ELECTRICAL DETAIL: <br />v <br />FIRST FLOOR ELECTRICAL PLAN <br />1 /411 = 1'-011 <br />A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />LINE OF ROOF <br />QCi nlAr <br />SECOND FLOOR ELECTRICAL PLAN <br />1 /4„ = 1'-0" <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR THE <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />2011 NFPA 70 NATIONAL FIRE ALARM CODE. <br />6, ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER 2011 NEC. <br />7. IN ALL AREA SPECIFIED IN NEC 2011 210.52, ALL 125 VOLT, 15 <br />AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT <br />RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACL ES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER N.E.C. <br />210.12 <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION <br />PURPOSES. <br />200A !NILDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />io <br />DOOR <br />SWITCH <br />7�__ <br />JAMB <br />0 <br />4 1/2" <br />DUPLEX _ <br />OUTLET io <br />TRIM <br />ih <br />BASE <br />° - <br />TRIM <br />q <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />ROUGH FRAMING <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />SW STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />— DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />}A CLG MNT LT FIXTURE <br />B CLG MNT PREWIRE - FIXTURE BY OWNER <br />-'1'- SURFACE MNT FIXTURE <br />-(Tr)- WALL MNT FIXTURE <br />NOTE: <br />�, 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />®l 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />RECESS CAN OR LED OWNER <br />k) 50W PAR20 NFL 4" MINI ROUND RECESS <br />@�` 50W FAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />-U-24- UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />24 `7 24" VANITY LIGHTING <br />36 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />® EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />CHIMES (DELETE W/ INTERCOM) <br />® MASTER STATION <br />® ELEC PANEL <br />P VACUM OUTLET AT 12" <br />ACEILING RETURN AIR (W/ SIZE) <br />® A/C REGISTER <br />TO THERMOSTAT <br />® SECURITY PAD <br />ETt ELEC METER <br />E <br />>bM <br />o <br />co <br />omm�-a <br />C: <br />W <br />e <br />O <br />O U- o <br />u o <br />R Q <br />VJ <br />�N <br />U p- <br />a � <br />u <br />LU Q� <br />N <br />H <br />3 <br />^, <br />� <br />70a <br />Ltl <br />0W (6 WQH <br />W�Q w2� wgyzw Z <br />W (D W <br />Q Q V <br />E02_jQO¢wQ�0O��O <br />��OJZLLLL•OZ��❑~¢Q <br />E— <br />C� 0 <br />0U)w 0ZOwoomzz�L) <br />_jo°a>zYQZz" 0Wa0 <br />z <br />Q�WO�I¢—� �w`320 < <br />OLL Q 0 O 0 wLL <br />N <br />O <br />O � <br />NL <br />I` > <br />a� <br />r 0 <br />> T_ <br />O <br />0U <br />.0 <br />m <br />Z <br />W 0-4 <br />>o <br />o <br />Z <br />J <br />C <br />E <br />01 <br />e!J <br />0 <br />N <br />rn <br />N <br />4 <br />O <br />N r— <br />(Q <br />V <br />Q <br />LU <br />ce <br />M� <br />W <br />T11 <br />O <br />O <br />N <br />O I— <br />>_ (n O o <br />cM O <br />Q w (M � <br />LL d' <br />QL1JQ�? <br />�wO..c'M <br />Q V Q O <br />Z > I— <br />w <br />_1 O <br />O <br />IT <br />Z Z <br />- <br />ZO <br />owa) <br />UI~-� <br />O Lj <br />0f W <br />n- = Q <br />w F_ <br />m0z <br />1— = Z <br />Z 3: J <br />Z 2W <br />a-w <br />W Z Z <br />z<0 <br />LAST PLOT DATE <br />Oct. 10, 17 <br />1 ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />A <br />a <br />z <br />z <br />w <br />J <br />0 <br />0 U <br />