<br />Re: Wood Construction Connector Compliance for 20151nternational Codes & 2017 Florida Codes -� CIO O 0
<br />To Whom It May Concern: � Q.
<br />(U �/�/�� Q.
<br />Section 2303.5 of the 2015 International Building Code (IBC) and 2017 Florida Building Code (FBC) specifies that
<br />.� VJ Q
<br />joist hangers shall be tested per ASTM D7147 Testing and Establishing Loads of Joist Hangers. Previous versions of
<br />the IBC and FBC required testing to comply with ASTM D1761 Test Method for Mechanical Fasteners in Wood. Both
<br />methods determine a connector's allowable load as the lowest of the following'
<br />1. Lowest ultimate of three tests (or average of 6) with a. safety factor of 3
<br />2. Average load at 1/8-inch deflection
<br />3. Calculations per American Wood Council National Design Specification for Wood Construction (NDS)
<br />The primary changes in ASTM D7147 are requirements to measure properties of the tested materials, such as steel
<br />strength, fastener strength, and wood specific gravity. The tested ultimate loads must be adjusted when tested
<br />material properties exceed the specified properties.
<br />ICC Evaluation Services (ICC-ES) revised AC13 Acceptance Criteria for Joist Hangers and Similar Devices in
<br />October 2016 to incorporate a methodology to evaluate products to the 20151-Codes. Simpson Strong -Tie is working
<br />on re-evaluating wood construction connector loads to the new standard to update our product evaluation reports to
<br />the 2015 [-Codes. As soon as the updated evaluation reports are completed, we will apply for Florida Product
<br />Approvals.
<br />However; reevaluating a large number of products will take time. While manufacturers work with product certification
<br />agencies to update their wood connector evaluation reports; we recommend that building departments under the
<br />2015 I -Codes and 2017 Florida Codes continue to accept code reports showing compliance to the 2012 and 2014
<br />editions, respectively, until July 2018.
<br />The information in this letter is valid until 6/30/2018 when it will be re-evaluated by Simpson Strong -Tie, Please visit
<br />www.strongfie.com for additional pertinent information. If you have questions or need further assistance regarding
<br />this matter, please contact the Simpson Strong -Tie Engineering Department at 800.999,5099.
<br />Sincerely,
<br />SIMPSON STRONG -TIE COMPANY INC.
<br />Keith Cullum, P.E., LEED AP dwfBDW
<br />Engineer, Southeast U.S. Branch
<br />Pagel of 1
<br />Simpson Strong -Tie Company Inc. 2221 Country Lane McKinney, TX 75069 Phone: 972.542.0326 Fax 972.542.4139 www.stronatiawm
<br />�e
<br />Z V
<br />0
<br />O
<br />L U
<br />O
<br />L�
<br />V �
<br />cz
<br />V o0
<br />O L
<br />W�
<br />Z�
<br />Z
<br />a
<br />a
<br />SHEET N0.
<br />PA 1.0
<br />rAP4 t
<br />rCIO >
<br />t H1 FL1
<br />`+*
<br />�*�: _
<br />Q .. � - F
<br />a � � �..- ...,.�^�<.'�.
<br />' 'fill
<br />3?/,* .'?'n,";� �� S'�.:
<br />`'•if ✓a
<br />� _-�
<br />� ,S 4�u
<br />pp++
<br />x.' '�,�, , d
<br />�J fl�y"y .��i'�+J`3'
<br />.�' ,�. ,fir �3 yx `•_
<br />A3
<br />FL17244.1
<br />ESR-3455
<br />A23
<br />FL10446.2
<br />ESR-26C6
<br />HD2142
<br />FL17232.3
<br />ESR-3445
<br />HU2142
<br />FL10856.4
<br />ESR-2549
<br />HD212-2
<br />FL17232.3
<br />ESR-3445
<br />HU212-2
<br />FL10858.4
<br />ESR-2549
<br />HD218
<br />FL17232.3
<br />ESR-3445
<br />HU218
<br />fL10856.5
<br />ESR-2549
<br />HD216-3
<br />FL17232:3
<br />ESR-3445
<br />HU216-3
<br />FL10858.1
<br />ESR-2549
<br />HD28
<br />FL17232.2
<br />ESR-3445
<br />HU26
<br />FL10858.3
<br />ESR-2549
<br />HD28-2
<br />FL17232.3
<br />ESR-3445
<br />HU28-2
<br />FL10856.4
<br />ESR-2549
<br />HD410
<br />FL17232.4
<br />ESR-3445
<br />HU410
<br />FL10856.9
<br />ESR-2549
<br />HD412
<br />FL17232,4
<br />ESR-3445
<br />HU412
<br />FL10856.9
<br />ESR-2549
<br />HD810
<br />FL17232.4
<br />ESR-3445
<br />HU810
<br />FL70856.10
<br />ESR-2549
<br />HD0410
<br />FL17241.7
<br />ESR-3444
<br />HUC0410
<br />FL11488.11
<br />SIM200804
<br />HGA10
<br />FL17699.1
<br />Evaluation Report
<br />HGAIOKT
<br />FL11470.4
<br />SIM200803
<br />HGAM10
<br />FL17689.1
<br />Evaluation Report
<br />HGAMIOKT
<br />FL11470.4
<br />SIM200803
<br />HHCP2
<br />FL17238.7
<br />ESR-3448
<br />HCP2
<br />FL10447.2
<br />ESR-2551
<br />HTA18
<br />FLt7680.4
<br />Evaluation Report
<br />HETA16
<br />FL11473.5
<br />SIM200802
<br />HTA20-18
<br />FL17880.4
<br />Evaluation Report
<br />HETA20
<br />FL11473.5
<br />SIM200802
<br />HTT16
<br />FL17324.2
<br />Evaluation Report
<br />HTT18
<br />FL11496.1
<br />ES-0130
<br />HTT45
<br />FL17324.2
<br />Evaluation Report
<br />HTT22
<br />FL11498.1
<br />ES-0130
<br />HTW18
<br />FL17244.8
<br />ESR-3455
<br />HTS16
<br />FL10456.22
<br />ESR-2813
<br />HTW20
<br />FL17244.8
<br />ESR-3455
<br />HTS20
<br />FL10456.23
<br />ESR-2613
<br />HTW24
<br />FL17244.8
<br />ESR-3455
<br />HTS24
<br />FL10458.24
<br />ESR-2613
<br />HTW30
<br />fL17244.8
<br />ESR-3455
<br />HTS30
<br />fL10458.28
<br />ESR-2613
<br />HTWM18
<br />FL6223.2
<br />Evaluation Report
<br />HTSM16
<br />FL11473.11
<br />SIM200802
<br />HTWM20
<br />FL6223.2
<br />Evaluation Report
<br />HTSM20
<br />FL11473.11
<br />SIM200802
<br />HUGT2
<br />FL6223.3
<br />Evaluation Report
<br />HGT2
<br />FL10458.18
<br />ESR-2613
<br />HUGT3
<br />FL6223.3
<br />Evaluation Repo
<br />D
<br />PRODUCT APPROVAL SPECIFICATION SHEET (2018) March 28, 2018
<br />As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the
<br />construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the product approval number for any of the applicable listed
<br />products.
<br />Category/Subcategory
<br />Manufacturer
<br />Product Description
<br />Approval Number(s)
<br />Test Pressures
<br />1. EXTERIOR DOORS
<br />A. SWINGING
<br />ThermaTru
<br />Firber-Classic and Smooth -Star (NON -IMPACT)
<br />FL20461.1
<br />+67.0/•87.0 psf
<br />ThermaTru
<br />Firber-Classic and Smooth -Star (NON -IMPACT)
<br />FL20461.8
<br />+67.0/-67.0 psf
<br />ThermaTru
<br />Firber-Classic and Smooth -Star (NON -IMPACT)
<br />F�046t,9
<br />+67.0/-67.0 psf
<br />ThermaTru
<br />FiPoer-Classic-Star(NON-IMPACT)
<br />FL20461.14
<br />+67.0/•67.Opsf
<br />ThermaTru
<br />Classic -Craft and Benchmark
<br />FLY5225.1
<br />+87.0/-87.0 psf
<br />ThermaTru
<br />Smooth -Star and Benchmark
<br />FL15225.5
<br />+87.0/-87.0 psf
<br />ThermaTru
<br />FiberClassic, Smoomstar, ClassicCraft, Rustic
<br />FL7840.1
<br />+87.0/-67.0 psf
<br />B. SLIDING
<br />MI Windows and Doors
<br />Series 420
<br />FL15332.1 - FL15332.5
<br />+40.0/-40.0 psf
<br />PGT
<br />Series 5570
<br />FL2S1.10
<br />C. SECTIONAL
<br />Clopay Building Products
<br />Residential VwndCode Doors W5 (8X7)
<br />FL15279.37
<br />+30.0/-32.0 psf
<br />Clopay Building Products
<br />Residential Vt4ndCode Doors W5 (16X7)
<br />FL15279.53
<br />+30.0/-30.0 psf
<br />Clopay Building Products
<br />Residential VwndCode Doors W6 (BX7)
<br />FL15279.85
<br />+38.0/-42.0 psf
<br />Clopay Building Products
<br />Residential VwndCode Doors W6 (16X7)
<br />FL15279.102
<br />+37.0/-41.0 psf
<br />D. METAL LOUVERED DRS
<br />Curries Division of AADG, Inc
<br />807,707,727,747,and 847 Single &Pairs of Doors
<br />FL11537.1
<br />NIA (see inst sht)
<br />2. WINDOWS
<br />A. SINGLE HUNG
<br />MI Windows and Doors
<br />Series 185
<br />FL17499.2
<br />+50.0%55.0 psf
<br />PGT
<br />Series 5500
<br />FL239.7
<br />B. HORIZONTAL SLIDER
<br />MI VJ�ndows and Doors
<br />Series 188
<br />FL15351.1
<br />+40.0/-50.0 psf
<br />C. FIXED
<br />MI Nhndows and Doors
<br />Series 185
<br />FL15349.1
<br />+40.0/-40.0 psf
<br />PGT
<br />Series 5520
<br />FL243.9
<br />D. MULLION
<br />MI Windows and Doors
<br />Series 5784
<br />FL15353.2
<br />N/A
<br />PGT
<br />Series 5500
<br />FL261.1
<br />N/A
<br />E. OTHER
<br />3. PANEL WALL
<br />A. SIDING
<br />James Hardie Building Prod.
<br />Cemplank Lap Siding and HardiePlank Lap Siding
<br />FL13192.1 - FL13192.2
<br />N/A
<br />B. SOFFITS
<br />Alside
<br />Solid and Vented Soffit
<br />FL15272.1 - FL15272.2
<br />+70.0/-70.0 psf
<br />C. OTHER
<br />4. ROOFING PRODUCTS
<br />A. ASPHALT SHINGLES
<br />GAF
<br />3 Tab, Dimensional
<br />FL10124.1
<br />N/A
<br />B. UNDERLAYMENTS
<br />Tamko
<br />151b Felt Underlayment
<br />FL12328.8
<br />N/A
<br />C. ROOFING FASTENERS
<br />NOT USED
<br />D. ROOF VENTILATORS
<br />Thompson Arch Metal Comp.
<br />Off Ridge Vents
<br />FL18918.1 - FL16918.4
<br />N/A
<br />Florida Metal Products, Inc
<br />Vent RV10
<br />FL21580.3
<br />N/A
<br />Lomanco, Inc
<br />DA•4 Exahust Vent
<br />FL17202.1
<br />N/A
<br />E. ROOFING TILES
<br />Boral Tile
<br />Villa 900
<br />FL7849.27 - FL7849.28
<br />N/A
<br />Borel Tile
<br />Saxony 900
<br />FL7849.18 - FL7649.20
<br />N/A
<br />F. METAL ROOF
<br />Gulf Coast Supply & Manufacturing, LLC
<br />0.032" Aluminum GulfLok 18" wide roof panel
<br />FL11651.2 R3
<br />N/A
<br />5. SHUTTERS
<br />A. STORM PANELS
<br />Global Protection Products
<br />Galvanized Steel Storm. Panels
<br />FL15076.1 - FL15076.2
<br />N/A
<br />All American Shutters &Glass
<br />Galvanized Steel Storm Panels
<br />FL17869.1
<br />N/A
<br />6. STRUCTURAL
<br />COMPONENTS
<br />A. WOOD CONNECTORS/
<br />USP Structural Conn.
<br />see chart
<br />ANCHORS
<br />Simpson Strong -Tie
<br />see chart
<br />S. TRUSS PLATES
<br />ITW Building Components
<br />Alpine Truss Plates
<br />FL1999.1 - FL1999.4
<br />N/A
<br />MiTek Industries, Inc.
<br />Truss Plates
<br />FL2197.1 - fL2197.5
<br />NIA
<br />C. ENGINEERED LUMBER.
<br />Weyerhaeuser
<br />Rim Board, LVL, PSL, tSL
<br />FL6527.1 - FL6527.5
<br />N/A
<br />D. MATERIAL
<br />Cast -Crete Corp.
<br />High Strength Concrete Lintels
<br />FL158.1
<br />N/A
<br />Commercial Concrete Products, Inc.
<br />High Strength Concrete Lintels
<br />FL1774
<br />NIA
<br />The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the
<br />jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I
<br />understand these products may have to be removed if approval cannot be demonstrated during inspection.
<br />APPLICANT SIGNATURE
<br />DATE
<br />
|