My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2995 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2995 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:19:04 AM
Creation date
2/19/2025 10:29:56 AM
Metadata
Fields
Template:
Building Plans
Street #
2995
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20517
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TnM — — <br />11-011 <br />14'-0" RIDGE VENT <br />EXTENDED <br />OVERHANG TO <br />BE CENTERED - <br />ON DOOR <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />------------------ <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />12 <br />T-O" RIDGE VENT <br />12 12 <br />- ,IMF-Ls-L�.-_=..1. r + =�-= 4 6 ��.Ir V F - <br />�.rur. <br />5 <br />REAR ELEVATION - B1 <br />1" x 9" SMOOTH <br />TEXTURED <br />FREEZE BAND <br />SHINGLES. ROOF <br />- INSTALLED AS PER MANUF <br />f -T` �t� I 'Y �r� 1 1 � 1 I t- l I '-9•�`I �.�T. <br />--_ a _..____' _� J_ — ..4 �. 1 , _ — — _ _. SPECIFICATIONS <br />I I I r t_mm I <br />- — <br />T.O.M. <br />1' 0" 1' 0" <br />- — — — — — — — — —----------------------- HDRHGT. <br />------------------------------------ <br />----- --- --------------------------- <br />4. <br />TEXTURED <br />0-41 CEMENTICIOUS <br />2'-0" FINISH ON C.M.U. <br />(TYP) TEXTURED o <br />CEMENTICIOUS Q0 co <br />FINISH ON C.M.U. <br />(TYP.) <br />------------ ------------------------------------------- <br />+3" SMOOTH <br />-TEXTURED <br />BAND <br />LEFT ELEVATION - B1 <br />: 1/4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventileted.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SO. FT. <br />CD V- <br />0 <br />z� <br />z�® <br />a <br />Q) <br />4--i w <br />•V — <br />Ow <br />V) <br />� <br />U <br />w <br />M <br />C) <br />c <br />t° <br />ai a c <br />BID. <br />N <br />fnF�. <br />a <br />: � <br />VaCL^ <br />10W <br />z 0��a <br />� s <br />is N M i <br />U W <br />A%<. a <br />,`001lllllA/lyj <br />c'C, ..E,b.co <br />•�•. 5� �' <br />Y O <br />AR O F S S\O \���\\` <br />� <br />E <br />���'ff�lli11114t11"�� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential eth Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />o <br />50 <br />z0. <br />E <br />z <br />O <br />U�oo <br />W <br />o� <br />UJ <br />LLJ <br />LU <br />Q <br />0 <br />U <br />= <br />z <br />Q <br />W <br />W1 <br />LL <br />z <br />U~ 4O <br />V <br />y <br />W <br />Z <br />J <br />Ln <br />Lli <br />z <br />Ila <br />Q <br />Fm8 <br />M <br />Q <br />z <br />z <br />� <br />z <br />��g <br />co <br />O <br />06 <br />g <br />= <br />,� <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAMES <br />VERSION NO. 4nO <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.