.10 <br />C. SECTIONAL <br />Clopsy Building Products <br />Residential WndCode Doors W5 (8X7) <br />FL15279.37 <br />+30.0/-32.0 psf <br />Clopay Building Products <br />Residential WndCode Doors W5 (18X7) <br />FL15279.53 <br />+30.01-30.0 psf <br />Clopsy Building Products <br />Residential WndCode Doors W6 (8X7) <br />FL15279.85 <br />+38.0142.0 psf <br />Clopsy Building Products <br />Residential WndCode Doors W6 (16X7) <br />FL15279.102 <br />+37.0141.0 psf <br />D. METAL LOUVERED ORS <br />Curries Division of AADG, Inc <br />607,707,727,747,and 847 Single & Pairs of Doors <br />FL11537.1 <br />N/A (see tint sht) <br />2. WNDOWS <br />A. SINGLE HUNG <br />MI Windows and Doors <br />Series 185 <br />FL17499.2 <br />+50.0/-55.0 par <br />PGT <br />Series 5500 <br />FL239.7 <br />B. HORIZONTAL SLIDER <br />MI Wndows and Doors <br />Series 188 <br />FL1W51.1 <br />+40.0/-50.0 psf <br />C. FIXED <br />MI Windows and Doors <br />Seder 185 <br />FL15349.1 <br />+40.0140.0 per <br />PGT <br />Series 5520 <br />FL243.9 <br />D. MULLION <br />MI Wndows and Doors <br />Series 5764 <br />FL15353.2 <br />WA <br />PGT <br />Series 5500 <br />FL261.1 <br />N/A <br />E. OTHER <br />3. PANEL WALL <br />A. SIDING <br />James Hardie Building Prod. <br />Camplank Lap Siding and HardiePlank Lap Siding <br />FI I3192.1 - FL13t92.2 <br />N/A <br />B. SOFFITS <br />Alside <br />Solid and Vented Soffit <br />FL15272.1 - FL15272.2 <br />+70.0/-70.0 psf <br />C. OTHER <br />4. ROOFING PRODUCTS <br />A. ASPHALT SHINGLES <br />GAF <br />3 Tab, Dimensional <br />FL10124.1 <br />N/A <br />B. UNDERLAYMENTS <br />Tamko <br />151b Felt Underlayment <br />FL12328.6 <br />N/A <br />C. ROOFING FASTENERS <br />NOT USED <br />D. ROOF VENTILATORS <br />Thompson Arch Metal Comp. <br />OR Ridge Vents <br />FL16918.1- FL16918.4 <br />NIA <br />Florida Metal Products, Inc <br />Vent RVIO <br />FL21580.3 <br />N/A <br />Lomanoo, Inc <br />DA4 Exahust Vent <br />FL17202.1 <br />NIA <br />E. ROOFING TILES <br />Boral Tile <br />Villa 900 <br />FL7849.27 - FL7849.28 <br />N/A <br />Boral Tile <br />Saxony 9W <br />FL7849.16 - FL7849.20 <br />WA <br />F. METAL ROOF <br />Gulf Coast Supply & Manufacturing, LLC <br />0.032' Aluminum Gulf -ok 16" wide roof panel <br />FL11651.2 R3 <br />N/A <br />5. SHUTTERS <br />A. STORM PANELS <br />Global Protection Products <br />Galvanized Steel Storm Panels <br />FL15076.1 - FL15076.2 <br />N/A <br />All American Shutters & Glass <br />Galvanized Steel Storm Panels <br />FL17889.1 <br />N/A <br />6. STRUCTURAL <br />COMPONENTS <br />A. WOOD CONNECTORS/ <br />USP Structural Conn. <br />see chart <br />ANCHORS <br />Simpson Strag-Tie <br />see chart <br />B. TRUSS PLATES <br />ITW Building Components <br />Alpine Truss Plates <br />FL1999A - FL1999.4 <br />N/A <br />MTek Industries, Inc. <br />Truss Plates <br />FL2197.1 - FL2197.5 <br />N/A <br />C. ENGINEERED LUMBER <br />Weyerhaeuser <br />Rim Board, LVL, PSL, LSL <br />FL6527.1 - FL6527.5 <br />NIA <br />D. MATERIAL <br />Cast -Crete Corp. <br />High Strength Concrete Untels <br />FL158.1 <br />NIA <br />Commercial Concrete Products, Inc. <br />High Strength Concrete Untels <br />FL1774 <br />NIA <br />The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the <br />jobsits; 1) copy of the product approval, 2) the performance Characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I <br />understand these products may have to be removed if approval cannot be demonstrated during inspection. <br />APPLICANT SIGNATURE <br />DATE <br />N <br />N <br />Cn <br />U <br />2 <br />0 <br />N <br />C <br />Ca <br />O <br />- <br />.CD <br />U <br />C <br />O <br />O <br />O <br />O <br />W <br />O <br />LL <br />E <br />M <br />-0 <br />O <br />L <br />. - <br />CO <br />W <br />W <br />p � <br />SHEEP N0. <br />PA 1,0. <br />
The URL can be used to link to this page
Your browser does not support the video tag.