My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2996 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2996 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:28:33 AM
Creation date
2/19/2025 10:30:14 AM
Metadata
Fields
Template:
Building Plans
Street #
2996
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20748
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ao <br />N <br />i9 <br />�v <br />`ems <br />cno <br />ao <br />N <br />0 <br />TYP @ <br />CORNERS <br />U.N.O. <br />R&S <br />EGRESS <br />j---'-- <br />CC,0., <br />FIBERGLASa <br />SURROUN <br />j <br />TYP @ 2 STORY <br />p, <br />W.I.C. <br />I C <br />BEDROOM <br />4 <br />P <br />EO <br />_ <br />j ,-V v . . = <br />0 FLAT CLG. <br />I <br />8 -0 FLAT CLG. <br />' " <br />BEDROOM 3 <br />18 <br />oaI <br />I oa <br />b <br />CARPET <br />T - <br />°Q <br />8'-0" FLAT CLG. <br />w <br />CARPET OCC <br />= <br />rn <br />H2 D2 <br />ROOF G.T. <br />TIL <br />0 <br />- - <br />- <br />- <br />13'-0"- - <br />I <br />T <br />N <br />6'-5j" <br />2'.4" 4'_2�' <br />_ <br />- <br />G <br />ao <br />_ <br />I <br />TYP @ 2 STORY <br />� <br />J <br />4068 B.F. <br />� <br />_ <br />4 <br />S6 <br />j :7- <br />4 <br />_ <br />Y <br />=w w li <br />cnp z m <br />2'-3"�'� <br />4068 B.F. <br />•- <br />'- <br />N <br />60"X36" <br />SHOWER <br />FIBERGLA! <br />-------- <br />- R&S <br />00 <br />-�� J N <br />2668 <br />N <br />------------- <br />SURF OUN <br />4'-0" <br />I <br />6 10" <br />6'-1 5'4" 2 <br />41 2668 <br />13' <br />- <br />o <br />Q �Q <br />� <br />H 1 4 <br />M <br />I <br />" <br />BEDROOM 2 00 <br />' <br />24 8 <br />8'-0" FLAT CLG. <br />I <br />8' 0 <br />LA <br />CL o <br />- - I <br />I ATTIC <br />I <br />CARPET <br />o <br />- -- � - - --- - <br />T,P <br />_ <br />I� <br />� � <br />o I <br />- - 25S <br />La �= J oal CD <br />f <br />- <br />------� <br />00 <br />o <br />- <br />- m <br />13 <br />-..'.. <br />I <br />I o0 <br />W <br />I <br />j <br />1_ - <br />- ._o <br />-- - <br />D2Cn <br />SIM. <br />1- <br />- <br />"t <br />w/ (5) STUDS <br />S-8j" <br />'-9? 74" <br />6'-10, <br />5'.4" 2'-6" <br />I <br />I <br />Q, <br />16'-8" iO <br />T_7? v <br />14'-8" <br />OWNER'S <br />AR <br />SUITE <br />.A.G. <br />__ <br />15 <br />I <br />� <br />- <br />LOFT <br />14 <br />1 <br />fn <br />w <br />O <br />8'-0" FLAT CLG. <br />CARPET <br />I <br />I <br />8'-0" FLAT CLG. <br />4 <br />H2 D2 <br />13 <br />� <br />-. <br />ROOF G.T. <br />_ I <br />I <br />- <br />CARPET <br />- <br />- - <br />Or_ <br />- <br />04 <br />IQ <br />"' <br />11 z <br />H <br />_ <br />I o> <br />IOi <br />81 <br />9 <br />TYP @ 2 STORY <br />I=_j <br />I¢ <br />C <br />TYP @ 2 STORY <br />M <br />1 2 <br />I I <br />7 <br />I I I I <br />8 I <br />I I <br />S6 ` <br />I 1 <br />IIN`i <br />J <br />� <br />I I <br />I I <br />I I <br />I I I <br />I I <br />I <br />I�� <br />S6 <br />J_ <br />I <br />I <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />' VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />140C <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />>9'-0" <br />2x6 <br />SYP #2 <br />16" O.C. <br />" IF WITHIN 4FT OF END ZONE, USE DOUBLE STUDS AT <br />CORNERS <br />"" WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT <br />SEE C/S6 WALL SCHEDULE <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 j <br />S.H. <br />13 <br />20X38J <br />18JX371 <br />S.H. <br />14 <br />20 X 50 j <br />18 X 50 <br />S. H. <br />15 <br />20 X 63 <br />18 j X 62 j <br />S.H. <br />16 <br />20X72 <br />18JX714 <br />S.H. <br />1H2 <br />271/4X26 <br />26X254 <br />S.H. <br />1H3 <br />271/4X38j <br />26x371 <br />S.H. <br />1 H4 <br />27 j X 501 <br />26 x 50 <br />S.H. <br />1H5 <br />27jX63 <br />26X621/2 <br />S.H. <br />1H6 <br />27jX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 j X 251 /2 <br />S.H. <br />23 <br />37 j X 381j <br />36 j X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 j <br />36 } X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 j X 62 1/2 <br />S.H. <br />26 <br />37 } X 72 <br />36 j X 71 1/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73'} WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 � X 25 j <br />S.H. <br />33 <br />54 X 381j <br />52 } X 37 j <br />S.H. <br />34 <br />54 X 501 <br />52 } X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 j X 62 } <br />S.H. <br />36 <br />54 X 72 <br />52 j X 71 j <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />FIRST FLOOR PLAN -Al <br />SCALE: Y4'=V-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />With solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M 1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are Installed. Water heaters shall be <br />installed a min. of 18" above flr, per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />A+29.7 <br />/ -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />O <br />+28.3 / -36.4 <br />�E <br />+26.6 / -28.0 <br />�F <br />+26.6 / -32.2 <br />GG <br />SEE SN SHEET �H SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A1" <br />1ST FLOOR LIVING AREA <br />1093 <br />2ND FLOOR LIVING AREA <br />1491 <br />LIVING TOTAL <br />2584 <br />GARAGE <br />427 <br />FRONT ENTRY <br />35 <br />TOTAL AREA <br />3046 <br />0 <br />INSULATION REQ. <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />�R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />U r <br />Z <br />Na <br />CC <br />I Uf <br />Cct/ <br />4--+ w <br />Q <br />.0 <br />c <br />�N <br />`v v <br />m N <br />W <br />~ <br />N Cl) <br />cli <br />C) <br />Q� <br />�u.$ <br />� d <br />BIDCA <br />N b <br />� N <br />F" I��. <br />LW <br />Z <br />z O a <br />LLM <br />0 S <br />To the best of Ore Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Resldential Sth Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />�i <br />CbC ao: <br />201g0g <br />Z` <br />Z <br />LL <br />V <br />W <br />a <br />0 <br />L_ <br />Q <br />W <br />0 <br />* <br />N <br />Z <br />J <br />Ln <br />Q <br />z <br />$ � <br />00 <br />*k <br />co <br />0 <br />� <br />^Z <br />06 <br />Z <br />_5 <br />tj <br />8 <br />SCALE : AS NOTED <br />DATE : 10/29/2018 <br />TECH: KFRAZER <br />VERSION N0. 5ol <br />SHEET NO. <br />1.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.