Laserfiche WebLink
v <br />S <br />C) <br />0 <br />CN <br />s <br />10 -0 <br />I I TANK -LESS W/H <br />LO <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 00 O <br />it <br />C 51-011 ¢ - <br />STUB -OUT FOR 11 1'-O" C:)0 C:)�t GAS METER O o � <br />LO <br />c:fo O <br />J N x <br />°° I • MEASUREMENTS ARE FROM FINISHED FLOOR <br />>� • ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />o I "ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />E <br />E <br />0 <br />x <br />2 <br />N <br />r` <br />w <br />M <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19-4- <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />ill -0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />C3' <br />w <br />i <br />m <br />0 <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + o <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + +� <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ '-0" (TYP.) <br />6'-0" <br />+ <br />6'-0" <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ + <br />+ <br />+ + 7' <br />+++ <br />+ <br />+ <br />++ <br />+ + <br />+ + <br />+++ <br />+++ <br />+ <br />+ + <br />++++/++ <br />+ <br />+ + + + + + + + + + <br />+ <br />++ <br />+ + <br />+ + + + + <br />+ + <br />+ + + + + + + + + + <br />++ <br />+ <br />+ <br />+ + + + + + <br />+ <br />+ + + + + + + + + <br />+ + <br />+++ <br />+++++++ <br />+ <br />Ciu <br />— 15132" CDX <br />PLYWOOD OR 1 <br />7/16" OSB <br />BRIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3!4" wood panels or 2 x <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />1/8" gap i - <br />k <br />i <br />FILL CELLS STD. 90° HOOK ,— BOND BEAM <br />w <br />CC <br />STD. 90° <br />CONT. #5 <br />CONT. #5 > HOOK <br />BAR <br />BAR <br />OOC <br />#5 CONT. <br />FROM <br />❑�� <br />FOUNDATION <br />BOND BEAM <br />/) [_� — <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from <br /># OF 2nd FLOOR <br />above to bearing below. <br />STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. 2" min. <br />2" max )Small gap <br />• � 4 max. <br />a <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4 Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" 7min. <br />9 4" <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series Depth End Intermediate <br />BCI5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2 8d <br />3-8d <br />14' <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60sP <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT <br />at 12" o.c., clinched when possible. Stagger rows from opposite <br />required when Indicated or <br />-Hangers with side nailing. <br />max. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP <br />sides by 6". <br />- Hangers with sides not containing <br />WEB STIFFENER <br />t. <br />top flangeuthcuis. <br />DOUBLE JOIST CONNECTION <br />- Birdsmouth cuts. <br />N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />SQUASH BLOCKS AT INTERIOR <br />Boise Joist Blocking <br />Vertical load transfer =1900 plf max. along bearing wall <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or_tz <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />5/8" D <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />* over squash=20 blocks and beam below Load bearing wall must stack over <br />Non -stacking walls wall or beam below.* blocking and wall or beam below.* <br />require additional <br />consideration. Check Joist <br />local building When joists meet over wall, provide <br />code for appropriate I Joist can be offset <br />1/16" 1 3/4' minimum bearing for each. <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />lateral load. nail each side <br />1 at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or / <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />QY/ Provide adequate bearing <br />for each lapped joist. Use 10dx3" nails at Vo.c, for all joist <br />blocking panel *Non -stacking walls <br />10d nails require additional consideration. <br />SECTION �U INT. BRIG. WALL — <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />EEI <br />6A %" ROUND HOLE MAY if <br />6"6 DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1%" <br />8 <br />V-0" <br />1'-1" <br />V-2" <br />V-2" <br />V-3" <br />1'-3" <br />V-7" <br />V-11" <br />2,4" <br />2'-9" <br />3'-2" <br />3'-7" <br />___�__ �_�__ <br />Any 16" joist <br />12 <br />1'-0" <br />1'-1" <br />V-2" <br />V-2" <br />1'-3" <br />1'-9" <br />2'-4" <br />2'-11" <br />3--7" <br />4'-2" <br />4'-9" <br />5'-4" <br />Span (ft) <br />16 <br />V-0" <br />V-1" <br />l'-2" <br />V-2" <br />V-7" <br />2'-5" <br />3'-2" <br />3'-10" <br />4'-9" <br />5'-7" <br />6'-4" <br />7'-2" <br />20 <br />V-0" <br />V-1" <br />V-2" <br />1'-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11" <br />6'-11" <br />7'-11" <br />8'-11" <br />24 <br />V-0" <br />V-1" <br />l'-2" <br />V-3" <br />2'-5" <br />3'-7" <br />4'-9" <br />T-10" <br />7'-2" <br />8-4" <br />9'-6" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE, <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Joist hanger <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.)Nail with with 10-1 Old nails. <br />Install tight to top flange. SLEEVE THRU STEM ° <br />�. :•°. <br />SEE PLAN FOR °• . • 4 . <br />FOUNDATION INFO .14°' ° <br />STEM FOUNDATION <br />r GRADE _ncrr.rr OCE7 rn nr.r <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />:A <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />n depth <br />i <br />I -JOISTS BUCKETS <br />N.T.S. <br />rvU tlnmo1z 4 rvk, <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION " MID SPAN a <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />.�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18) 10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />_Z <br />PVC OR SCH40 SLEEVE <br />PI I IMRINr, I INF <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATIONFF PLUMBING LINE <br />a, A <br />d <br />111=11 �l I Q 1=1 I I ll; <br />�'' Il l l� °.All <br />SEE FND. PLN. <br />SIZE & REINF. <br />CD V <br />z o <br />z� <br />0 <br />Z <br />Q <br />U) Z <br />CD <br />(Z <br />• O U-i <br />Of <br />V) ZD <br />E <br />f— <br />U <br />or- <br />m <br />W <br />~ <br />N M <br />m M M <br />^ U <br />_E so <br />0 N <br />O o0 <br />U 4) <br />5 " aom <br />01-1 Y <br />Q rn <br />ca <br />0 ,� <br />av <br />rn Q o <br />� � <br />fA g cN o <br />� W �I c z <br />Z°,McN <br />52 <br />il•� (n LL O W <br />LU `nU v .N p" W <br />� LU <br />ane <br />0 <br />Z c <br />�� o <br />a <br />� z of <br />LUa "r A <br />f1,,/4,,�a., <br />�% 1 1""ii�A/& <br />x' e' l) P4 "pf <br />L <br />�{F "FDS (JM <br />4 •p <br />, <br />\ r <br />m U 0' 0 <br />!A L, O ` <br />ROF <br />„^ESSIO <br />r <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />AM 11FN% <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />oz <br />0 <br />zo <br />w <br />fF <br />u,a°da: <br />ooU0 <br />rr <br />zuz< <br />Q w Z <br />Lu <br />a co <br />co <br />v J <br />L <br />LU <br />zz <br />> <br />O <br />�z <br />5 <br />2: <br />a) <br />_0 <br />z <br />L <br />1 <br />�W <br />U <br />= <br />�J <br />0 <br />000 <br />81 <br />J <br />An <br />„ <br />6 <br />m d <br />L <br />g d - � <br />* <br />h <br />N <br />z`z� <br />Q 4wq <br />Z <br />^ <br />o <br />° fc <br />it <br />W <br />Lf) <br />w <br />=<,�Z <br />z 8 <br />J <br />,T--I <br />W <br />� <br />Ya <br />gF� <br />(v) <br />Q <br />Z <br />z <br />z <br />CY <br />az <br />co <br />O <br />0 <br />Z <br />LU <br />2 <br />w <br />rn <br />� <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAM ES <br />VERSION NO. 5ol <br />SHEET NO. <br />SIN 1 <br />li _TE7 i , -� -- r - 1 I .. r �i.�r'RI a i Ili, I,.i f,.ln it I <br />