Laserfiche WebLink
a`> <br />2 <br />LO <br />CD <br />0 <br />0 <br />CV <br />00 <br />00 <br />m <br />t <br />00 <br />a <br />E <br />0 <br />x <br />00 <br />w <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />� G F I <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4, � <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />T� <br />TELEVISION (OPTIONAL) <br />T� 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />PM <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />_I <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />10 #14 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />No #12 Copper to 20 amp ckts <br />#10-2 copper to WH <br />10 #10.3 copper to Dryer <br />METER <br />MO2I0 <br />or <br />4!0 SER Alu <br />200 amp <br />150 amp <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />VERIFY METER LOCATION <br />MAIN ELECTRICAL PLAN <br />SCALE: %4"= V-0" <br />0 V <br />Z M <br />0 <br />o <br />zN <br />z� <br />Q <br />(D rZ <br />U) Z <br />CVn)' (D <br />Q) C <br />LU <br />�V — <br />QLU <br />c <br />o <br />r <br />Cl)Nco <br />U <br />0 <br />m <br />LU <br />c ) <br />OS <br />U <br />_ON <br />000� <br />Lp <br />ao <br />0 co <br />Q C" <br />34 <br />0 <br />� o <br />rn QAl <br />I <br />BID. <br />N�c <br />'t <br />N N <br />`S O <br />U 4D LUM mz w z <br />C <br />�LLo.s ua w <br />Uj <br />LU a L <br />Z �0�Q <br />U) o t, <br />LLns <br />Z a � mom' <br />W N¢C14 A <br />o v 3 O <br />WWW.FDSENG.COM <br />00 <br />0 <br />CV <br />CV <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />oz <br />0 <br />C'o <br />Z <br />Z>Z <br />W Q <br />�zoCZ <br />zUZ� <br />0 W Z <br />Re <br />a�J <br />00 <br />z <br />OU W LL N <br />Lu <br />to <br />Q <br />L <br />zz <br />> OU <br />N <br />> <br />J <br />Z <br />�, <br />V <br />a <br />/Q^ <br />4 <br />Z <br />U <br />`J <br />w <br />LU � <br />opz <br />J <br />W <br />1.-0 <br />0, <br /><UA <br />J <br />l , <br />W W Q <br />ce <br />W <br />Z <br />Z <br />T� <br />50�0 <br />r(30� <br />W <br />J <br />Li! <br />W <br />) (9 0 <br />U <br />r-i <br />lJJ <br />84 <br />00 <br />M <br />2:a <br />Q <br />Z <br />�cez <br />Z <br />Ra Zo <br />ao <br />C° <br />Z <br />J Q! <br />a <br />0 <br />oo <br />g <br />= <br />f <br />rn <br />T-'I <br />a <br />U0 <br />s <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: MJAMES <br />VERSION N0. 4nO <br />SHEET NO. <br />4.0 <br />Ifi�l�flFa1l19 f�lh9i�r(ll�ll�li l �lA1l���w���� ��� ��Mill <br />