My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3221 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3221 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 2:56:58 PM
Creation date
2/19/2025 10:32:13 AM
Metadata
Fields
Template:
Building Plans
Street #
3221
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
19244
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VENTED SOF <br />46 SQ. FT. <br />\/CRIT17I71 Cr11=CIT r_-7 C!n CT <br />V L_ 1• 1 L_ L f W V 1 1 1 1 %.f W V vc • I I <br />ATTIC VENTILATION CALCULATIONS - Al <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />ventilation of vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be provided <br />. <br />SQIN. of <br />SQ. IN. of <br />Ventilators <br />(See Elev ) <br />required soffit <br />ventilation <br />soffit <br />by upper <br />Ventilation <br />Ventilation <br />needed <br />required <br />needed <br />ventilators <br />Main <br />29.00000 <br />1.000000 <br />Floor <br />2373 <br />2278 <br />325 <br />1139 <br />81 <br />570 <br />0 <br />573.0 <br />435.0 <br />138.0 <br />(Zone 1) <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 5th ED. RESIDENTIAL. <br />VENTED SOFFIT LEGEND <br />IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED <br />AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. <br />IF <br />LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. <br />VENTED SOFFIT <br />1'-0" <br />SOFFIT <br />ROOF PLAN <br />SCALE: %4'=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. <br />** (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SO. IN. OF NET FREE AREA / FT. <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed <br />(Dr <br />Zz <br />Lu0 <br />Z <br />Q <br />J <br />d <br />z <br />V) 0 <br />� cn <br />w <br />o <br />U — <br />Ow <br />0� <br />V) <br />~ <br />0 <br />to <br />o 0 <br />V <br />W <br />E <br />—8 <br />�M co <br />c w M <br />mach <br />Ooo <br />oin (D <br />L ll N <br />,I III Ly N <br />a p <br />`� n d <br />Qo rn <br />rnQo <br />A, <br />B <br />D® <br />N-C-B•D-C <br />E11 <br />ll <br />• C <br />i <br />z <br />(p N <br />co <br />W <br />S. <br />o <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />O () r-, <br />4-J o <br />r>+ M O <br />M <br />a 0 In <br />0 <br />Q U_ <br />QC U Q, <br />Q � <br />� <br />z�� <br />zz <br />LU C:) <br />J C:) <br />W <br />d' <br />J <br />0z <br />� p <br />z¢a <br /><¢ <br />F- <br />w¢etY <br />UZ80 <br />Z w w ix <br />�U 0 � Z <br />ay.'X� <br />> a2Lo <br />� u, <br />o04 <br />L <br />FFzO <br />w� <br />o� <br />zz <br />o <br />o^` <br />2:z <br />C1 <br />e <br />a <br />� <br />M <br />OU <br />•� <br />-0 <br />, <br />C: <br />Z <br />J <br />c <br />0 <br />a <br />= <br />(� <br />aILL <br />�LU <br />�U_ �o <br />F <br />0 <br />—t <br /><�P <br />x <br />_r-4 <br />ro-aoa <br />ZW J <br />z Q <br />Q <br />U, ¢ <br />oww <br />(j U X <br />Z <br />K <br />M <br />JT.� <br />W <br />W <br />=F¢-u- <br />W <br />Q <br />z <br />cizu <br />2 <br />~ <br />M <br />*k <br />in <br />z <br />z <br />a � Z <br />Z <br />J z <br />O <br />J <br />T <br />i <br />a z <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION N0. 10 <br />SHEET NO. <br />5.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.