g <br />r` I <br />s <br />of <br />a <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA1 <br />200 AMP <br />MAIN <br />0 <br />200 amp <br />150 amp <br />copper to ligms a outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />LROUNDING <br />BONDING <br />WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />WP DISC. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />GFI H. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an \ IT T — GFI U -- GFI <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and AC PAD \ _ <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. R NG <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed \ �- <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing \ PENDANT AS <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the PER SPECS i Et ��� <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing — _ I U.C. SNVITt✓h <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY PA f0 <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />Lph SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />j4 FOUR-WAY SWITCH <br />�R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />--..—I FOR t)tSP St—+— <br />„� \ ' &INK I DI - <br />/CAF E` <br />- -- - <br />\ / \ —GFI L-- J -- --1 <br />I GFI �— <br />U.C. OUTLET \ <br />U.C. OUTLET <br />FOR DW <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />FAM& R M \ <br />/ 4 <br />I <br />C.M <br />WALL MOUNTED LIGHT FIXTURE <br />(� RECESSED LIGHT FIXTURE <br />�J LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS (SD <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />49 PUSH BUTTON SWITCH (OPTIONAL) <br />F9 PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />owl ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />--L <br />OPT. I <br />REF. <br />I <br />\ <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />YGHT PRE-WIRF� <br />BEDROOM 2\\� <br />/ E <br />ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I A E <br />BED OOM l <br />� 1 <br />\ ,I CSD <br />C.M <br />— — — — — — — — — — — — — — S.D. <br />Pdb <br />OPT. <br />D. <br />-I --- --- -- -- <br />r � <br />r <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ I <br />\ LIGHT PRE -WIRE <br />12 <br />HER' -- - W I.C. <br />OWNER'S SUITE - <br />� A� , , <br />- , <br />1 <br />I I <br />I <br />-----------J <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />ROUGH -IN FOR <br />�— OPT. CLG. FAN/ <br />B EfiRCOOLIGHT PRE -WIRE <br />M4 <br />GFI <br />GFI @ 44" <br />A.F.F. <br />` r------------ <br />) � I <br />I l l I I <br />I I <br />GFI @ 44" � I <br />A.F.F. I <br />I <br />GFI FOR I <br />GAR. D04 <br />GFI I <br />2 CAR GARAGE <br />I <br />I <br />I <br />I <br />I <br />0 I <br />V.H. VERIFY LOCATION j <br />ELECTRICAL PANEL IRRIGATION --- <br />`_1 p—F @ 4,P A.F.F. <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />Z <br />g <br />Z <br />Z <br />Q <br />a. <br />Z <br />4—J w <br />�o <br />0 LU <br />Ln ZD <br />ZD <br />LU <br />� N <br />- <br />Q� <br />B D. <br />• <br />N <br />N <br />Z Wz o z <br />j ty 1� � LPL <br />.W <br />W LL o, <br />¢ <br />12 <br />Z QMEMO °x <br />Z <br />ILL <br />W N<i <br />O V U O <br />WWW.FDSENG.COM <br />to <br />0 <br />N <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />o <br />w9 <br />za <br />f <br />Qz <br />OV U <br />�1Z <br />Q� <br />A <br />dJ <br />CL <br />H <br />Z® <br />iZ <br />Z <br />'a <br />,/ <br />� <br />Uj <br />wQ <br />V <br />= <br />O <br />o� <br />'—' <br />ILL <br />~ <br />J <br />Z <br />uo <br />k <br />CV <br />¢Lu <br /><ZUJ <br />Z <br />Z <br />JLur-I <br />(� <br />,..f <br />Q <br />aF- <br />IM <br />%1 <br />ob <br />Zr <br />7` <br />g <br />= <br />0 <br />aZ <br />rn O <br />,-+ <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: M]AMES <br />VERSION N0. 4mO <br />SHEET NO. <br />4.0 <br />