My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3052 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3052 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:10:02 AM
Creation date
2/19/2025 10:31:11 AM
Metadata
Fields
Template:
Building Plans
Street #
3052
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20407
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m <br />rn <br />Q <br />Co <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />t <br />20000 AMP #12 copper to 20 amp ckts <br />A <br />#10-2 copperto WH <br />#10-3 copperto dryer <br />MAIN <br />0 <br />2J0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />� <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and. <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEPF- <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />FG.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIGACCESS <br />TRACK LIGHT <br />-�— — <br />FLUORESCENT LIGHT FIXTURE <br />© <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />I-D <br />PUSH BUTTON SWITCH (OPTIONAL) <br />1-0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />I� <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />WP DISC. <br />GFI H.I <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />L 1^ ^1 nr-n [+ncno <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VCI-UrT IVICIMM <br />LOCATION WITH <br />BUILDER <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Y <br />rt ; <br />a <br />i "r ei t i r " <br />a .:_..� <br />M <br />0 <br />— o <br />N <br />Z <br />Q <br />d. <br />13 <br />V/�)' <br />'W U_j <br />.V <br />O W <br />\�Lh <br />L <br />0 <br />H— <br />�L C) <br />CD <br />o 0 <br />m <br />r <br />Wto <br />N <br />CT co <br />co <br />— 8 <br />l <br />N-0 <br />O o 0 <br />oai p <br />U ca <br />C LA_0D <br />< <br /><Co a' <br />Q-o <br />8-v <br />'Zr <br />o' Q d <br />N C LLB D C <br />N �O <br />a <br />O M 2 W <br />W <br />Z �M�Z �' z <br />!� <br />w� F. _ <br />Y. <br />2NJ N <br />WOa <br />o4�' <br />♦♦—,� �L <br />iWcc <br />in <br />Z 0 <br />� <br />aWs <br />Z mooC <br />LL Q <br />W a N¢M A <br />a' <br />O Ly U O <br />WWW.FDSENG.COM <br />00 <br />cs <br />N <br />0 <br />0 <br />T <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering porlions of the drawing pages bearing <br />Engineer's signature and seal. <br />AM <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />oz <br />uua <br />z <br />Wain <br />J <br />ooa0 <br />�:Z�Z <br />0— <br />�o J`w <br />Ras' <br />Q <br />�� <br />S <br />n <br />tJ <br />W" <br />m o <br />n/L�_� <br />W <br />/Q <br />r 1 <br />Z Q <br />¢ <br />Z <br />Z <br />Z <br />a <br />LL <br />w <br />z <br />J <br />=� <br />N <br />W <br />O <br />�W <br />Q <br />I_ <br />o'0Z�z <br />Q U Q <br />O <br />-I <br />U <br />Pma <br />z <br />voo <br />Z <br />Z <br />-i <br />�o�o <br />Lu it tj <br />LU J <br />T-I <br />Z <br />on z o <br />� <br />V <br />z <br />CC W Z <br />Z <br />o <br />'tjiLrj <br />... <br />= <br />-� Z <br />a g <br />,--I <br />�1 <br />a <br />o <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAMES <br />VERSION N0. 4s0 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.