My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3221 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3221 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 2:56:58 PM
Creation date
2/19/2025 10:32:13 AM
Metadata
Fields
Template:
Building Plans
Street #
3221
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
19244
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A ti <br />�ni n i 1n WEATHER <br />/E BARRIER & <br />IARILY SECURE <br />WEATHER <br />`RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weat <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL ° ° O <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />\\� <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN -� <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI; <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />Eon <br />SELF -ADHERED FLASHING <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />- 3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-l" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />NAILING FLANGE 1 <br />DO NOT FLASH OVER 2 SEAL TOPS OF JOISTS <br />BOTTOM NAILING p UNDER DECKING <br />FLANGE O (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />E <br />AM <br />ruyarni�u r�hanuvEa <br />SELF-ADHEF <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />1�4 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />IN <br />0 <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground (�- <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING ■ • FOUNDATION WEEP SCREED <br />DECK JOIST ET ' OUTSIDE CORNER I • <br />WIRE LATH <br />Q <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No. 15 asphalt felt free from holes and breaks complying <br />with ASTM D 226 for Type l felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy, sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as #Oin each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />NOT USED HOW NOT USED NOT USED ' SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />U)� <br />z_zM o <br />O° <br />z� <br />d <br />O <br />Cl- <br />Z <br />c /) UI <br />4-1 <br />(10 0 <br />'U - <br />w <br />O <br />~ <br />0 <br />= <br />Cl) <br />l� <br />o <br />U <br />LU <br />a co co <br />C M co <br />H E <br />-8 <br />M00 <br />RI <br />EE2 <br />000 <br />_r <br />0 <br />rLL� <br />M <br />U <br />0 32 <br />(%% CL o <br />Lo 0v <br />Q 0M <br />rnQ o <br />A 1 <br />B D® <br />14 C <br />ti <br />N <br />N <br />0 CV <br />.4- <br />fn a o d rn <br />V o <br />cs oNoo <br />Z <br />ZmMrn O <br />� <br />J <br />lL Z <br />9 u <br />W a <br />tL <br />a LU <br />me <br />Q W U Q p rL <br />z <br />Dim= <br />H o <br />00 <br />fZ <br />m o^O <br />m ro <br />ZN�E�r <br />WLV <br />d� <br />W a NaM <br />O <br />O V <br />U O1-- <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />I <br />O <br />CD <br />Z N <br />O aD n <br />1-1 4-Jo <br />E/-E M O <br />M <br />U')a <br />Q to 170 <br />V) •L d- <br />Q <br />" LL <br />CL M <br />QC U 170 <br />Q <br />ZZ <br />a <br />E00 <br />3: ry <br />W <br />J <br />oz <br />;o <br />w0 <br />Za <br />Wa9� <br />�Zo0 <br />ZWLu <br />i_0�Z <br />O Lu <br />aaO,n <br />11 0 <br />---I <br />SF o <br />L <br />41. <br />o <br />z Z <br />Q� <br />M <br />� <br />¢ Ov <br />> <br />W <br />C1 <br />�W <br />g <br />M <br />U� <br />0 <br />z <br />2: <br />O <br />O <br />cc <br />Q <br />V <br />0- <br />LU <br />0- <br />W <br />w <br />o� <br />0 <br />0 <br />max; <br />f- <br />Xo8 <br />x P <br />¢ <br />w o <br />U 8- <br />r%J <br />a<o! <br />Q <br />d- <br />Z <br />Z <br />O LL O <br />wa <br />W <br />J <br />Lli <br />r-1 <br />413 <br />W <br />2: <br />�a�o <br />� o� z 8 <br />Pia <br />w~~ <br />M <br />10 <br />Z <br />Z <br />��Z <br />k <br />z <br />�j <br />z <br />0 <br />¢z <br />O <br />2 <br />rn <br />,-i <br />a <br />U) <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.