Laserfiche WebLink
Ni <br />!0- <br />rb <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94—/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />upper to lights & outlets <br />upper to 20 amp tits <br />copper to WH <br />copper to Dryer <br />I Afu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying With UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PTF <br />DUPLEX OUTLET ABOVE COUNTER <br />w.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />• �4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />WP DISC. <br />GFI H.I <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn man e0cr1c, <br />TRACK LIGHT <br />" ' \ <br />L <br />dM <br />GFI @ 44" <br />�--� <br />FLUORESCENT LIGHT FIXTURE <br />ROUGH -IN FOR \ <br />I <br />A.F.F. <br />=4 <br />O <br />EXHAUST FAN <br />\ OPT. CLG. FAN/ <br />\ LIGHT PRE -WIRE <br />I <br />I <br />GFI <br />GAF <br />Oi <br />EXHAUST FAN/LIGHT COMBINATION <br />` <br />i <br />GFI <br />2 CAR GARAGE <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />70 <br />I <br />I <br />CH <br />CHIMES (OPTIONAL) <br />OWNER'S SUITE <br />WI.I.C. <br />I <br />PUSH BUTTON SWITCH (OPTIONAL) <br />I <br />I <br />PUSH BUTTON SWITCH - DOOR BELL <br />I <br />I <br />I <br />O <br />SD <br />SMOKE DETECTOR <br />-�- <br />j <br />W.H. VERIFY LOCATION <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />00- GFI <br />------j <br />ELECTRICAL PANEL <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />RECEPT. <br />FOR ALARM <br />VERIFY METER <br />® <br />TELEVISION (OPTIONAL) <br />SYSTEM <br />LOCATION WITH <br />BUILDER <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />owl_ <br />ELECTRIC PANEL <br />_M..I <br />DISCONNECT SWITCH <br />4Z� <br />G�J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MIOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT, CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4 "=1'-0" <br />Z M <br />Z <br />Q <br />d <br />U) z <br />V) 0 <br />Cl <br />}, cn <br />w <br />(DOUo <br />�U — <br />pLL, <br />C_- <br />(tN <br />v U C) <br />W <br />� <br />r- <br />m N <br />Qp1M-MM <br />' :,: - <br />g @ N <br />UlJ_00 <br />n <br />Qrn <br />tnv <br />9i Q c <br />B D. <br />N �O <br />V� o <br />U Z ID Z <br />) "ass" <br />Pasa 5 E� <br />oOC <br />W <br />ZOdam' o <br />Islas <br />$6 m� <br />LLU) 2 <br />ZaN <br />o o <br />WWW.FDSENG.COM U <br />00 <br />0 <br />CV <br />M <br />CV <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />$ <br />W <br />Za <br />4Z <br />�ZW <br />pp <br />L <br />< <br />W <br />a. <br />Z <br />LU <br />.J <br />LU <br />W <br />0� <br />T� <br />V <br />= <br />T <br />O <br />LLB <br />Z <br />d' <br />a,Z�UJ- <br />W S-- <br />Z <br />J <br />Ln <br />W <br />&!i <br />Nz8 <br />W <br />Q <br />t—F <br />N <br />Z <br />Z <br />Z <br />tj <br />$ <br />0 <br />00 <br />g <br />= <br />a f <br />7-4a <br />to <br />s <br />SCALE : AS NOTED <br />DATE : 10/29/2018 <br />TECH: MJAMES <br />VERSION NO. 4vO <br />SHEET NO. <br />4.0 <br />