My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3052 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3052 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:10:02 AM
Creation date
2/19/2025 10:31:11 AM
Metadata
Fields
Template:
Building Plans
Street #
3052
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20407
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br />2_6 O <br />CU 'T3 <br />.� V 4- � <br />C�j <br />^^`` <br />O O W <br />March 20, 2018 O � � O <br />O LL <br />0 CZ 0 > <br />Re: Wood Construction Connector Compliance for 2016 International Codes & 2017 Florida Codes . � <br />E <br />III. - <br />To }a Q <br />Whom It May Concern: <br />CZ <br />Section 2303 5 of the 2015 International Building Code (IBC) and 2017 Florida Building Code (FBC) specifies that � .� V) Q <br />joist hangers shall be tested per ASTM D7147 Testing and Establishing Loads of Joist Hangers. Previous versions of <br />the IBC and FBG required testing to comply with ASTM 01781 Test Method for Mechanical Fasteners in Wood. Both <br />methods determine a connector's allowable load as the lowest of the following: <br />1. Lowest ultimate of three tests (or average of 6) with a safety factor of 3 <br />2. Average load at 1/8-inch deflection <br />3. Calculations per American Wood Council National Design Specification for Wood Construction (NDSj <br />The primary changes in ASTM D7147 are requirements to measure properties of the bested materials, such as steel <br />strength, fastener strength, and wood speck gravity. The tested ultimate loads must be adjusted when tested <br />material properties exceed the specified properties. <br />ICC Evaluation Services (ICC-ES) revised AC13 Acceptance Criteria for Joist Hangers and Sirralar Devices in <br />October 2016 to incorporate a methodology to evaluate products to the 20151-Codes. Simpson Strong -Tie is working <br />on re-evaluating wood construction connector loads to the new standard to update our product evaluation reports to <br />the 2015 I -Codes: As soon as the updated evaluation reports are completed, we will apply for Florida Product <br />Approvals. <br />However, reevaluating a large number of products wilt take time. While manufacturers work with product certification <br />agencies to update their wood connector evaluation reports we recommend that building departments under the <br />2015 I -Codes and 2017 Florida Codes continue to accept code reports showing compliance to the 2012 and 2014 <br />editions; respectively, until July 2018. <br />The information in this letter is valid until 6/30/2018 when d wilt be re-evaluated by Simpson Strong -Tie. Please visit <br />www.stroncitie.com for additional pertinent information. If you have questions or need further assistance regarding <br />this matter, please contact the Simpson Strong -Tie Engineering Department at 800,999.5099. <br />Sincerely, <br />SIMPSON STRONG -TIE COMPANY INC. <br />Keith Cullum, R.E., LEER AP dWBDW <br />Engineer, Southeast U.S. Branch <br />Page I of 1 <br />Simpson Strong -Tie Company Inc. 2221 CountryLane. McKinney,: TX75069 Phone: 972,542.0326 Fez 972.542.4139 wwa.slandtie.com <br />W <br />- + <br />CZ <br />O <br />0- <br />o <br />U <br />O <br />L� <br />V! <br />M� <br />W <br />o �- <br />W <br />Z� <br />Z <br />a <br />SHEET N0. <br />PA 1.0 <br />A3 <br />FL17244.1 <br />ESR-3455 <br />A23 <br />FL10448.2 <br />ESR-2806 <br />HD210-2 <br />FL17232.3 <br />ESR-3445 <br />HU210-2 <br />FL10856.4 <br />ESR-2549 <br />HD212-2 <br />FL17232.3 <br />ESR-3445 <br />HU212-2 <br />FL10856.4 <br />ESR-2549 <br />HD216 <br />FL17232.3 <br />ESR-3445 <br />HU216 <br />FL10856.5 <br />ESR-2549 <br />HD218.3 <br />FL17232.3 <br />ESR-3445 <br />HU218-3 <br />FL10858.1 <br />ESR-2549 <br />H 28 <br />D <br />FL17232.2 <br />ESR-3445 <br />H U26 <br />1 8 3 <br />FL 0 56. <br />ESR-2549 <br />HD28-2 <br />FL17232.3 <br />ESR-3445 - <br />HU28-2 <br />FL10856.4 <br />ESR-2549 <br />HD410 <br />FL17232.4 <br />ESR-3445 <br />HU410 <br />FL10856.9 <br />E5R-2549 <br />HD412 <br />FL17232.4 <br />ESR-3445 <br />HU412 <br />FL10858.9 <br />ESR-2549 <br />HD610 <br />FL17232.4 <br />ESR-3445 <br />HU610 <br />FL10858.10 <br />ESR-2549 <br />HD0410 <br />FL17241.7 <br />ESR-3444 <br />HUC4410 <br />FL11468.11 <br />SIM200804 <br />HGA10 <br />FL17699.1 <br />Evaluation Report <br />HGA101CT <br />FL11470.4 <br />SIM200803 <br />HGAM10 <br />FL17899.1 <br />Evaluation Report <br />HGAM10KT <br />FL11470.4 <br />SIM200803 <br />HHCPZ <br />FL17238.7 <br />ESR-3448 <br />HCP2 <br />FL10447.2 <br />ESR-2551 <br />HTA18 <br />FL17880.4 <br />Evaluation Report <br />HETA16 <br />FL11473.5 <br />SIM200802 <br />HTA20-18 <br />FL17880.4 <br />Evaluation Report <br />HETA20 <br />FL11473.5 <br />SIM200802 <br />HTT18 <br />FL17324.2 <br />Evaluation Report <br />HTT16 <br />FL11498.1 <br />ES-0130 <br />HTT45 <br />FL17324.2 <br />Evaluation Report <br />HTT22 <br />FL11498.1 <br />ES-0130 <br />HTW18 <br />FL17244.8 <br />ESR-3455 <br />HTS16 <br />F(_10458.22 <br />ESR•2613 <br />HTW20 <br />FL17244.6 <br />ESR-3455 <br />HTS20 <br />FL10456.23 <br />ESR-2813 <br />HTW24 <br />FL17244.8 <br />ESR-3455 <br />HTS24 <br />FL10458.24 <br />E5R-2813 <br />HTW30 <br />FL17244.8 <br />ESR-3455 <br />HTS30 <br />FL10458.26 <br />ESR-2613 <br />HTWM18 <br />FL8223.2 <br />Evaluation Repo <br />PRODUCT APPROVAL SPECIFICATION SHEET (2018) March 28, 2018 <br />As required b Florida and Florida Administrative 9 7 lease provide the information and approval building components on e y Statute 553,842 Code B- 2, p pr a numbers on the listed below if they will be utilized th <br />construction project for which you are applying for a building permit. We recommend you confect your local product supplier should you not know the product approval number for any of the applicable listed <br />products. <br />Category/Subcategory <br />Manufacturer <br />Product Description <br />Approval Number(s) <br />Test Pressures <br />1. EXTERIOR DOORS <br />A. SWINGING <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20481.1 <br />+67.0/-67.0 psf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461.6 <br />+87.0/-87.0 psf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL2pggl,g <br />+87.0/-67.0 psf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461.14 <br />+67.0/-67.0 psf <br />ThermaTru <br />Classic -Craft and Benchmark <br />FL15225.i <br />+67.0%87.0 psf <br />ThermaTru <br />Smooth -Star and Benchmark <br />FL15225.5 <br />+67.0/-67.0 psf <br />ThermaTru <br />FibarClassic, Smoothstar, ClassicCraft, Rustic <br />FL7640.1 <br />+67.0/-87.0 psf <br />B. SLIDING <br />MI Windows and Doors <br />Series 420 <br />FL15332.1 - FL15332.5 <br />+40.0/-40.0 psf <br />PGT <br />Series 5570 <br />FL251.10 <br />C, SECTIONAL <br />Clopay Building Products <br />Residential WindCode Doors W5 (8X7) <br />FL15279.37 <br />+30.0/-32.0 psf <br />Clopay Building Products <br />Residential WindCode Doors W5 (16X7) <br />FL15279.53 <br />+30.0/-30.0 psf <br />Clopay Building Products <br />Residential WindCode Doors W6 (8X7) <br />FL15278.85 <br />+38.0/-42.0 psf <br />Clopay Building Products <br />Residential WindCode Doors W8 (16X7) <br />FL15279.102 <br />+37.0/-41.0 psf <br />D. METAL LOUVERED DRS <br />Curries Division of AADG, Inc <br />607,707,727,747,and 847 Single &Pairs of Doors <br />FL11537.1 <br />N/A (see inst sht) <br />2. VNND0INS <br />A. SINGLE HUNG <br />MI Windows and Doors <br />Series 165 <br />FL17499.2 <br />+50.0/-55.0 psf <br />PGT <br />Series 5500 <br />FL239.7 <br />B. HORIZONTAL SLIDER <br />MI Windows and Doors <br />Series 188 <br />FL15351.1 <br />+40.0/-50.0 psf <br />C. FIXED <br />MI Windows and Doors <br />Series 185 <br />FL15349.1 <br />+40.0/-40.0 psP <br />PGT <br />Series 5520 <br />FL243.9 <br />D. MULLION <br />MI Windows and Doors <br />Series 5784 <br />FL15353.2 <br />N/A <br />PGT <br />Series 5500 <br />FL261.1 <br />N/A <br />E. OTHER <br />3. PANEL WALL <br />A. SIDING <br />James Hardie Building Prod. <br />Cemplank Lap Siding and HardiePlank Lap Siding <br />FL13192.1 - FL13192.2 <br />N/A <br />B. SOFFITS <br />Alside <br />Solid and Vented Soffit <br />FL15272.1 - FL15272.2 <br />+70.0/-70.0 psf <br />C. OTHER <br />4. ROOFING PRODUCTS <br />A. ASPHALT SHINGLES <br />GAF <br />3 Tab, Dimensional <br />FL10124.1 <br />N/A <br />B. UNDERLAYMENTS <br />Tamko <br />151b Felt Underlayment <br />FL12328.6 <br />N/A <br />C. ROOFING FASTENERS <br />NOT USED <br />D. ROOF VENTILATORS <br />Thompson Arch Metal Comp. <br />Off Ridge Vents <br />FL16918.1 - FL16918.4 <br />N/A <br />Florida Metal Products, Inc <br />Vent RV10 <br />FL21580.3 <br />NIA <br />Lomanco, Inc <br />DA-4 Exahust Vent <br />FL17202.1 <br />NIA <br />E ROOFING TILES <br />Boral Tile <br />Villa 900 <br />FL7649.27 - FL7849.28 <br />N/A <br />Boral Tile <br />Saxony900 <br />FL7849.18-FL7849.20 <br />N/A <br />F. METAL ROOF <br />Gulf Coast Supply &Manufacturing, LLC <br />0,032"Aluminum Gulfl,ok 16" vrida roof panel <br />FL11651.2 R3 <br />N/A <br />5. SHUTTERS <br />A. STORM PANELS <br />Global Protection Products <br />Galvanized Steel Storm Panels <br />FL15076.1 - FL15076.2 <br />N/A <br />All American Shutters $Glass <br />Galvanized Steel Storm Panels <br />FL17869.1 <br />N/A <br />S. STRUCTURAL <br />COMPONENTS <br />A. WOOD CONNECTORS/ <br />USP Structural Conn. <br />see chart <br />ANCHORS <br />Simpson Strong -Tie <br />see chart <br />B. TRUSS PLATES <br />ITW Building Components <br />Alpine Truss Plates <br />FL1999.1 - FL1999.4 <br />NIA <br />MITek Industries, Inc. <br />Truss Plates <br />FL2197.1 - FL2197.5 <br />NIA <br />C. ENGINEERED LUMBER <br />Weyerhaeuser <br />Rim Boats, LVL, PSL, LSL <br />FL6527.1 - FL6527.5 <br />N/A <br />D. MATERIAL <br />Cast -Crete Corp. <br />High Strength Concrete Lintels <br />FL158.1 <br />N/A <br />Commercial Concrete Products, Inc. <br />High Strength Concrete Lintels <br />FL1774 <br />N/A <br />The products listed below did not demonstrate product approval at plan review. 1 understand that at the time of inspection of these products, the following information must be available to the inspector on the <br />jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I <br />understand these products may have to be removed if approval cannot be demonstrated during inspection. <br />APPLICANT SIGNATURE <br />DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.