My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3210 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3210 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 2:45:07 PM
Creation date
2/19/2025 10:31:56 AM
Metadata
Fields
Template:
Building Plans
Street #
3210
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
9309
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />J <br />15/32" CDX <br />m¢ <br />PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH <br />(ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" <br />WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />8d RING SHANK NAILS @ 6" O.C. EDGES & <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH <br />2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND <br />OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING <br />CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ o <br />+ + <br />+ + <br />+ + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+.co <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ <br />+ + <br />+ <br />+ <br />'4' (TYP.) <br />6'-0" <br />+ + + <br />6'-0" <br />+ + <br />+ <br />+ + <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+++ <br />+++ <br />+ 4 <br />+ <br />+ <br />+ <br />+ <br />+++o <br />+ <br />+ + <br />+ + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ ++ <br />+ <br />+ <br />+ <br />+ <br />+ <br />++++++++++ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ o <br />+ <br />+ + <br />++ ++ <br />++++++ <br />++ <br />++ <br />+ <br />++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking / <br />1/8" gap —, <br />FILL CELL <br />U) <br />w <br />CONT. #5 > STD. 90' <br />BAR HOOK <br />STD. 900 HOOK <br />BOND BEAM <br />BOND BEAM STEP <br />US <br />MU <br />CONT. #5 <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. Small 2" min. <br />2" ) gap <br />max. � 4 max. <br />�d <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". - Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION top flangeuthcuts. <br />- Birdsmouth cuts. N.T.S. <br />Under 2nd floor cnlumn w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />over squash=20 blocks and <br />Non -stacking walls <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />lateral load. nail each side <br />10'-0" at bearing. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 00 O <br />5'-0"SD b <br />a _ <br />STUB -OUT FOR 1'-O" o <br />GAS METER O 0 <br />� U <br />O F <br />N Oz <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) USP HTW20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />higher than 15001b <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />BCI5000s <br />9-112" <br />2-8d 2-8d <br />11-7/8" <br />2-8d 3-8d <br />14" <br />2-8d 5-8d <br />BCI 6000s8 <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d 2-8d <br />2-8d 3-8d <br />14" <br />2-8d 5-8d <br />16" <br />2-8d 6-8d <br />BCI60s® <br />11-7/8" <br />2-8d 3-8d <br />14" <br />2-8d 5-8d <br />16" <br />2-8d 6-8d <br />BCI90s® <br />11-7/8" <br />3-16d 3-16d <br />14" <br />5-16d 5-16d <br />16" <br />6-16d 6-16d <br />Plumbing <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />�1 3/4" minimum bearing for each. I -Joist can be offset <br />Provide adequate bearing <br />for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />d nails SECTION @INT. BRIG. WALL require additional consideration. <br />SECTION <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />7791M <br />fic <br />6" A 1Yz" ROUND HOLE MAY 6" 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1%" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Yz" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />Joist hanger <br />5/81 <br />THRL <br />BOLT <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL HTA 20-18 / HTA 20 <br />INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) ;,I I II I II I II I �1TT� T�v TT1 <br />Nail with 10- 10d nails. — <br />Install tight to top flange. SLEEVE THRU STEM ° ' ' <br />.. <br />SEE PLAN FOR--'°• • . • <br />FOUNDATION INFO a' <br />STEM FOUNDATION <br />\ _ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />D depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE REINF. SEE PLAN <br />A <br />H_ <br />i (2) #5 REBAR <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF NOTE: <br />UPLIFT VALUE <br />SECOND RT16 IS BASED ON <br />S.P.F. <br />o USP RT16 USING <br />I® 16-8d x1 1/2" NAILS <br />7� UPLIFT = 1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />d- ° <br />d a <br />a <br />r�TTT <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />° <br />— SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />A a <br />a <br />PVC OR SCH40 SLEEVE <br />/ r PLUMBING LINE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />d a' a <br />• aO' a a° G <br />11-1 II a Q ° ` I �I I I II II <br />. � t4. <br />°. <br />I Jil- <br />r <br />SEE FND. PLN. <br />ol SIZE & REINF. <br />O!P <br />o <br />IDz M <br />❑ <br />_ <br />Z CO <br />z� <br />Q <br />❑J <br />z <br />W cn <br />a-1 w <br />0 <br />w <br />Lv <br />ZD <br />.12 <br />~ <br />o <br />o <br />F— <br />U <br />0 <br />m � <br />W E <br />t— <br />-8 <br />aw <br />(DM M <br />C M <br />N '2 M <br />Ooo <br />= ai <br />(D <br />U <br />-FL 00 <br />, m <br />C Y <br />Q 0) <br />Qro <br />LO O V <br />OL <br />� Q O <br />A I <br />B D. <br />NCBDC <br />070! <br />` 1'Siiil <br />CD <br />N <br />co <br />�j <br />co L�S� •• •...� <br />J <br />dib <br />>�ocl <br />�• <br />Z: <br />Aa�L <br />FLO <br />�q��� <br />ar7........ <br />Q" <br />To the best of the Engineer's kno etion, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />Z ON <br />n <br />0 <br />-N <br />M O <br />Q C!) U Ln <br />a (n •L <br />QI Ln <br />Q <br />I'_ M <br />cl� U Q 00 <br />Q � <br />� <br />z <br />WJ C) <br />oz <br />=o <br />o <br />za <br />w¢�� <br />Uz00 <br />Z�w� <br />z <br />U0z <br />Se2W <br />Ea2u <br />0'T LL o <br />U) <br />" L9 o <br />W <br />O. <br />}U <br />�z <br />Ln�3 <br />2: <br />Q <br />O <br />-0 <br />� <br />�z <br />U <br />= <br />N <br />U <br />L� <br />Lu <br />�0o <br />I- <br />U222 <br />a <br />zaoa <br />fV <br />A <br />1 ` <br />z � W <br />Q CZ,J <br />Z Q <br />cl� <br />OW <br />2E <br />z <br />z <br />2 <br />�aUP <br />W <br />LJ <br />J <br />� <br />T--I <br />W <br />cW <br />G <br />Q <br />?ado <br />Ln CH <br />U <br />8 <br />Ln <br />l0 <br />z <br />z <br />M <br />Ce CN <br />o <br />Lfi <br />g <br />= <br />z <br />¢z <br />g <br />r, <br />,--I <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 2x0 <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.